## Page 1
# 25 Code GTO Digital Keypad
## Instructions for Wired and Wireless Installations
> Figure: Photograph of the GTO digital keypad. Black vertically oriented keypad with buttons labeled `1 2 3`, `4 5 6`, `7 8 9`, and `0`; a circular button or indicator is at lower left and a small indicator is at lower right.
Thank you for purchasing the GTO Digital Keypad. Be sure to read the directions carefully and completely. Before permanently mounting the keypad, please program the keypad and test its range.
IMPORTANT: Your keypad may need to be hard wired due to the fact that it must accept interference according to FCC regulations listed below. For example, applications that are relativity close to cell towers or airports may receive intermittent interference and require hard-wiring.
The GTO Digital Keypad is a multipurpose keypad that can work with other applications in addition to GTO gate openers and locks. As a wired keypad it can operate garage door openers and gate openers, that require 24 volts or less and accept normally open contacts. As a wireless keypad it can be used with any gate or garage door opener that receives a 318 MHz RF signal. The keypad must be used in conjunction with the GTO garage door receiver kit (part # RB709) on any other garage door.
SAFETY NOTE: Never install the keypad where a person can reach through the gate to activate it, or where a person can touch the gate while activating the keypad. The recommended minimum distance between the gate and keypad is 10 ft.
> FCC WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
>
> NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
## Page 2
# Keypad Description
> Figure: Front view of keypad. Labels and arrows identify:
>
> - **PROGRAM button:** Used to program access codes.
> - **STATUS Light:** This led will blink once when any key is pressed and provides visual feedback during access code programming.
>
> Keypad buttons shown: `1`, `2 ABC`, `3 DEF`, `4 GHI`, `5 JKL`, `6 MNO`, `7 PRS`, `8 TUV`, `9 WXY`, `0`.
### Keypad - Front
> Figure: Inside view of keypad with control board, battery compartment, and labeled arrows.
>
> - **DIP Switches:** Match these switches to your remote transmitter to program the keypad. DIP switches are numbered `1 2 3 4 5 6 7 8 9`, with `+`, `0`, and `–` position markings.
> - **Power Input:** Used to connect power supply (8-24 Vac/dc) when using outside power source.
> - **Relay output:** Used to connect Keypad to gate opener in hard-wired applications.
> - **RESET button:** Pressing this button for 2 seconds will reprogram key pad to factory settings. All codes are deleted. Default master code is 1234.
> - **Battery Holder:** Use 3 AA batteries if hard-wired power supply is not used. If external power source is used the 3 AA batteries will provide a back-up power source.
>
> Board labels visible: `RELAY OUTPUT`, `POWER IN`, and `RESET`.
### Keypad - Inside
# Installing Batteries
**NOTE:** 3 AA batteries are required to power the keypad unless an external power supply such as the gate openers power source is used. Low voltage wire from the external power source must be connected to the POWER IN terminals on the keypad control board, if batteries are not installed.
**Step 1:** Remove the two screws from the bottom of the keypad and separate the keypad from its housing.
**Step 2:** Install 3 AA batteries (not included).
# Wireless Installation of the Keypad
**NOTE:** For wireless applications, the distance from the keypad to the opener’s receiver should not exceed 50 ft. Always test the keypad range before permanently mounting it.
**Step 1:** Mount the keypad cover using the screws provided. Set the keypad DIP switches to match your entry transmitter’s DIP switch settings.
> Figure: DIP switch setting diagram. Switch positions are labeled `+`, `0`, and `–`; switches are numbered `1` through `9`.
**NOTE:** If you have not changed your opener’s transmitter code from the factory setting, see the “Setting Your Personal Transmitter Code” section in the gate openers manual then set the keypad DIP switches to match the new transmitter DIP switch setting.
**Step 2:** Slide the keypad into the cover and secure with the small screws provided.
> Figure: Two installation drawings showing the keypad mounted on a post. The left drawing shows the keypad sliding into its cover and two small screws being installed from below. The right drawing shows the rear of the keypad cover mounted to the post with two screws.
# Wired Installation of the Keypad
**NOTE:** If you also plan to power the keypad with the gate opener’s power source, run two pairs of wires as described below. One pair to hard-wire the keypad and the other pair to connect the keypad to the gate opener’s battery.
**Step 1:** Turn the gate opener’s power switch **OFF**. Use 16 gauge, stranded, direct burial low voltage wire (part no. RB509) to connect the keypad to the opener control board. Run wire through PVC pipe from the ground to keypad and from the ground to the opener control board to protect the wire from lawn mowers or grazing animals.
Determine how the wire will enter the keypad (i.e. from the back through a hole drilled in the mounting post or running the wire on the surface of the post). Remove the small rectangular knock-out on the back of the keypad cover and pull the wire into the cover. Then mount the cover to the post using the screws provided.
> Figure: Rear keypad-cover installation drawing on a post. Wires enter through the small rectangular **Knock-out** in the back of the cover. The wires route downward into PVC pipe. Two mounting screws are shown.
## Page 3
**Step 2:** To hard-wire the keypad - strip the wires back 3/16” and attach the wires to the terminal block marked RELAY OUTPUT on the keypad control board as shown to the right. Connect the other end to the opener’s control board as shown in Control Board Connections section below.
To wire the power supply to the keypad attach the wires to the AC/DC POWER IN terminal on the keypad control board as shown to the right. Connect the other end to the opener’s battery - one end to the POSITIVE pole and the other to the NEGATIVE pole.
**NOTE:** For a hard-wired application the jumper between the two terminals on the keypad control board must be connected (ON) as shown. This will disable the 318 MHz RF transmitter.
> Figure: Keypad control-board wiring diagram. The terminal blocks are labeled “RELAY OUTPUT” and “AC/DC POWER IN.” Two hard-wire leads from the gate opener connect to RELAY OUTPUT and are identified as “#1” and “#2.” Power leads from the opener battery connect to AC/DC POWER IN and are labeled “Power Supply from Opener Battery.” The hard-wire cable is labeled “Hard-wire from Gate Opener.” A keypad terminal display shows “+ 0” and terminals numbered “1 2 3 4 5 6 7 8 9.” An inset shows jumper positions labeled “Jumper OFF” and “Jumper ON,” with an arrow indicating the ON position.
> Figure: Drawing of a keypad being slid into its cover. Two small screws are shown below the keypad with upward arrows indicating installation.
**Step 3:** Slide the keypad into the cover and secure with the small screws provided.
**Step 4:** With the power to the opener turned **OFF**. Remove opener control board cover and feed enough of the low voltage keypad wire through a strain relief to reach the gate opener control board terminals.
**Step 5:** Attach the wires from the keypad to the opener control board terminal blocks as shown below.
**Step 6:** Replace the control board cover and turn the power switch ON. Test the keypad by entering 1 2 3 4.
**Step 7:** Program your ‘Personal Master Code’ and any additional entry codes (for a total of 25 entry codes) you wish. See Programming the Keypad section.
# Control Board Connections
**NOTE:** If your control board doesn’t look like any of these diagrams, please call GTO Technical Service at 1-800-543-1236 or 850-575-4144 for additional support.
> Figure: “Mighty Mule 250 E-Z Gate Opener Control Board” diagram. Terminal labels include “GREEN,” “BLK,” “RED,” “SAFETY EDGE,” “CYCLE,” “COMMON,” “RADIO,” “18 VAC INPUT,” “LEARN TRANSMITTER,” “SET CLOSE LIMIT,” and “15 AMP.” Wire #1 from the RELAY OUTPUT terminals on the keypad connects to the CYCLE terminal. Wire #2 from the RELAY OUTPUT terminals connects to the COMMON terminal.
> Figure: “Mighty Mule 350 Control Board” diagram. Terminal labels include “LINK,” “EXIT,” “RECR,” “EDGE,” “CYCLE,” “COM,” “GRN,” “BLK,” and “RED.” Wire #1 from the RELAY OUTPUT terminals on the keypad connects to the CYCLE terminal. Wire #2 from the RELAY OUTPUT terminals connects to the COMMON terminal.
> Figure: “Mighty Mule 500 & 502 Control Boards” diagram. Terminal labels include “COM,” “CYCLE,” “CLOSE EDGE,” “SAFETY EXIT,” “SHADOW LOOP,” “CLOSE EDGE,” “OPEN EDGE,” and “GRN BLK RED RECEIVER.” Wire #1 from the RELAY OUTPUT terminals on the keypad connects to the CYCLE terminal. Wire #2 from the RELAY OUTPUT terminals connects to the COM terminal.
> Figure: “GTO/PRO DC Powered PRO-SW3000 and PRO-SW4000 Control Boards” diagram. Labels include “J11,” “J8,” “J12,” “COM,” “CYCLE,” “CLOSE,” “SAFETY,” “EXIT/OPEN,” “SHADOW LOOP,” “CLOSE EDGE,” “OPEN EDGE,” and “GRN BLK RED RECEIVER.” Wire #1 from the RELAY OUTPUT terminals on the keypad connects to the CYCLE terminal. Wire #2 from the RELAY OUTPUT terminals connects to the COM terminal.
> Figure: “GTO/PRO AC Powered Operator Control Board” diagram. Terminal labels include “AUX 2,” “ACCES. PWR 24VDC,” “TB8,” “TB7,” “TB6,” “TB5,” “TB4,” “TB3,” “GTO RCVR.,” “CLOSE,” “OPEN,” “FIRE DEPT.,” “SHAD. LOOP,” “SAFE LOOP,” “ENTRY LOOP,” “FREE EXIT,” “CYCLE,” and “COMMON.” Wire #1 from the RELAY OUTPUT terminals on the keypad connects to the CYCLE terminal. Wire #2 from the RELAY OUTPUT terminals connects to the COMMON terminal.
## Page 4
# Programming the Keypad
## Programming Interface:
- All codes are four (4) digits in length.
- Entry code is a four (4) digit code needed to activate the gate.
- Master Code is needed to add, remove or reset entry codes.
- Master Code also functions as the entry code under normal operation.
- Factory default Master Code is 1234.
- STATUS light should blink and beeper should beep (once) whenever any button is pressed.
- If more than 10 seconds elapsed between key presses the unit returns to normal (idle) operating mode.
- Keypad can only enter program mode from sleep mode (keypad is turned OFF).
- Keypad will beep three times before going into sleep mode.
## Program New Master Code:
- Press and release PROGRAM button.
- Enter the old Master Code then press and release PROGRAM button.
- Enter 0, 6 then press and release PROGRAM button
- Enter the new Master Code then press and release PROGRAM button.
- Enter the new Master Code then press and release PROGRAM button again for confirmation.
- Beeper beeps 3 times to confirm that the new Master Code is accepted.
**NOTE:** If the Master Code is not a matched pair or error occurs (i.e. if the entry code is NOT a 4-digit code) the STATUS light will flash rapidly and the beeper will sound for 2 seconds before returning to normal operation with old Master Code.
**Example:** Key press sequence to change old Master Code from 1 2 3 4 to 3 1 2 1
> Figure: Key-press sequence diagram. Circular black PROGRAM-button symbols appear before the sequence, after `1 2 3 4`, after `0 6`, after the first `3 1 2 1`, and at the end. Number keys are shown in outlined squares: PROGRAM, `1 2 3 4`, PROGRAM, `0 6`, PROGRAM, `3 1 2 1`, PROGRAM, `3 1 2 1`, PROGRAM. Caption: “The round black dot is the ‘PROGRAM’ button.”
## Program (Add) New Entry Code:
- Press and release PROGRAM button.
- Enter the Master Code then press and release PROGRAM button.
- Enter 0, 2 then press and release PROGRAM button.
**NOTE:** If memory is full (all 25 locations are already programmed) the STATUS light will flash rapidly and the beeper will sound for 2 seconds before returning to normal operation, without saving.
- Enter the new Entry Code then press and release PROGRAM button.
- Beeper beeps 3 times to confirm that the new Entry Code is accepted.
**NOTE:** If the code is NOT 4-digits in length or an error condition has occurred, the STATUS light will flash rapidly and the beeper will sound for 2 seconds before returning to normal operation, without saving.
**Example:** Key press sequence to add ‘3456’ as a new entry code. (1234 is the Master Code)
> Figure: Key-press sequence diagram. Circular black PROGRAM-button symbols separate groups of outlined number keys: PROGRAM, `1 2 3 4`, PROGRAM, `0 2`, PROGRAM, `3 4 5 6`, PROGRAM. Caption: “The round black dot is the ‘PROGRAM’ button.”
## Program (Add) New Temporary Entry Code:
- Press and release PROGRAM button.
- Enter the Master Code then press and release PROGRAM button.
- Enter 8, and any number between 1 thru 7 then press and release the PROGRAM button. The second number indicates the number of days after which the code will be automatically removed from memory
**NOTE:** If memory is full (all 25 locations are already programmed) or an invalid entry is detected then an error condition has occurred, the STATUS light will flash rapidly and the beeper will sound for 2 seconds before returning to normal operation, without saving.
- Enter the new Entry Code then press and release PROGRAM button.
- Beeper beeps 3 times to confirm that the new Entry Code is accepted.
**NOTE:** If the code is NOT 4-digit in length or an error condition has occurred, the STATUS light will flash rapidly and the beeper will sound for 2 seconds before returning to normal operation, without saving.
**Example:** Key press sequence to add “3456” as a new entry code that will remain valid for 2-days only. (1234 is the Master Code)
> Figure: Key-press sequence diagram. Circular black PROGRAM-button symbols separate groups of outlined number keys: PROGRAM, `1 2 3 4`, PROGRAM, `8 2`, PROGRAM, `3 4 5 6`, PROGRAM. Caption: “The round black dot is the ‘PROGRAM’ button.”
**Example:** Key press sequence to add “3456” as a new entry code that will remain valid for 7-days only. (1234 is the Master Code)
> Figure: Key-press sequence diagram. Circular black PROGRAM-button symbols separate groups of outlined number keys: PROGRAM, `1 2 3 4`, PROGRAM, `8 7`, PROGRAM, `3 4 5 6`, PROGRAM. Caption: “The round black dot is the ‘PROGRAM’ button.”
## Delete An Entry Code:
- Press and release PROGRAM button.
- Enter the Master Code then press and release PROGRAM button.
- Enter 0, 3 then press and release PROGRAM button.
- Enter the Entry Code to be deleted then press and release PROGRAM button.
- Beeper beeps 3 times to confirm that the new Entry Code is deleted.
**NOTE:** If no matching code is found or the code is NOT 4-digit in length then an error condition has occurred, the STATUS light will flash rapidly and the beeper will sound for 2 seconds before returning to normal operation, without saving.
**Example:** Key press sequence to delete entry code ‘3456’ from memory. (1234 is the Master Code)
> Figure: Key-press sequence diagram. Circular black PROGRAM-button symbols separate groups of outlined number keys: PROGRAM, `1 2 3 4`, PROGRAM, `0 3`, PROGRAM, `3 4 5 6`, PROGRAM. Caption: “The round black dot is the ‘PROGRAM’ button.”
## Page 5
### Delete ALL Entry Codes:
- Press and release PROGRAM button.
- Enter the Master Code then press and release PROGRAM button.
- Enter 0, 7 then press and release PROGRAM button.
- Beeper beeps 3 times to confirm that the All Entry Codes are deleted.
**Example:** Key press sequence to delete all entry codes from memory. (for example if 3121 is the Master Code)
> Figure: Key press sequence showing a round black PROGRAM button symbol, followed by boxed keys “3”, “1”, “2”, “1”, then a round black PROGRAM button symbol, boxed keys “0” and “7”, and a final round black PROGRAM button symbol. The round black dot is the ‘PROGRAM’ button.
### Normal Keypad Operation:
- If the user enters a 4-digit code that is matched to one of the 25 stored codes. The STATUS light should blink twice and the beeper should beep twice to confirm that a matched code is entered.
- No more than 20 key presses are allowed to obtain the 4-digit entry code.
**Example:**
1234 is one of the codes stored in one of the memory location.
The user can enter ‘x1234’ or ‘xxxxxxxxxxxxxxxx1234’ and the gate should be activated (x is any key). If more than 20 key presses is entered without matching one of the codes then the unit’s STATUS light should be flashing rapidly and no entry will be accepted for the next 40 seconds. The user must not enter any code for at least 40 seconds before the unit returns to normal operation; otherwise it remains in this ‘lock-down’ mode. Once the user enters a matched code, any subsequent key press within the next 40 seconds will re-activate the keypad.
### Keying Indication Summary:
| | Keying Error Alert Indication | Keying accepted confirmation Indication |
|---|---|---|
| Master Code Setting | Speaker: continuous Beep for 2 seconds<br>STATUS light: rapid flashing | Speaker: Beep – Beep – Beep<br>STATUS light: no light, no flashing |
| Permanent Entry Code | Speaker: continuous Beep for 2 seconds<br>STATUS light: rapid flashing | Speaker: Beep – Beep – Beep<br>STATUS light: no light, no flashing |
| Temporary Entry Code Setting | Speaker: continuous Beep for 2 seconds<br>STATUS light: rapid flashing | Speaker: Beep – Beep – Beep<br>STATUS light: no light, no flashing |
| Entry Code Matching | Speaker: continuous Beep for 2 seconds<br><br>STATUS light: rapid flashing | Speaker: Beep – Beep – Beep<br>(after non-matching 20 keying)<br>STATUS light: no light, no flashing |
If you have any questions or concerns, please contact our Technical Service Department at 1-800-543-1236 or 850-575-4144.
GTO, Inc. • 3121 Hartsfield Road • Tallahassee, Florida 32303
Telephone (850) 575-0176 • Fax (850) 575-8912 • website www.gtoinc.com
The contents of all material available on this installation manual are copyrighted by GTO, Inc. (“GTO”), unless otherwise indicated. All rights are reserved by GTO, and content may not be reproduced, downloaded, disseminated, published, or transferred in any form or by any means, except with the prior, written permission of GTO. Any reprinting of GTO publications is by permission only. Copyright infringement is a violation of federal law.