Skip to main content
## Page 1 > Figure: Cover photo of a modern residence with a sliding driveway gate. Four gate operators are shown, labeled: “SL-45DC PRO,” “SL-90DC PRO,” “SL-100DC PRO,” and “SL-150DC PRO.” Large ALL-O-MATIC logo at top. QR code labeled “allomatic.net.” Red panel reads “BLDC PRO” and “SLIDER MANUAL.” Image of a control board labeled “ALL-BLDC PRO”; smaller board labels are mostly illegible. Bottom text: “EACH INCLUDE: 2 Chain Bolts | 20 ft of Dacromet Chain | 2 Chain Brackets | 2 RED EYE Photoeye.” Bottom banner includes ALL-O-MATIC logo, “SLIDERS | SWINGERS | OVERHEADS,” US flag, “allomatic.net,” UL Certified mark “SAFETY US-CA SÛRETÉ US-CA E543801,” and: “The widest selection of AC & DC Gate Operators for all your residential and commercial installations.” ## Page 2 [illegible] ## Page 3 [illegible] ## Page 4 Table of Contents **Safety and Introduction** - Safety Instructions .................................................. 1–2 - UL 325 Class Types .................................................. 3 - Operator Specifications .............................................. 4–5 **Installation** - SL-45 DC Concrete Pad Installation ................................... 6 - SL-90 DC Concrete Pad Installation ................................... 7 - SL-100 DC [FP] Concrete Pad Installation ............................. 8 - SL-150 DC Concrete Pad Installation .................................. 9 - Front and Rear Mount Installation .................................... 10–12 - Electrical Wiring .................................................... 13 - Wire Size Chart ...................................................... 14 - Gate Opening Direction & Travel Adjustment ........................... 15 **Board Features & Clutch Adjustment** - Dip-Switch Functions ................................................ 16 - Auto Close Timer Setting & Receiver Wiring ........................... 17 - Gate Force Adjustment ................................................ 18 - Clutch Torque Adjustment ............................................. 19 - Primary/Secondary Setup & Wiring ..................................... 20 - Auxiliary Relay & Leaf Delay Setting ................................. 21 **Accessory Installation** - Entrapment Protection Installation ................................... 22–25 - Ground Loop Layout ................................................... 26 - Plug-in Detector Installation ........................................ 27 - Accessory Wiring ..................................................... 28 - 3-Button Station & Maglock/Solenoid Wiring ........................... 29 - Solar Panel Wiring ................................................... 30–31 - LED Diagnostics ...................................................... 32 - Technical Troubleshooting ............................................ 33 - AUX Inputs Programming ............................................... 34 - LCD Display Settings & Diagnostics ................................... 35–36 **Emergency Release Instructions** - Emergency Release – SL-45DC PRO ...................................... 39 - Emergency Release .................................................... 40 **Accessories and Parts Breakdown** - Pad Lock Tabs ........................................................ 41 - Blowout Drawing ...................................................... Check Website **Warranty and Customer Record** - Warranty and Customer Record ......................................... 42 ## Page 5 IMPORTANT SAFETY INSTRUCTIONS # WARNING TO REDUCE THE RISK OF INJURY: **READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.** Do not start installation until you have read and fully understand these directions. If there is something you do not understand, please call us. **General Safety** - **Never** let children operate or play with gate controls. - Locate the control station: 1. Within sight of the gate. 2. At a minimum height of 5 feet, so small children cannot reach it. - Install the enclosed **entrapment warning signs** next to the control station and in a prominent location. **Manual Release** - For operators equipped with a manual release: - Instruct the end user on correct operation. - Use the manual release only when the gate is not moving. - It is advised that power be turned off before use. **Operation and Testing** - Always keep people and objects away from the gate. - **No one should cross the path of a moving gate.** - The gate operator must be **tested monthly:** - The gate must reverse on contact with a rigid object, or - Stop when an object activates the non-contact sensor(s). - Always re-test the operator after adjusting the limits and/or force. - Failure to properly adjust and re-test may cause **severe injury or death.** **Maintenance and Service** - Keep gate(s) properly maintained. - Have a **qualified service technician:** - Make repairs to gate hardware. - Perform adjustments to the gate operator. - This gate entrance/exit is for **vehicles only.** Pedestrians must use a separate entrance. - There is nothing on a gate operator that can be easily repaired or adjusted without training. Call a **qualified gate service technician** who knows your gate operator. SAVE THESE INSTRUCTIONS ## Page 6 IMPORTANT SAFETY INSTRUCTIONS (CONTINUED) # INSTALL THE GATE OPERATOR ONLY WHEN YOU # HAVE READ THE FOLLOWING ## BEFORE GATE OPERATOR INSTALLATION - Confirm that the gate operator being installed is appropriate for the application. - Confirm that the gate is designed and built according to the current published industry standards. - Confirm that all appropriate safety features and safety accessory devices are being installed, including all entrapment protection devices. - Make sure that the gate opens and closes freely (by hand) before installing the operator. - Repair or replace worn or damaged gate hardware before installing the gate operator. - Eliminate all gaps in the sliding gate below a 6 foot height that permits a 2 1/4” sphere to pass through any location. This includes the area of the adjacent fence covered when the gate is in the open position. - Eliminate all gaps in a swing gate below a 4 foot height that permits a 4” sphere to pass through any location. This includes the hinge area of the gate. - Install a proper electrical ground to the gate operator. - Controls intended for user activation must be located at least 6 feet away from any moving part of the gate, and where the user is prevented from reaching over, under, around, or through the gate to operate the controls. - Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. - The stop and/or reset button must be located in the line of sight of the gate. Activation of the operator reset control shall not cause the operator to move. - Install a minimum of 2 warning signs, one on each side of the gate where they are easily visible. - Take pictures of the installation. - Test all safety features for proper function before placing the automatic vehicular gate in operation. ## GATE OPERATOR INSTALLATION - Operator must be disconnected from the power source before attempting any installation of accessories. - Install gate operator according to the installation instructions in this manual. - Adjust the operator clutch or load sensing device to the minimum force setting that will allow for reliable gate operation. - Install the operator inside the fence line. Do not install the operator on the public side of the fence line. ## MAINTENANCE - Train owners/users on the basic functions and safety features of the gate system, including how to turn off the power and operate the manual disconnect feature. - Leave safety instructions, product literature, installation manual, and maintenance manual with the owner or end user. - Explain to the owner or end user the importance of routine service and operator testing on a monthly basis. ## Page 7 UL 325 CLASS TYPES AND OBSTRUCTION SENSING SYSTEMS Each class must have (2) monitored entrapment protection devices in each entrapment zone to sense and react to obstructions within 2 seconds. All-O-Matic’s gate operators conform to the most rigid Class One. ## UL 325 CLASS TYPES **CLASS ONE: RESIDENTIAL** - A vehicular gate operator intended for use in garages or parking areas associated with a residence of one to four single families. **CLASS TWO: COMMERCIAL OR GENERAL PUBLIC ACCESS** - A vehicular gate operator intended for use at a commercial location or building, such as a multi-family housing unit (five or more single family units), hotel, garages, retail stores, or other buildings accessible by or servicing the general public. **CLASS THREE: INDUSTRIAL OR LIMITED ACCESS** - A vehicular gate operator intended for use at an industrial location or building, such as a factory, loading dock area, or other locations not accessible by or intended to service the general public. **CLASS FOUR: RESTRICTED ACCESS** - A vehicular gate operator intended for use at a guarded industrial location or building, such as airport security areas or other restricted access locations not servicing the general public and where unauthorized access is prevented via supervision by security personnel. ## THE SIX TYPES OF OBSTRUCTION SENSING SYSTEMS **TYPE A:** - Inherent entrapment protection system. This system must sense and initiate the reverse of the gate within 2 seconds of contact with a solid object. **TYPE B1:** - Non-contact sensor (photoelectric sensor or equivalent). This system shall, upon sensing an obstruction in the direction of the gate travel, reverse the gate within a maximum of 2 seconds. **TYPE B2:** - Contact sensor (edge device or equivalent). This system shall, upon sensing an obstruction in the direction of the gate travel, initiate the reversal of the gate within a maximum of 2 seconds. **TYPE C:** - Inherent force limiting, inherent adjustable clutch, or pressure relief valve. **TYPE D:** - Actuating device requiring continuous pressure to maintain opening or closing motion of the gate. > Figure: UL Certified mark with “UL” inside a circle; vertical text “CERTIFIED”; labels “SAFETY US-CA,” “SÛRETÉ US-CA,” and “E543801”; QR code. ## Page 8 OPERATOR SPECIFICATIONS | | SL-45DC PRO | SL-90DC PRO | |---|---|---| | **Max Gate Weight** | 800 lbs. | 1,600 lbs. | | **Max Gate Length** | 30 feet | 50 feet | | **Warranty** | 5 year residential | 7 year residential<br>5 year commercial | | **Motor** | 24 VDC brushless with planetary gearbox | 24 VDC brushless<br>1/2 HP motor | | **Gate Speed** | 12” per second | 12” per second | | **Power Options** | 120 VAC 50/60Hz single phase - 2 amps<br>208/240 VAC 50/60Hz single phase - 1 amp<br>24 VDC solar panel up to 80 watts | 120 VAC 50/60Hz single phase - 4 amps<br>208/240 VAC 50/60Hz single phase - 2 amps<br>24 VDC solar panel up to 80 watts | | **Duty Cycle** | Continuous | Continuous | | **Temperature Range** | -40° to 160° | -40° to 160° | | **Gearbox Ratio** | Approx. 20:1 | 20:1 with internal disconnect | | **Width X Length X Height** | 11” W X 14.5” L X 15.5” H | 15.5” W X 18.5” L X 16” H | | **Shipping Weight** | 60 lbs. | 95 lbs. | | **Emergency Release** | Push open in the event of a power failure | Mechanical foot pedal release | | **Belt Size** | N/A | 4L-230 (AX21) | | **Main Sprocket Size** | 41B15X5/8 | 41B22X7/8 | | **Chain Size** | 41RF (20’ included) | 41RF (20’ included) | | **Gearbox Sprocket** | 41B10X5/8” | 41B12X7/8 | | **Limit Shaft Sprocket** | 41B10X5/8” | 41B15X5/8 | | **Breaker Requirement** | 20 amp dedicated | 20 amp dedicated | | **Gearbox Pulley** | N/A | 2 1/2” with 5/8” bore | | **Motor Pulley** | N/A | 2” with 5/8” bore | | **UL Classes** | I & II | I, II, III & IV | ## Page 9 OPERATOR SPECIFICATIONS (CONTINUED) | | SL-100DC PRO | SL-150DC PRO | |---|---|---| | Max Gate Weight | 2,000 lbs. | 1/2 HP: 3,000 lbs.<br>1 HP: 4,000 lbs. | | Max Gate Length | 50 feet | 60 feet | | Warranty | 7 year residential<br>5 year commercial | 7 year residential<br>5 year commercial | | Motor | 24 VDC brushless<br>1/2 HP motor | 24 VDC brushless<br>1/2 and 1 HP motor | | Gate Speed | 12” per second | 12” per second | | Power Options | 120 VAC, 50/60Hz single phase – 6 amps<br>208/240 VAC, 50/60Hz single phase – 3 amps<br>24 VDC solar panel up to 80 watts | 120, 208/240 VAC, 50/60Hz single phase<br>1/2 HP: 6/3.5 amps, 1 HP: 8/4.5 amps<br>24 VDC solar panel up to 80 watts | | Duty Cycle | Continuous | Continuous | | Temperature Range | -40° to 160° | -40° to 160° | | Gearbox Ratio | 20:1 with internal disconnect | 30:1 with internal clutch | | Width X Length X Height | 12” W X 17.5” L X 23.5” H | 15” W X 19.5” L X 25” H | | Shipping Weight | 130 lbs. | 150 lbs. | | Emergency Release | Mechanical foot pedal release | Mechanical foot pedal release | | Belt Size | 4L-260 (AX24) | N/A | | Main Sprocket Size | 41B22X7/8 | 40B22X1 | | Chain Size | 41RF (20’ included) | 40RF (20’ included) | | Gearbox Sprocket | 41B12X7/8 | 40B22X1 | | Limit Shaft Sprocket | 41B15X5/8 | 41B10X5/8 | | Breaker Requirement | 20 amp dedicated | 20 amp dedicated | | Gearbox Pulley | 2 1/2” with 5/8” bore | N/A | | Motor Pulley | 2” with 5/8” bore | N/A | | UL Classes | I, II, III & IV | I, II, III & IV | ## Page 10 SL-45DC PRO CONCRETE PAD > Figure: Concrete-pad installation drawing with **TOP VIEW** and **FRONT VIEW**. Top view shows track footing, gate track, gate, chain, operator frame, operator concrete pad, and area for conduit. Track footing is labeled **10”** deep; clearance is **MINIMUM 5”**. Operator-frame-related dimensions shown are **3”**, **8.5”**, **11”**, **24”**, **10”**, and **8.5”**. Operator concrete pad is dimensioned **24”** by **24”**. Four anchor locations are called out as **4 RED HEAD BOLTS 1/2” X 3 1/2”**. Front view shows operator machinery, chain, track footing, gate-operator footing, and two conduits. Labels and dimensions include **TOTAL COVER HEIGHT**, **15.5”**, **10.25”**, **6”**, **3.75”**, **INSTALL 4” ABOVE GROUND (WHEN POSSIBLE)**, **4”**, **8”**, and footing depth **24”**. Arrows identify **LOW VOLTAGE CONDUIT** and **HIGH VOLTAGE CONDUIT**. ## Page 11 SL-90DC PRO CONCRETE PAD > Figure: Concrete-pad installation drawing with **TOP VIEW** and **FRONT VIEW**. Top view shows **TRACK FOOTING**, **GATE TRACK**, **GATE**, **OPERATOR PLASTIC COVER**, **AREA FOR CONDUIT(S)**, and **OPERATOR CONCRETE PAD**. Track footing is labeled **10”** deep, and clearance is **MINIMUM 5”**. Dimensions shown include **2.25”**, **10.5”**, **18”**, **24”**, **13.5”**, **15”**, and **24”**. Four anchor locations are called out as **4 RED HEAD BOLTS 1/2” X 3 1/2”**. Front view shows the operator mechanism and chain above the pad, track footing, gate-operator footing, and conduits. Labels and dimensions include **TOTAL COVER HEIGHT**, **16”**, **11.5”**, **7”**, **4.5”**, **INSTALL 4” ABOVE GROUND WHEN POSSIBLE**, **4”**, **8”**, and footing depth **24”**. Arrows identify **LOW VOLTAGE CONDUIT** and **HIGH VOLTAGE CONDUIT**. ## Page 12 SL-100DC PRO CONCRETE PAD > Figure: Concrete-pad installation drawing with **TOP VIEW** and **FRONT VIEW**. Top view shows **TRACK FOOTING**, **GATE TRACK**, **GATE**, **CHAIN LINE**, **OPERATOR PLASTIC COVER**, **OPERATOR FRAME**, **AREA FOR CONDUIT**, and **OPERATOR CONCRETE PAD**. Track footing is labeled **10”** deep, and clearance is **MINIMUM 5”**. Dimensions shown include **2.5”**, **10”**, **17”**, **24”**, **9.5”**, **12.25”**, and **24”**. Four anchor locations are called out as **4 RED HEAD BOLTS 1/2” X 3 1/2”**. Front view shows the operator mechanism and chain above the concrete footing. Labels and dimensions include **13.5”**, **23.5”**, **6.5”**, **4.5”**, **INSTALL 4” ABOVE GROUND (WHEN POSSIBLE)**, **4”**, **8”**, **TRACK FOOTING**, **FOOTING FOR GATE OPERATOR**, and footing depth **24”**. ## Page 13 SL-150DC PRO CONCRETE PAD TOP VIEW > Figure: Top-view concrete pad diagram. A gate runs on a labeled **GATE TRACK** over **TRACK FOOTING**. Track footing dimension is **10"**. The operator footing is shown below the track, with a dashed **CHAIN LINE**. Labels and dimensions: **MINIMUM 5"**, **1.75"**, **7.5"**, **15"**, **24"**, **16.25"**, **20"**, and **30"**. Four anchor locations are called out as **4 RED HEAD BOLTS ½" X 3 ½"**. Arrows identify an **AREA FOR CONDUIT** within the operator footing. FRONT VIEW > Figure: Front-view diagram of the SL-150DC PRO operator on a concrete footing beside the track. The track is labeled **TRACK**. Dimensions shown include **10"**, **25"**, **6"**, **3"**, **4"**, **8"**, and **24"**. An arrow notes **INSTALL 4" ABOVE GROUND (WHEN POSSIBLE)**. The concrete block is labeled **FOOTING FOR GATE OPERATOR**. ## Page 14 FRONT MOUNT INSTALLATION FRONT VIEW > Figure: Front-view installation diagram. A sliding gate is shown in solid lines when closed and dashed lines when open. Labels: **GATE IN OPEN POSITION**, **GATE CLOSED**, **OPERATOR FOOTING**, **GATE OPERATOR**, and **TRACK FOOTING**. The operator is installed at the front side of the gate opening, adjacent to the operator footing. OVERHEAD VIEW > Figure: Overhead-view diagram showing the track footing extending beneath the gate path and driveway. Labels: **TRACK FOOTING**, **OPERATOR FOOTING**, and **DRIVEWAY**. The operator footing is shown at the gate/operator location. ## Page 15 FRONT MOUNT INSTALLATION (CONTINUED) SL-45DC PRO > Figure: Side/profile diagram of the SL-45DC PRO above the operator pad, showing sprockets and drive chain. Labels: **TOTAL COVER HEIGHT**, **DRIVE CHAIN LEVEL**, and **TOP OF OPERATOR PAD**. Dimensions shown: **15.5"** total cover height and **6"** from the top of operator pad to drive chain level. SL-90DC PRO > Figure: Side/profile diagram of the SL-90DC PRO above the operator pad, showing sprockets and drive chain. Labels: **TOTAL COVER HEIGHT**, **DRIVE CHAIN LEVEL**, and **TOP OF OPERATOR PAD**. Dimensions shown: **16"** total cover height and **6.5"** from the top of operator pad to drive chain level. SL-100DC PRO > Figure: Side/profile diagram of the SL-100DC PRO above the operator pad, showing sprockets and drive chain. Labels: **TOTAL COVER HEIGHT**, **DRIVE CHAIN LEVEL**, and **TOP OF OPERATOR PAD**. Dimensions shown: **23½"** total cover height and **6.5"** from the top of operator pad to drive chain level. SL-150DC PRO > Figure: Side/profile diagram of the SL-150DC PRO above the operator pad, showing motor cover, sprockets, and drive chain. Labels: **TOTAL COVER HEIGHT**, **DRIVE CHAIN LEVEL**, and **TOP OF OPERATOR PAD**. Dimensions shown: **25"** total cover height and **6"** from the top of operator pad to drive chain level. ## Page 16 REAR MOUNT INSTALLATION FRONT VIEW > Figure: Front-view rear-mount installation diagram. A sliding gate is shown solid when closed and dashed when open. Labels: **GATE IN OPEN POSITION**, **GATE CLOSED**, **GATE OPERATOR**, **OPERATOR FOOTING**, and **TRACK FOOTING**. The operator is positioned at the rear side of the gate opening. OVERHEAD VIEW > Figure: Overhead-view diagram showing the operator footing at the left end of the track footing. Labels: **OPERATOR FOOTING**, **DRIVEWAY**, and **TRACK FOOTING**. CHAIN CONNECTION TO GATE > Figure: Diagram showing the chain connection from the gate operator to the gate. The chain path runs from the operator idlers toward the gate post and gate. Labels: **MOVE ONE IDLER TO THE BOTTOM CENTER HOLE AND FOLLOW THE CHAIN PATH AS SHOWN**, **CHAIN PATH**, **SAFETY GUARD**, **GATE**, **FRONT IDLER**, **GATE POST**, and **GATE OPERATOR FOOTING**. Arrows indicate the chain routing between the operator, front idler, and gate connection. ## Page 17 # AC POWER ELECTRICAL WIRING ⚡ **OPERATORS MUST BE PROPERLY GROUNDED!** ⚡ ### Grounding - All gate operators **MUST** be properly grounded. Proper grounding minimizes or prevents damage caused by electrical charges, such as lightning strikes or static discharges. - Use a **single, continuous ground wire**. - Do not splice two wires together. - If the ground wire is cut or broken, replace it with a new single-length wire. - Never use two separate wires for the ground. - Check local city code for: - Approved earth ground rod type. - Proper grounding procedures. Correct grounding is critical for lightning protection on the control board. ### Power Wiring - Use **UL-listed conduit** for enclosing all power wires. - Operators can be powered from **115VAC or 230VAC single phase**. - On the EMI board, use the **voltage selector switch** to match the correct voltage option. - Refer to the **wiring table** below for incoming power connections. - Provide a **dedicated 20A minimum circuit** for each operator. - Refer to the **current draw table** to determine the proper power wire size. | DC PRO Gate Operators | Current Draw @120VAC | Current Draw @208/240VAC | |---|---:|---:| | SL-45DC PRO | 2 Amps | 1 Amp | | SL-90DC PRO | 4 Amps | 2 Amps | | SL-100DC PRO | 6 Amps | 3.5 Amps | | SL-150DC PRO – ½ HP | 6 Amps | 3.5 Amps | | SL-150DC PRO – 1 HP | 8 Amps | 4.5 Amps | > Figure: Illustration of a power board inside an operator enclosure. An arrow labeled “POWER BOARD” points to a red circuit board. Board terminals are labeled “GRD,” “LINE 2,” and “LINE 1.” Connected wires are shown in green, white, and black. Callouts identify a “10 AMP FUSE” and “POWER AND BATTERY SWITCHES.” A magnified voltage selector switch shows “230V.” Note: “When using 208/240V power, set the voltage switch to 230V.” | Power Connection | 120 VAC 50/60Hz | 208/240 VAC 50/60Hz Single Phase | |---|---|---| | LINE 1 | 120V HOT | 208/240V LINE 1 | | LINE 2 | 120V NEUTRAL | 208/240V LINE 2 | | GND | GROUND | GROUND | **CAUTION:** Before wiring high voltage, be sure to turn OFF the breaker. ## Page 18 # AC POWER ELECTRICAL WIRING (cont.) ## Power Wire Sizing & Neutral Connection ### Wire Sizing Use the **operator current draw table** (previous page) along with the **wire size tables** (below) to calculate the correct power wire size for your installation. ⚡ **It is critical to use the proper wire size** to avoid excessive voltage drop and ensure safe, reliable operation. ### Important Neutral Connection Notice Because these operators support **dual voltage (115VAC / 230VAC single phase)**, the receptacle neutral is handled differently: - **115VAC Operation** - The **white receptacle neutral wire** must be connected to the **neutral wire of the EMI board**. - **230VAC Operation** - **Do not connect** the receptacle white neutral wire. - Connecting it in this mode will cause damage to devices plugged into the receptacle. Use below table to select the correct power wire size for the power run. It is important to use the correct size wire, as it is crucial to avoid voltage drops. **Max Wire Feet @ 120 Volts, 1 Phase,** **2% Max Voltage Drop** | Operator model | Volt–Amps | #14 | #12 | #10 | #8 | #6 | |---|---:|---:|---:|---:|---:|---:| | SL-45DCPRO | 240 | 225 | 350 | 550 | 900 | 1400 | | SL-90DC PRO | 480 | 120 | 175 | 280 | 450 | 720 | | SL-100DC PRO | 720 | 75 | 120 | 190 | 300 | 475 | | SL-150DCPRO 1/2 | 720 | 75 | 120 | 190 | 300 | 475 | | SL-150DC PRO 1 | 960 | 60 | 90 | 145 | 225 | 350 | **Max Wire Feet @ 240 Volts, 1 Phase,** **2% Max Voltage Drop** | Operator model | Volt–Amps | #14 | #22 | #10 | #8 | #6 | |---|---:|---:|---:|---:|---:|---:| | SL-45DC PRO | 240 | 450 | 700 | 1100 | 1800 | 2800 | | SL-90DC PRO | 480 | 240 | 350 | 560 | 900 | 1440 | | SL-100DC PRO | 720 | 150 | 240 | 380 | 600 | 950 | | SL-150DCPRO 1/2 | 720 | 150 | 240 | 380 | 600 | 950 | | SL-150DC PRO 1 | 960 | 120 | 180 | 290 | 450 | 700 | ## Page 19 # GATE OPENING DIRECTION AND # TRAVEL ADJUSTMENT > Figure: Close-up of an ALL-BLDC PRO control board. An arrow labeled “DIP-SWITCHES” points to the DIP switch bank. The DIP switch labels visible include: “TIMER,” “RADIO,” “OSC,” “FAIL SC/SF,” “ONE PASS,” “SECONDARY,” “AUTO OPEN,” and “OPEN L/R.” A callout points to LEDs and states: “LED indicators will indicate opening or closing when the gate is in motion.” The LED labels include “MODE,” “OPENING,” “OPEN LIMIT,” “CLOSING,” “CLOSE LIMIT,” “AUX-IN 1,” and “AUX-IN 2.” ## Gate Opening Direction Use the **OPEN L/R dip-switch (#8)** to change the operator’s opening direction. - The opening direction is determined **while standing behind the gate operator**. - LEDs will display the **opening and closing direction** when the gate is moving. ### Dip-Switch Settings - **OPEN L/R OFF** – Left-hand opening - **OPEN L/R ON** – Right-hand opening > Figure: Diagram of a double sliding gate between two posts. The left side is labeled “OPEN TO THE RIGHT” with a large arrow pointing right. The right side is labeled “OPEN TO THE LEFT” with a large arrow pointing left. A central gate operator is shown below the gate. # LIMIT TRAVEL ADJUSTMENT Locate the limit switches (limit switches will be in the limit box on SL-150DC PRO) and follow the steps below: 1. Turn the power **OFF** on the operator. 2. Press the limit lock plate down (on the SL-45 DC, SL-90 DC, and SL-100 DC) or outwards (on the SL-150 DC) 3. Turn the limit nut toward the switch to DECREASE travel and away from the switch to INCREASE travel. 4. Place limit plate back to its locked position. (**MUST** be done for gate to hold its limits) 5. Turn the power **ON** to the operator. 6. Run the gate operator open and close. If additional adjustment is needed, repeat the steps. 7. When limits are set, move the gate to the closed position. Press and release “RESET” on the circuit board and run the gate one uninterrupted cycle (full open and full close) to learn the slow down. ### SL-150DC PRO > Figure: Diagram of an SL-150DC PRO limit assembly. Labels identify “LIMIT SWITCH,” “LIMIT NUTS,” and “LIMIT NUT LOCK PLATE.” Arrows point to the limit switch and two threaded limit nuts. Text states: “EACH NOTCH EQUALS ABOUT 1/2” OF TRAVEL.” A screwdriver is shown pressing the lock plate. ### SL-45DC PRO, SL-90DC PRO & SL-100DC PRO > Figure: Diagram of a limit assembly with two limit nuts on a threaded shaft. Labels identify “LIMIT NUTS” and “LIMIT NUT LOCK PLATE.” Text states: “EACH NOTCH EQUALS ABOUT 1/2” OF TRAVEL.” Arrows point to the limit nuts and lock plate. ## Page 20 # DIP SWITCH FUNCTIONS ## TIMER - **ON** – Activates the automatic close timer. *(See TIMER page for details.)* ## RADIO - **ON** – Allows the radio receiver to override the automatic close timer. *(See TIMER page for details.)* ## OSC (Open/Stop/Close) - **ON** – Allows the radio receiver to stop and reverse the gate at any point. - First signal: **Stops** the gate. - Second signal: **Reverses** the gate. ## FAIL SC / SF - **ON (Fail-Safe):** On power failure, the board monitors battery voltage to ensure the gate opens before the battery drains completely. - **OFF (Fail-Secure):** On power failure, the gate runs until the battery is low, then locks closed. ## 1-PASS - **ON** – Enables one-pass anti-tailgating using a safety loop. - Gate opens and immediately closes once vehicle clears Safety loop. - Gate stops if a second vehicle is detected. Waits until vehicle clears the Safety loop, then continues to close. - A second vehicle must present valid credentials before entry. ## SECONDARY - For **dual gate applications**: - **ON** – Set on the **secondary operator** only. (all other dip-switches OFF, except OPEN L/R). - **OFF** – Set on the **primary operator** ## AUTO OPEN - **ON** – Automatically opens the gate after a power interruption. *(Required in some fire department jurisdictions.)* - Includes a **45-second delay** between power loss and gate opening. ## OPEN L/R - **ON** – Right-hand opening. - **OFF** – Left-hand opening. > Figure: Illustration of an eight-position DIP-switch bank. Switches are numbered 1 through 8. The labels alongside are “TIMER,” “RADIO,” “OSC,” “FAIL SC/SF,” “1-PASS,” “SECONDARY,” “AUTO OPEN,” and “OPEN L/R.” The switch orientation is labeled “OFF↔ON,” with “OPEN” printed vertically beside the switch bank. > Figure: Detailed illustration of an ALL-BLDC PRO control board. An arrow points from the DIP-switch illustration to the DIP-switch bank on the board. Readable board labels include “ALL-BLDC PRO,” “24VDC,” “12 VDC,” “+12/24VDC RADIO,” “RESET,” “OPEN,” “STOP,” “CLOSE,” “FIRE ACCESS,” “PHAN LOOP,” “SAFETY LOOP,” “MON +24VDC,” “AUX INPUT 1,” “AUX INPUT 2,” “TIMER,” “RADIO,” “OSC,” “FAIL SC/SF,” “ONE PASS,” “SECONDARY,” “AUTO OPEN,” “OPEN L/R,” “USB/OBD,” “FIRMWARE UPDATES,” “MOTOR SENSOR,” “MODE,” “OPENING,” “OPEN LIMIT,” “CLOSING,” “CLOSE LIMIT,” “AUX-IN 1,” “AUX-IN 2,” “PAIRING/ACTIVITY,” “LINE-IN,” “BATTERY,” and “FUSE->.” An arrow points to the reset button. > Figure: Note box connected by an arrow to the main reset button: “NOTE: After making any changes to the dip-switches, press the MAIN RESET button to apply and recognize the changes.” ## Page 21 # AUTO CLOSE TIME SETTING & # RADIO RECEIVER WIRING ### TIMER - **ON** – Automatic close timer active. Adjustable **1–120 seconds (up to 2 minutes)**. - **OFF** – Gate operates by command only: *Push button to open, push button to close.* ### RADIO - **ON** – Overrides the timer and allows the transmitter to close the gate before the auto-close timer expires. ### OSC (Open/Stop/Close) - **ON** – Remote/transmitter controls the gate like a garage door opener: 1. Press once → Gate starts moving. 2. Press again → Gate stops. 3. Press a third time → Gate reverses. ### Timer Adjustment Procedure 1. Set the **TIMER dip-switch** to **ON**. 2. Press the **TIMER push button** to open the **TIMER adjustment** in the LCD display. 3. Use the **UP/DOWN buttons** to set the number of seconds (1–120) the gate remains open before closing automatically. 4. Press **OK** to save the setting. > Figure: ALL-BLDC PRO control board. An arrow identifies the upper-right dip-switch bank as “**TIMER, RADIO & OSC dip-switches**.” Visible dip-switch labels: TIMER, RADIO, OSC, FAIL-PASS, ONE PASS, SECONDARY, AUTO OPEN 1, AUTO OPEN 2; “OFF→ON.” An arrow identifies the lower TIMER button as “**TIMER quick access button**.” Board labels include ALL-BLDC PRO, DATA +/−, “PRESS OK TO START LCD DISPLAY,” USB/OBD, FIRMWARE UPDATES, RESET, MODE, OPEN, STOP, CLOSE, OPEN ERD, CLOSE ERD, CLOSE TIMER, and PAIRING/ACTIVITY. --- ## Radio Receiver Connections There are **two types of receivers: 3-wire and 4-wire.** ### 3-Wire Receiver - Mounts directly on the **radio receiver terminal strip** located outside of the control box. ### 4-Wire Receiver - **Relay Contact Wires** - Connect to **Terminal 1 (COMMON)** and **Terminal 2 (RELAY/RADIO)** — one wire on each terminal. - **Power Wires** - Connect **black (negative)** wire to **Terminal 1 (COMMON)**. - Connect **red (positive)** wire to **Terminal 3 (+12/24VDC)**. *(See diagram below for reference.)* ### Related Dip-Switch - **RADIO ON** – Allows the radio receiver to override the **automatic close timer**. *(See TIMER adjustment section above for details.)* > Figure: Wiring diagram for a “**4 WIRE 12-24VDC RADIO RECEIVER**” connected to an ALL-BLDC PRO controller. The receiver terminal strip has terminals numbered 3, 2, and 1. Labels identify: “**3. 12/24VDC**,” “**2. RELAY/RADIO**,” and “**1. COMMON**.” Red wire runs from receiver to terminal 3; black wire runs to terminal 1; additional gray wires connect to controller terminals. An arrow says, “**Set the jumper to select the desired voltage:**” and points to a jumper with labels 24VDC, 12 VDC, and +12/24VDC. Caption: “**Receiver Terminal Strip** — The receiver terminal strip is located outside of the control box.” ## Page 22 # ELECTRONIC REVERSING DEVICE # (ERD) ADJUSTMENT # Electronic Reversing Device (ERD) All **BLDC PRO boards** are equipped with an **Electronic Reversing Device (ERD)**. This feature causes the gate to **reverse direction when it comes into contact with an obstruction.** ### Force Setting - The reversing force depends on the **ERD force setting**. - If the gate **reverses without obstruction**, the ERD force is set **too low**. - If the gate **does not reverse on obstruction**, the ERD force is set **too high**. ### Safety Requirement - ERDs **must be adjusted** for reliable and safe operation. - A **qualified technician** shall test and adjust the ERDs **every six months**. ### Adjustment Access - Quick-access buttons are provided for **OPEN ERD** and **CLOSE ERD** adjustments. - These open directly to the adjustment menu — no need to navigate through the LCD menus. ### Adjustment Procedure #### 1. Adjust OPEN ERD - While the gate is **opening**, press and release the **OPEN ERD** button. - The **OPEN ERD adjustment** will appear on the LCD display. - Use the **DOWN button** to decrease force until the gate stops and reverses. - Increase the setting by **30% above that point**. - Example: If reversal occurred at **20%**, increase to **50%**. - This provides a buffer for reliable operation and safety. #### 2. Adjust CLOSE ERD - While the gate is **closing**, press and release the **CLOSE ERD** button. - The **CLOSE ERD adjustment** will appear on the LCD display. - Use the **DOWN button** to decrease force until the gate stops and reverses. - Increase the setting by **30% above that point**. - Example: If reversal occurred at **20%**, increase to **50%**. - This ensures reliable closing and obstruction response. ### Factory Setting - From the factory, **OPEN ERD** and **CLOSE ERD** are set to **50%**. > Figure: ALL-BLDC PRO controller board showing quick-access controls. A large arrow points upward to the two buttons labeled “OPEN ERD” and “CLOSE ERD,” with the caption “**ERD quick access buttons**.” Visible board labels include OPEN, STOP, CLOSE, ALARM, TIMER, CLOSE TIMER, OPEN ERD, CLOSE ERD, FUSE, LINE-IN, BATTERY, MOTOR SENSORS, and dip-switch labels including TIMER, RADIO, OSC, FAIL-PASS, ONE PASS, SECONDARY, AUTO OPEN 1, AUTO OPEN 2. ## Page 23 # SL-150DC PRO CLUTCH ADJUSTMENT # SL-150DC PRO Gearbox Clutch Adjustment ### Overview The **SL-150DC PRO gearbox** is equipped with an **internal clutch** that protects the operator when the gate is reversed mid-cycle. - Factory setting: **60 lbs. of torque.** - In some applications with **heavier gates**, the clutch may require adjustment to increase torque. - The clutch must be: - **Tight enough** to move the gate without slipping. - **Not over-tightened**, as the clutch also protects the operator by slipping if the gate is jammed or reversed mid-cycle. ### Adjustment Procedure 1. Use a **pipe wrench** or a **large crescent wrench** on the clutch nut. 2. Turn the nut **clockwise** to increase torque. - Adjust **½ turn at a time** until the operator can move the gate load without slipping. 3. Once the operator moves the gate reliably: - Turn the nut an **additional full turn**. - This provides enough torque for operation while still allowing the clutch to slip during reversal or obstruction. > Figure: Technical drawing of the SL-150DC PRO gearbox/operator assembly with a circular magnified inset of the gearbox interior. A red arrow points to the clutch nut in the inset. Label: “**CLUTCH NUT**.” Leader lines connect the full assembly to the magnified detail. ## Page 24 # Primary/Secondary Communication Setup ⚠ **Important:** Complete these steps **before linking Primary/Secondary communication.** ### Preparation 1. **Adjust the ERDs and limit switches** on each operator individually as stand-alone machines. *(See ERD and Limit Switch Adjustment sections for details.)* 2. On the **secondary controller**: - Set the **SECONDARY dip-switch to ON**. - Press the **RESET** button. The **ALL-BLDC PRO controller** supports two types of Primary/Secondary communication: **Wireless** and **Hard-Wired**. Accessories can be connected to **either the Primary or Secondary operator.** ### Wireless Setup 1. On the first operator: - Press and hold the **UP button**. - While holding, press and release the **RESET** button. - Continue holding **UP** until the LCD displays: - A message prompting to **SETUP the other unit**, and - The default channel (**Channel 1**). - Release the **UP** button. 2. Repeat step 1 on the **second operator**. - Confirm both units display the **same channel**. - Ensure the **SECONDARY dip-switch is ON** for the secondary operator. 3. Once both units show the same channel and correct dip-switch settings, the operators will link. - The **P/S LINK LED** will turn **ON**. ### Hard-Wired Setup 1. On the first operator: - Press and hold the **DOWN button**. - While holding, press and release the **RESET** button. - Continue holding **DOWN** until the LCD displays **WIRED MODE**. 2. Repeat step 1 on the **second operator**. - Ensure the **SECONDARY dip-switch is ON** for the secondary operator. 3. Wire the two operators according to the diagram: - Connect **DATA+ to DATA+** and **DATA- to DATA-**. 4. After wiring is complete, the operators will link. - The **P/S LINK LED** will turn **ON**. > Figure: Primary and secondary ALL-BLDC PRO controllers connected by a shielded cable. Left controller is labeled “**PRIMARY CONTROLLER**”; right controller is labeled “**SECONDARY CONTROLLER**.” The cable conductors connect DATA+ to DATA+ and DATA− to DATA−. Cable labels: “**SHIELDED CABLE**” and “**USE UL LISTED CONDUIT**.” An arrow points along the cable toward the secondary controller. At the secondary end, a shield/drain wire connects to a frame-ground symbol with label “**CONNECT SHIELD TO SLAVE OPERATOR FRAME ONLY**.” A label beside the secondary dip-switch reads: “**SECONDARY SWITCH ON ONLY ON SECONDARY BOARD**,” with “ON” in red. ## Page 25 # Relay Programming and Gate Leaf Delay > Figure: ALL-BLDC PRO control board with labeled terminals, display, buttons, LEDs, fuse, battery, line-in, and relay terminals. A wiring diagram below connects the board’s relay terminals to boxes labeled “DEVICE POWER SUPPLY” and “DEVICE.” ### Entering the LCD Display Menu 1. **Wake the Display** – Press the OK button twice. o A startup message will appear on the screen. 2. **Select Language** – Press the LEFT button to start the English menu. 3. **Access Settings** – Highlight **SETTINGS** and press **OK**. o Here you will find options such as **AUXILIARY RELAY** and **LEAF DELAY**. ### Navigation Controls - **UP/DOWN buttons** – Scroll through menu items. - **LEFT button** – Return to the previous menu. ### Relay-1 Settings The **ALL-BLDC PRO** includes a programmable relay (N.O. or N.C.) with four configurable options. **Navigation** From the LCD menu: **English → SETTINGS → AUXILIARY RELAY → OK** **Options** (an * will be displayed to the right of the selected option.) 1. **PRE-WARN SIGNAL** – Activates a strobe or alarm before the gate moves. A delay can be set. 2. **MOVING SIGNAL** – Activates whenever the gate is in motion (no delay). 3. **OPENED SIGNAL** – Activates when the gate is fully open (indicator for gate position). 4. **CLOSED SIGNAL** – Activates when the gate is fully closed (indicator for gate position). ### Delay Settings The **ALL-BLDC PRO** also provides a delay option for open or close cycles, commonly used in swing gate applications. **Navigation** From the LCD menu: **English → SETTINGS → LEAF DELAY → OK** **Adjustment** 1. **Direction** – While cursor at **DELAY CLOSE**, press OK, then use UP to toggle between **CLOSE** and **OPEN**. Press OK to confirm. 2. **Time** – Scroll to **DELAY**, press OK, then use **UP/DOWN** to set the delay (in seconds). Press OK to save. 3. **Secondary Operator** – If used, repeat the process on the secondary operator, but set the delay in the **opposite direction**. ⚠ **Important:** Only one direction (OPEN or CLOSE) can have a delay. ## Page 26 # Entrapment Protection Requirements ### Minimum Devices - A minimum of **two (2) monitored entrapment protection devices are required** for each entrapment zone. ### Definition - An **entrapment zone** is any location where a person can become trapped between a **moving gate** and a **rigid object**. ### Built-In Protection - The operator includes an **inherent entrapment protection system (ERD)**. ### External Protection - The gate operator also **requires external monitored entrapment protection devices** for each entrapment zone before operation. - Approved devices include: - **Non-contact photoelectric sensors** - **Contact edges** ### Monitoring Function - The operator cycles power to the external entrapment devices and verifies proper signals. - If correct feedback is **not received**, the gate will **not operate**. > Figure: “FRONT INSTALLATION” diagram of a sliding gate. Contact edge sensors are shown on the leading and trailing vertical edges of the gate. Photoelectric sensors are shown across the gate path. An overhead view labels “OUTSIDE PROPERTY,” “INSIDE PROPERTY,” and two shaded “ENTRAPMENT ZONE” areas. > Figure: “REAR INSTALLATION” diagram of a sliding gate. Contact edge sensors are shown on the gate edges, with photoelectric sensors at the gate path. The overhead view labels “OUTSIDE PROPERTY,” “INSIDE PROPERTY,” and shaded “ENTRAPMENT ZONE” areas. ## Page 27 # Monitored Entrapment Protection: Wiring Instructions ## OVERHEAD VIEW OF DRIVEWAY > Figure: Overhead driveway diagram. Labels include “GATE IN THE OPEN POSITION = MON_OPEN,” “DRIVEWAY = MON_CLOSE,” “PHOTOCELL PROTECTING ACROSS DRIVEWAY,” “PHOTOCELL PROTECTING REAR OPEN SLIDE,” “REFLECTOR/TX,” and shaded “ENTRAPMENT ZONE” areas. Arrows identify the photocells and reflector/transmitter positions. ## Wiring Entrapment Device to Control Board ### MON-CLOSE: Wiring a Device Across the Driveway (Close Direction) > Figure: AOM RED EYE wiring illustration. The wires are labeled: “BLUE & YELLOW to COMMON,” “BROWN,” “BLACK (N.C.),” and “WHITE (NOT USED).” The wires connect to a control-board terminal strip labeled FIRE ACCESS, COMMON, MON +24VDC, COMMON, MON_CLOSE, MON_OPEN, FP_DISABLE, COMMON, and +12VDC OUTPUT. A box states: “Wiring the AOM-RED-EYE to the Control board (Included with Operator)” with a right-pointing arrow. ### MON-OPEN: Wiring a Device Across the Driveway (Open Direction) > Figure: AOM RED EYE wiring illustration. The wires are labeled: “BLUE & YELLOW to COMMON,” “BROWN,” “BLACK (N.C.),” and “WHITE (NOT USED).” The wires connect to a control-board terminal strip labeled FIRE ACCESS, COMMON, MON +24VDC, COMMON, MON_CLOSE, MON_OPEN, FP_DISABLE, COMMON, and +12VDC OUTPUT. A box states: “Wiring the AOM-RED-EYE to the Control board (Included with Operator)” with a right-pointing arrow. ### 10K Termination Option The **ALL-BLDC PRO** supports a **10K termination alternate option**. - Connect the **10K sensor contacts** to **COMMON** and **MON-OPEN** or **MON-CLOSE**, as shown below. > Figure: Control-board terminal diagram showing wiring for “Close contact edge with 10K termination” and “Open contact edge with 10K termination.” The terminal strip labels include MON +24VDC, COMMON, MON_CLOSE, MON_OPEN, FP_DISABLE, COMMON, +12VDC OUTPUT, COMMON, +24VDC OUTPUT, COMMON, AUX INPUT 1, AUX INPUT 2, and COMMON. ### Auxiliary Inputs for Entrapment Protection - **AUX INPUT 1** and **AUX INPUT 2** can be used to connect additional **entrapment protection devices** (10K or N.C. termination). - For **N.C. devices**, power must be connected to **MON +24VDC**. - For **10K devices**, power may be connected to **+12VDC** or **+24VDC** if the device requires power. - Refer to the **LCD Display** section for input programming details. ## Page 28 # 3RD PARTY MONITORED ENTRAPMENT PROTECTION DEVICE CONNECTIONS - **Monitored Entrapment Protection Devices** ### Sensor Types To comply with **UL 325 monitored entrapment requirements**, the operator supports two sensor types: - **Non-contact sensors** (photo eyes) - **Contact sensors** (edge sensors) ### Wiring Instructions Monitored entrapment protection devices require **4 wires**: 1. From the device, connect **Relay Common → Board COMMON**. 2. Connect **Normally Closed (N.C.) relay contact → MON-OPEN or MON-CLOSE input**. 3. Use **MON +24VDC** and **COMMON** to power the device and enable monitoring. ### Important Notes ⚠ **10K Termination** – The **ALL-BLDC PRO** also supports 10K termination devices. *(See previous page for wiring details.)* - **Power Behavior** – The **MON +24VDC** terminal is **off when the gate is at rest**. - It is normal to see the **MON-OPEN** and **MON-CLOSE LEDs ON** when the gate is closed. - The same applies if the auto-close timer is **OFF** and the gate is resting in the open position. - If no devices are connected, both LEDs will remain ON. - **Manufacturer Guidance** – Always follow the device **manufacturer's wiring instructions**, using **N.C. wiring directions** unless otherwise specified. - **Expansion** – If more than one entrapment protection device is required for each direction, use **AUX INPUT 1** or **AUX INPUT 2** as monitored input expansion. *(See LCD Display → AUX input section for programming inputs as MON-OPEN or MON-CLOSE.)* > Figure: Wiring diagram for a “Closing direction device” and an “Opening direction device.” Each device terminal block is labeled “12-24 VDC NON-POLARITY” and “RELAY,” with terminals marked “N.C.,” “N.O.,” and “COM.” Colored wiring connects to the ALL-BLDC PRO control board terminals, including MON +24VDC, COMMON, MON_CLOSE, and MON_OPEN. > Figure: ALL-BLDC PRO control board photograph showing its display, buttons, status LEDs, terminal strips, relay terminals, LINE-IN, BATTERY, and FUSE. ### MON-CLOSE *(LED indicates obstruction or missing device)* - Used for the **monitored entrapment device in the close direction**. - When closing, the gate will: - **Reopen fully** if an obstruction is detected. - **Reset the auto-close timer**. - Has no effect during opening. - If no device is connected or a fault is detected (**MON_FAULT LED ON**), the operator will only run with a **constant pressure switch**. - Once the obstruction is cleared, normal operation resumes. ### MON-OPEN *(LED indicates obstruction or missing device)* - Used for the **monitored entrapment device in the open direction**. - When opening, the gate will: - **Reverse for 2 seconds** and stop if an obstruction is detected. - Has no effect during closing. - If a device is connected but a fault is detected (**MON_FAULT LED ON**), the operator will only run with a **constant pressure switch**. - Once the obstruction is cleared, normal operation resumes. ## Page 29 # ALTERNATE UL APPROVED MONITORED ENTRAPMENT PROTECTION DEVICE WIRING **Edge Sensors:** <u>Miller Edge Inc (FDDR2/8.E147902):</u> Models RB-G-K10, MGO20 <u>EMX Industries Inc (FDDR2/8.E315703):</u> Models WEL-200 <u>BBC Bircher (FDDR2/8/E526858):</u> Model XL-CP series – For use only with the Bircher XRF wireless transmission system only. **Transmission System:** <u>BBC Bircher (FDDR2/8/E526858):</u> Model XRF-R.2, XRF-TI. **Photoeyes:** <u>EMX Industries Inc (FDDR2/8.E315703):</u> Models IRB-RET2, IRB-MON2 <u>Miller Edge Inc (FDDR2/8.E147902):</u> Models TG-R, OG-T **Expansion Module:** <u>Miller Edge Inc (FDDR2/8.E147902):</u> Models MIM62Wireless Refer to the device manufacturer’s wiring instructions when installing. **MON-CLOSE** – Protects across the driveway during **closing.** **MON-OPEN** – Protects the rear slide during **opening.** | OMRON E3K-R10K4-NR | | | |---|---|---| | SWITCH | CONTACT | BOARD TERMINAL | | LIGHT ON | N.O.2 | MON_CLOSE OR MON_OPEN | | | C.2 | COMMON | | | 24 TO 240 VAC | COMMON | | | 24 TO 240 VAC | MON_12/24VDC | | EMX NIR-50-325 | | |---|---| | WIRE | BOARD TERMINAL | | BLACK | MON_CLOSE OR MON_OPEN | | WHITE | COMMON | | BLUE | COMMON | | BROWN | MON_12/24VDC | | EMX IRB-MON | | | |---|---|---| | SWITCH | CONTACT | BOARD TERMINAL | | SW1 - OFF | N.C. | MON_CLOSE OR MON_OPEN | | SW2 - OFF | COM | COMMON | | SW3 - ON | POWER/VRX | COMMON | | SW4 - OFF | POWER/VRX | MON_12/24VDC | | EMX IRB-325 | | |---|---| | CONTACT | BOARD TERMINAL | | N.C. | MON_CLOSE OR MON_OPEN | | COM | COMMON | | POWER | COMMON | | POWER | MON_12/24VDC | | EMX IRB-RET/2 | | | |---|---|---| | SWITCH | CONTACT | BOARD TERMINAL | | SW1 - OFF | N.C. | MON_CLOSE OR MON_OPEN | | SW2 - OFF | COM | COMMON | | SW3 - OFF | POWER/VRX | COMMON | | SW4 - ON | POWER/VRX | MON_12/24VDC | | EMX WEL-200 | | |---|---| | CONTACT | BOARD TERMINAL | | RELAY CLOSE (NC)<br>RELAY OPEN (NC) | MON_CLOSE<br>MON_OPEN | | RELAY CLOSE (COM)<br>RELAY OPEN (COM) | COMMON<br>COMMON | | POWER | COMMON | | POWER | MON_12/24VDC | | MILLER EDGE BRAND<br>6 WIRES FOR 1 EDGE - 8 WIRES FOR 2 EDGES | | | |---|---|---| | SWITCH | CONTACT | BOARD TERMINAL | | SW 1 - ON | N/C<br>N/C | MON_CLOSE<br>MON_OPEN | | SW 2 - ON | COM<br>COM | COMMON<br>COMMON | | SW 3 - ON | COM<br>A.TEST | COMMON<br>MON_12/24VDC | | SW 4 - ON | 12/24 (+)<br>AC/DC | 24-VDC<br>GROUND | ## Page 30 # LOOP LAYOUT - Below is a typical loop layout. When connecting to an All-O-Matic circuit board, use the following: - **SAFETY LOOP** - Normally Closed (N.C.) Contacts - **EXIT LOOP** - Normally Open (N.O.) Contacts (See next page for LPR-2 loop rack wiring) - Wires **MUST** be twisted from the exit point of the loop saw cut to the loop detector. - Twist loop wires 6 turns per foot, as shown below. Improper twisting of wires can cause loop issues. - When using an inside and outside safety loop, loops must be **WIRED IN SERIES.** > Figure: Loop-layout drawing labeled **OUTSIDE PROPERTY** above the gate track and **INSIDE PROPERTY** below. A horizontal **GATE TRACK** crosses between two vertical gate-post drawings. A gate and **GATE OPERATOR** are shown at left. Three rectangular loops are shown: two labeled **SAFETY LOOP** and one labeled **EXIT LOOP / WHEN USED**. The two safety loops are wired in series to the operator; the callout reads **WIRED IN SERIES**. Twisted lead wires are illustrated and labeled **TWISTED 6 TURNS PER FOOT**. A note states: **NOTE: IF WIRES ARE NOT TWISTED, LOOP WILL MALFUNCTION.** Dimensions: safety-loop width **8 FT**; each loop depth **4 FT**; spacing between upper safety loop, track, and lower safety loop is shown as **4 FT** intervals; lower safety loop to exit loop is **8 FT**; exit loop depth is **4 FT**. An enlarged dashed-circle inset depicts saw-cut/loop-wire placement with dimensions **1/4 IN** and **1 1/2 IN**. ## Page 31 # PLUG-IN DETECTOR INSTALLATION - The SL-90DC PRO, SL-100DC PRO and SL-150DC PRO models come equipped with the pre-wired LPR-2 loop rack for safety and exit plug in loop detectors, making installation quick and efficient. - Hardwired loop detectors with harnesses can also be installed. The circuit board has 12 VDC and 24 VDC terminals to power the detector of your choice. See “Accessory Connections” page for wiring instructions. - Wire one or more safety devices in series with the loop rack wires. To do this, remove the white wire (N.C) from the loop rack off of the SAFETY terminal on the circuit board and wire nut to the COM of the additional device. The N.C. contact of the additional device will now go on the SAFETY terminal of the board. - **IMPORTANT:** Use different frequencies for each loop detector to eliminate interference. | LOOP RACK | DC BOARD | WIRE COLOR | |---|---|---| | +V | +12VDC | RED | | -V | COMMON | BLACK | | EXIT LOOP | EXIT LOOP | GREEN | | PHAN | PHAN LOOP | BROWN | | SAFETY | SAFETY LOOP | WHITE | > Figure: Photograph of an ALL-O-MATIC INC. **LPR-2** loop rack with red enclosure, green terminal blocks, and three plug-in detector positions. Readable enclosure labels include **EXIT**, **EXIT/ENTER**, **PHANTOM**, **SAFETY/REVERSE**, **SAFE**, and **FAIL**. > Figure: Wiring diagram from the LPR-2 loop rack to three loop drawings labeled **Exit loop / WHEN USED**, **Inside Safety loop**, and **Outside Safety loop**. A callout identifies **Only for swing gates** near the exit-loop connection. The two safety loops are shown connected in series. > Figure: Photograph of three red plug-in loop detector modules installed in an LPR-2 rack. Readable label: **ALL-O-MATIC INC.** and **LPR-2**. > Figure: Circuit-board terminal illustration with wires from the loop rack. Terminal labels visible include **+12VDC**, **COMMON**, **EXIT LOOP**, **PHAN LOOP**, **SAFETY LOOP**, **FIRE ACCESS**, **MON-CLOSE**, **MON-OPEN**, **MON-FAULT**, and **OPEN**. Status labels include **P/S LINK**, **RADIO**, **EXIT LOOP**, **PHAN LOOP**, **SAFETY LOOP**, and **FIRE ACCESS**. Callout: “Remove Safety loop wire jumper when a SAFEFY LOOP detector is installed.” > Figure: Image of an All-O-Matic **PRIME-VD1 VEHICLE DETECTOR**. Its printed settings chart includes: > > | SETTINGS | SW1 | SW2 | > |---|---:|---:| > | SENSITIVITY | | | > | LOW | OFF | OFF | > | MEDIUM LOW | ON | OFF | > | MEDIUM HI | OFF | ON | > | HIGH | ON | ON | > | FREQUENCY | SW5 | SW6 | > | HIGH | OFF | OFF | > | MEDIUM HI | ON | OFF | > | MEDIUM LOW | OFF | ON | > | LOW | ON | ON | > > Additional readable labels: **INDICATORS: RED - DETECTOR; GREEN - PWR/LOOP FAIL**; **GREEN LED BLINKING INDICATE LOOP FAIL: 1 BLINK - OPEN LOOP; 2 BLINKS - LOOP SHORTED**; **OUTPUT FAIL-SECURE / FAIL-SAFE**; “PRESS RESET AFTER CHANGING SENSITIVITY AND FREQUENCY SETTINGS.” **IMPORTANT:** Dip switch **SW3** on PRIME-VD1 must be set when installing the detector in order for it to work properly. Use chart to set the output of the detector either **FAIL-SECURE** (N.O.) or **FAIL-SAFE** (N.C.). **OFF** will set the output as **FAIL-SECURE** and **ON** will set output as **FAIL-SAFE**. See chart below. | OUTPUT | SW3 | |---|---| | EXIT/PHANTOM | OFF | | SAFETY | ON | ## Page 32 # ACCESSORY WIRING ## Auxiliary Power & Inputs - **Accessory Power** – +12VDC (750 mA) and +24VDC (750 mA) available. Use a **separate power supply** if accessory draw exceeds these limits. - **Factory Jumpers** – Remove jumpers when wiring: - Safety loop: **COMMON ↔ SAFETY LOOP** - Stop button: **STOP ↔ COMMON** - **Aux Inputs (1 & 2)** – Programmable as **N.O., N.C., or 10K** for entrapment devices. See **LCD Display** section for setup. > Figure: Drawing of four access-control devices inside a dotted border: telephone entry/keypad, push-to-exit button, key switch, and card reader. Text: “TELEPHONE ENTRY, KEY SWITCH / PUSH BUTTON & CARD READER / OR ANY OPEN ACCESS DEVICE.” > Figure: Accessory wiring diagram centered on an **ALL-BLDC PRO** circuit board. Inputs and connected devices are shown with labeled wires: > > - **EXIT LOOP DETECTOR:** COMMON and **N.O.** > - **SAFETY (REVERSE) LOOP DETECTOR:** COMMON and **N.C.** > - **FIRE ACCESS:** **N.O.** and COMMON > > Board terminal labels include **RADIO**, **COMMON**, **RESET**, **ALARM**, **OPEN**, **STOP**, **CLOSE**, **+12VDC**, **EXIT LOOP**, **PHAN LOOP**, **SAFETY LOOP**, **FIRE ACCESS**, **MON +24VDC**, **MON_CLOSE**, **MON_OPEN**, **FP_DISABLE**, **+12VDC OUTPUT**, **+24VDC OUTPUT**, **AUX INPUT 1**, **AUX INPUT 2**, and COMMON. Board labels also include **MODE**, **OPENING**, **OPEN LIMIT**, **CLOSING**, **CLOSE LIMIT**, **AUX-IN 1**, **AUX-IN 2**, **POWER**, **LINE-IN**, **BATTERY**, and **FUSE->**. > > The lower diagram shows power wiring to a **SOLENOID LOCK**, **MAGNETIC LOCK**, and **24VDC SOLAR PANEL**, with plus and minus polarity markings and two devices labeled **POWER**. ## Lock Release Delay - The **ALL-BLDC PRO** includes a **0.5s built-in delay.** - Some locks may require a **longer delay** to release. - Adjust delay under **Auxiliary Relay & Leaf Delay settings.** - ⚠ Delay can be set on either **Primary** or **Secondary** operator. ## Page 33 # ACCESSORY WIRING (CONT.) ### Three-Button Station - The control board includes an **integrated 3-button station** and **RESET button** for limit and ERD adjustments. - An **external 3-button station** may also be installed. *(See wiring diagram below.)* - □ **Important:** Remove the **STOP jumper** when installing an external 3-button station. > Figure: Three-button station wiring diagram. A station contains buttons labeled **OPEN** (black), **STOP** (red), and **CLOSE** (black). The station COMMON wire connects to the control board terminal labeled **COMMON**. OPEN connects as **N.O.** to terminal **OPEN**; STOP connects as **N.C.** to terminal **STOP**; CLOSE connects as **N.O.** to terminal **CLOSE**. A black arrow labeled **STOP Wire Jumper Removal** points to the jumper at the board STOP connection. Text: “(Required if a STOP button or device is connected.)” Circuit board labeled **ALL-BLDC PRO**. Visible terminal labels include: 24VDC, 12 VDC, +12/24VDC, RADIO, COMMON, RESET, COMMON, OPEN, STOP, CLOSE, +12VDC, COMMON, EXIT LOOP, PHAN LOOP, SAFETY LOOP, FIRE ACCESS, COMMON, MON +24VDC, COMMON, MON_CLOSE, MON_OPEN. --- ### Magnetic & Solenoid Lock Installation **Power Requirement** – A **step-down transformer** with the correct voltage is required for the lock accessory. - Most operators include a **120VAC outlet** for the transformer. - ⚠ **SL-45DC PRO does not include this outlet.** ### Connections 1. Plug the **transformer** into the 120VAC outlet receptacle. 2. From the transformer's low-voltage side: - Connect one wire directly to the **lock device**. - Connect the second wire to the board's **Lock Relay COMMON terminal**. ### Lock Wiring - **Magnetic Lock →** Connect the second lock wire to the **MAGLOCK terminal** on the relay. - **Solenoid Lock →** Connect the second lock wire to the **SOLENOID terminal** on the relay. *(See wiring diagram for reference.)* > Figure: Lock wiring diagram at lower portion of ALL-BLDC PRO board. Board terminals are labeled **RELAY-1**, **N.O.**, **N.C.**, **COMMON**, **SOLENOID**, **MAGLOCK**, **COMMON**, **+24VDC**, **SOLAR**, **COMMON**. Red and black wiring runs from two devices labeled **POWER** to illustrated solenoid and magnetic-lock devices. Polarity symbols **+** and **−** appear at the power connections. Board labels include **BATTERY CHARGER**, **AC PWR_ON**, **BLINKING = BLOWN FUSE**, and **LINE-IN − +**. ## Page 34 # SOLAR PANEL CONNECTION ### Solar Panel Requirements - **Panel Size** – Minimum **24VDC, 40W** panel required. - **Capacity** – Charging circuit supports up to **80W**. - With **(2) 14Ah 12VDC batteries**, a receiver, and **(2) monitored entrapment devices**, operators can provide about **20 cycles/day**. ### Installation Notes - Always use the **SOLAR input** for solar panels. - The onboard regulator includes **MPPT technology** for higher efficiency. - For heavier use, upgrade to **larger batteries**. - If more than **80W solar power** is required, use an **external charge controller/regulator.** *(See next page for details.)* ### Additional Information For solar applications (panel sizing, battery capacity, etc.), contact **All-O-Matic.** > Figure: ALL-BLDC PRO circuit board connected to a solar-panel illustration by a black cable with red and black conductors. An arrow identifies **MPPT ON BOARD REGULATOR 90+% EFFICIENCY**. Another arrow identifies the terminal connection: **CONNECT 24V PANEL INTO SOLAR INPUT ON CIRCUIT BOARD.** A further arrow identifies **CONNECT BATTERY HARNESS TO BATTERY PLUG ON THE BOARD**. Board labels include **SOLAR**, **BATTERY**, **FUSE->**, **LINE-IN**, **BATTERY CHARGER**, **BLINKING = BLOWN FUSE**, and **AC PWR_ON**. ## Page 35 # EXTERNAL SOLAR SYSTEM INSTALLATION ### External Solar Package - Connect **batteries directly to the BATTERY input.** - Batteries must be **upgraded to match application requirements.** *(See wiring diagram below.)* ### Important Wiring Notes - If more than **two solar panels** are used, special wiring precautions are required to avoid battery or regulator damage: - **12VDC panels →** wire in **series** to make 24VDC. - **24VDC panels →** wire in **parallel**. ### Additional Information For details on solar panel sizing, battery capacity, and application planning, contact **All-O-Matic.** > Figure: External solar-system wiring diagram. A device labeled **CHARGE CONTROLLER** has terminal groups labeled **SOLAR**, **BATTERY**, and **LOAD**. Solar terminals are numbered **4** (+) and **3** (−); battery terminals are numbered **2** (+) and **1** (−); load terminals are numbered **6** (+) and **5** (−). Labels include **CHARGING**, **LOAD DISCONNECT**, **TEMP. SENSE**, **SEALED OR FLOODED SELECT**, and “Remove Jumper Wire for Flooded Battery.” Red and black wires connect the charge controller to a solar-panel illustration and two stacked battery illustrations. A battery harness plugs into the control board; callout reads **CONNECT BATTERY PLUG INTO BATTERY ON CIRCUIT BOARD**. Board visible labels include **SOLAR**, **BATTERY**, **LINE-IN**, **FUSE->**, and **ALL-BLDC PRO**. ## Page 36 # LED Indicator Reference > Figure: Semi-transparent ALL-BLDC PRO circuit-board image behind two bordered text columns. Visible board labels include ALL-BLDC PRO, P/S LINK, RADIO, EXIT LOOP, PHAN LOOP, SAFETY LOOP, FIRE ACCESS, MON-CLOSE, MON-OPEN, MON-FAULT, OPEN, STOP, CLOSE, ALARM, TIMER, AC PWR_ON, BATTERY LOW, LINE-IN, BATTERY, and FUSE->. ### Communication & Control - **P/S LINK** – ON when Primary/Secondary communication is active. - **RADIO** – ON when the RADIO input is activated (closed to COMMON). - **EXIT LOOP** – ON when the EXIT input is activated (closed to COMMON). - **PHANTOM LOOP** – ON when the PHANTOM LOOP input is activated (closed to COMMON). - **SAFETY LOOP** – ON when the SAFETY LOOP input is activated (open to COMMON). - **FIRE ACCESS** – ON when the FIRE ACCESS input is activated (closed to COMMON). ### Monitored Inputs - **MON-CLOSE** – ON when the MON-CLOSE input is activated (open to COMMON) or if no device is installed. - **MON-OPEN** – ON when the MON-OPEN input is activated (open to COMMON) or if no device is installed. - **MON-FAULT** – ON if a fault is detected on MON-OPEN or MON-CLOSE devices (device missing or malfunctioning). ### Manual Controls - **OPEN** – ON when OPEN input or push button is activated (closed to COMMON). Can be ON with other inputs. - **STOP** – ON when STOP input or push button is activated (open to COMMON). - **CLOSE** – ON when CLOSE input or push button is activated (closed to COMMON). ### Alarms & Timers - **ALARM** – Turns ON for 5 minutes when operator shuts down after hitting an Obstruction (ERD) twice before closing. - **TIMER** – Blinks every 0.5s while counting down for auto-close. - **MODE** – - 1 blink / 2s = motor sensor feedback problem. - 2 blinks / 2s = motor overload. - 3 blinks / 2s = gate jammed. ### Gate Position - **OPENING** – ON while gate is opening. - **OPEN-LIMIT** – ON when the open limit switch is activated. - **CLOSING** – ON while gate is closing. - **CLOSE-LIMIT** – ON when the close limit switch is activated. ### Auxiliary & Other Inputs - **AUX-IN 1** – ON when AUX INPUT 1 is activated (closed to COMMON). - **AUX-IN 2** – ON when AUX INPUT 2 is activated (closed to COMMON). - **FP-DISABLE** – ON when the foot pedal is pressed. ### Power Status - **AC/PWR ON** – ON when AC power is present. Blinks every 0.5s if the main board fuse is blown. - **LOW-BATTERY** – ON when batteries are low, off, or disconnected. ### Tips - When troubleshooting, **always note which LEDs are ON** – they indicate board activity and active inputs. - When calling **All-O-Matic Technical Support**, have the list of active LEDs ready. This will **speed up diagnosis** and help restore operation quickly. ## Page 37 # TECHNICAL TIPS | Operator Symptom | Solutions (diagnose) | |---|---| | Opening or closing LEDs are on, but gate doesn't move | If **AC PWR_LED** is blinking, replace the fuse at bottom right corner of the board. After replacing the fuse and before a signal is given, inspect the gate and make sure it's not bound up and that the limit switches are set correctly. If gate still doesn’t run, check motor harness and make sure it is plugged in correctly and no wires are loose. | | Radio receiver doesn’t work | Jumper at top left corner by factory is set on 12VDC. If the receiver requires 24VDC, move the jumper to 24VDC. | | AC PWR_ON LED is off | Make sure main high voltage power is connected and AC power switch is in the ON position. If that is fine, check 10Amp fuse in EMI board in the power box. If it's blown, check rectifier, it may also be damaged and need to be replaced along with the 10Amp fuse. | | Gate opens very slow | Check limit switch adjustment. Usually when gate opens very slow it is due to gate hitting the receiving post or positive stop before close limit switch activates. Check the variable speed setting to be sure it's set at 100%. Check that the AC power is turned ON and that the AC PWR_ON LED is lit. Also, make sure limit learning has been done. See below. | | Learning the limits for soft stop function. | Set the gate in closed position with the close limit activated. Press and release the RESET button on board. Run the gate a full cycle (full open and full close) without interruption. The first cycle will be slower while learning the distance between limits. It will run full speed once limits have been learned. | | Gate does not run and ALARM LED is ON | Gate is in Shut down mode due to obstruction detection. Press red RESET button outside control box next to radio connector. Run the gate and inspect gate is bound up or jammed. Test ERD sensitivity. See ERD adjustment page for details on the adjustment. | | Gate does not run and FP_DISABLE is ON | Check foot pedal and make sure it's up. Foot pedal has a kill switch and when it's down, it disables the operator. | | Gate does not run and STOP LED is ON | Check STOP input device and make sure it is not activated. Remember, this input is N.C. and LED will stay on if the wrong contact is used. | | Gate does not run and MODE LED blinks | See LED DIAGNOSTICS for details on the meaning of the blinks. | | Gate doesn't close | Check LEDs, any of the following input LEDs will prevent gate from closing. Check inputs for LEDs that are ON: RADIO, OPEN, STOP, EXIT LOOP, PHAN LOOP, SAFETY LOOP, FIRE ACCES, MON-CLOSE (check wiring and alignment), FP_DISABLE, (AUX INPUT 1 & 2, depending on programmed function). Also, check if AC PWR_ON LED is OFF(if it's OFF and dip-switch 4 or 7 are ON, gate will remain open). | | Gate doesn't open | Check LEDs, any of the following input LEDs will prevent gate from opening. Check inputs for LEDs that are ON: STOP, CLOSE, MON-OPEN, FP_DISABLE and AUX INPUT 1 or 2 (depending on programmed function). Also, check if AC PWR_ON LED is OFF (if it's OFF and dip-switch 4 is OFF, gate will remain closed if battery is low) | | Gate stops and reverses before reaching limits | Check ERD. If no obvious obstruction is present, it may need to be adjusted and increase the force for the direction it is stopping. See ERD adjustment page for details. | | Gate stops and reverses open | Check LEDs and see if any of them turn ON when gate reverses. It may be that the gate movement might be activating that device. See above the devices that prevents gate from closing. | ## Page 38 # AUX INPUT 1 & 2 PROGRAMMING AUX INPUT 1 & 2 can be programmed to do different functions. Below are the options **1 AUX INPUT 1** 1. **EMERGENCY OPEN** (factory default) Devices connected to the input in this function, will open the gate and will override MON-OPEN devices. Use N.O. contact. 2. **PARTIAL OPEN** (set partial open in %) Devices connected to this input in this function, will open the gate partially to set opening %. Use N.O. contact from device relay. 3. **OPEN-CMD** Devices connected to this input in this function, will open the gate. Use N.O. contact from device 4. **CLOSE-CMD** Devices connected to this input in this function, will close the gate. Use N.O. contact. 5. **MON-OPEN** In this function, this input is an expansion for open direction entrapment protection devices. N.C. or 10K termination can be used on device. **IMPORTANT:** If N.C. termination is used, must use MON +24VDC to power device. 6. **MON-CLOSE** In this function, this input is an expansion for close direction entrapment protection devices. N.C. or 10K termination can be used on device. **IMPORTANT:** If N.C. termination is used, must use MON +24VDC to power device. 7. **STOP-CMD** Devices connected to this input in this function, will stop the gate. Use N.C. contact. **2 AUX INPUT 2** 1. **EMERGENCY CLOSE** (factory default) Devices connected to the input in this function, will close the gate and will override MON-CLOSE devices. Use N.O. contact. 2. **PARTIAL OPEN** (set partial open in %) Devices connected to this input in this function, will open the gate partially to set opening %. Use N.O. contact from device relay. 3. **OPEN-CMD** Devices connected to this input in this function, will open the gate. Use N.O. contact from device 4. **CLOSE-CMD** Devices connected to this input in this function, will close the gate. Use N.O. contact. 5. **MON-OPEN** In this function, this input is an expansion for open direction entrapment protection devices. N.C. or 10K termination can be used on device. **IMPORTANT:** If N.C. termination is used, must use MON +24VDC to power device. 6. **MON-CLOSE** In this function, this input is an expansion for close direction entrapment protection devices. N.C. or 10K termination can be used on device. **IMPORTANT:** If N.C. termination is used, must use MON +24VDC to power device.. 7. **STOP-CMD** Devices connected to this input in this function, will stop the gate. Use N.O. contact. See next page on details on how to navigate through LCD display menu to program desired function on AUX INPUT 1 & 2. > Figure: Photograph/diagram of a red control board with terminal blocks. Readable terminal labels: “MON +24VDC,” “COMMON,” “MON_CLOSE,” “MON_OPEN,” “FP_DISABLE,” “COMMON,” “+12VDC OUTPUT,” “COMMON,” “+24VDC OUTPUT,” “COMMON,” “AUX INPUT 1,” “AUX INPUT 2,” and “COMMON.” Additional visible labels include “FP_DISABLE,” “N.O. RELAY-1,” “N.C.,” “COMMON,” “SOLENOID,” and “MAGLOCK.” Two callout boxes point with black lines to the AUX INPUT terminal connections. Upper callout: “Connect device relay contacts to these two terminals. Relay COMMON to board COMMON. RELAY N.O., N.C. or 10K to AUX INPUT 1. The relay contact depends on the function. See above for contact options.” Lower callout: “Connect device relay contacts to these two terminals. Relay COMMON to board COMMON. RELAY N.O., N.C. or 10K to AUX INPUT 2. The relay contact depends on the function. See above for contact options.” ## Page 39 # LCD SETTINGS AND DIAGNOSTICS **These instructions will take you through the ALL-BLDC PRO board LCD display menu.** Press OK a few times to wake the display until the options \<ENG> and \<ESP> appear. Select English with the left button or Spanish with the right button. After choosing a language, scroll to Settings or Diagnostics and press OK to enter. Use the up and down buttons to scroll, left and right to move the cursor, and press OK to save or select items. ## SETTINGS ### 1. TIME/DATE #### 1.1 TIME (XX:XX AM/PM) 1. Press **OK** when the cursor is on **TIME**. 2. Use **Left/Right** to move between hour, minutes, and AM/PM. 3. Use **Up/Down** to adjust values. 4. Press **OK** to save. #### 1.2 DATE (MM/DD/YYYY) 1. Press **OK** when the cursor is on **DATE**. 2. Use **Left/Right** to move between month, day, and year. 3. Use **Up/Down** to adjust values. 4. Press **OK** to save. ### 2. SPEED #### 2.1 MAX SPEED (100%) Adjusts the motor's maximum running speed. #### 2.2 ACCELERATION (FST) Adjusts how quickly the motor ramps up to speed. #### 2.3 SLOW DOWN (2 FEET) Adjusts the distance for when the motor begins slowing down as it approaches the limit switch. ### 3. POWER #### 3.1 CURR. SENSE (PRGV) Adjusts how responsive the ERD is. Options are **Progressive** and **Threshold**, with **Threshold** being the most sensitive. #### 3.2 ERD - **OPEN ERD** – Adjusts opening ERD force (also accessible with the quick-access **OPEN ERD** button). - **CLOSE ERD** – Adjusts closing ERD force (also accessible with the quick-access **CLOSE ERD** button). ### 4. 7-DAY TIMER #### 4.1 EVENTS (1–10) Each event allows you to program an **Action** with an **Activate Time**, a **Deactivate Time**, and specific **Days of the Week**. Up to 10 events can be programmed. **Technician's Note:** Run a full gate cycle before programming events to ensure proper operation. #### 4.2 EVENT ACTION OPTIONS *(an \* will be displayed to the right of selected action.)* - **OPEN** – Opens gate and holds it open. - **CLOSE** – Closes gate and holds it close. - **AUXILIARY RELAY** – Activates the auxiliary relay. #### 4.3 PROGRAMMING AN EVENT (Step-by-Step) i. **Select an Event (1–10):** Scroll to the desired event number and press **OK**. ii. **Choose Action:** Use **Up/Down** to select **OPEN**, **CLOSE**, or **AUXILIARY RELAY**, then press **OK**. iii. **Set Activate Time:** 1. Cursor appears on the hour field. 2. Use **Left/Right** to move between hours, minutes, and AM/PM. 3. Use **Up/Down** to adjust values. 4. Press **OK** to confirm. iv. **Set Deactivate Time:** 1. Follow the same process as above for the deactivate time. 2. Press **OK** to confirm. v. **Enable Days:** 1. Scroll through days of the week (Mon → Sun). 2. Toggle each day **ON** or **OFF** using **Up/Down**. 3. After setting all days to the desired state, press **OK** to confirm. vi. **Save Event:** Once all steps are completed, the event is saved and ready to run. ### 5. LEAF DELAY #### 5.1 DELAY TYPE Select whether the delay applies to **OPEN** or **CLOSE**. This function is mainly used for swing gates that overlap. #### 5.2 DELAY TIME (00.0 SEC) Set the delay duration in seconds. Use **Up/Down** to adjust the value and press **OK** to confirm. ### 6. PRE-WARN *(Uses the built-in audible alarm to warn before the gate starts moving.)* #### 6.1 ALARM ON/OFF Enable or disable the alarm. Set to **ON** to activate, or **OFF** to deactivate. #### 6.2 DELAY TIME (00.0 SEC) Adjust the number of seconds the alarm sounds before gate movement. Range: **0–12 seconds**. Use **Up/Down** to adjust the value, then press **OK** to confirm. ## Page 40 # LCD SETTINGS AND DIAGNOSTICS (CONT.) ### 7. AUXILIARY RELAY *(Options for relay activation.)* #### 7.1 RELAY MODES Select one of the following functions for the auxiliary relay: *(an \* will be displayed to the right of selected mode.)* 1. **OFF (INACTIVE)\*** – Default setting; relay is disabled. 2. **PRE-WARN SIGNAL** – Activates before gate movement; functions similar to the Pre-Warn Alarm. 3. **MOVING SIGNAL** – Activates while the gate is moving. 4. **OPENED SIGNAL** – Activates when the gate is fully open. 5. **CLOSED SIGNAL** – Activates when the gate is fully closed. 6. **PULSE ON OPEN** – Sends a 1-second pulse when the open limit is reached. ### 8. AUXILIARY INPUT *(Input 1 defaults to EMERGENCY OPEN, and Input 2 defaults to EMERGENCY CLOSE.) See auxiliary input page for more details.* #### 8.1 INPUT MODES (1–2) Each auxiliary input can be configured with one of the following functions: *(an \* will be displayed to the right of selected mode.)* 1. **EMERGENCY OPEN / CLOSE\*** – Overrides monitored inputs and forces the gate to fully open or close. 2. **PARTIAL OPEN** – Opens the gate partially, based on the programmed percentage setting. 3. **OPEN_CMD** – Functions the same as a standard open input. 4. **CLOSE_CMD** – Functions the same as a standard close input. 5. **MON-OPEN** – Expansion of the monitored open input. 6. **MON-CLOSE** – Expansion of the monitored close input. 7. **STOP_CMD** – Functions the same as the STOP input. ### 9. RADIO LATCH *(Used to temporarily hold the gate open using the radio receiver.)* #### 9.1 ACTIVATION 1. In the **SETTINGS** list, scroll to **RADIO LATCH** and press **OK**. 2. Use **Up** to turn the function **ON**, then press **OK** to confirm. #### 9.2 FUNCTION 1. When **ON**, activating the radio receiver will open the gate. 2. Once the gate is fully open, press the remote button again to enable **Hold Open** mode. 3. To release **Hold Open**, press the remote button once more. The gate will then time out and close. 4. While active, the display will show: **RADIO LATCH MODE ACTIVE**. This indicates the gate is held open by this function. To allow closing, press the remote button once; the gate will time out and close. ### 10. MON-INPUT *(Used to set the 10K device as either Safety Edge or Photo Eye.)* #### 10.1 SETTINGS 1. Scroll to **MON-INPUT** in the menu and press **OK** twice. 2. Select **10K EDGE** or **10K PHOTO EYE**, then press **OK** to confirm. #### 10.2 FUNCTION - **10K EDGE** – Assigns the input to a safety edge device. - **10K PHOTO EYE** – Assigns the input to a photo eye sensor, preventing false alarms or allowing slowdowns when detecting obstructions. ### 11. SERVICE CYCLE *(Provides a planned service reminder based on run cycles.)* #### 11.1 SETTINGS 1. Scroll to **SERVICE CYCLE** in the menu and press **OK**. 2. Program the number of cycles the gate should run before the next preventive maintenance service call. 3. Press **OK** to confirm. #### 11.2 FUNCTION - The control board begins counting down from the programmed number. - When the count reaches zero, the board will beep to alert the end user that it's time to schedule service. - The cycle count can be reset by a technician in the **Diagnostics → Cycle Count** menu. #### 11.3 COUNT (00000) 1. Use **Left/Right** to move the cursor between tens, hundreds, thousands, and ten-thousands positions. 2. Use **Up/Down** to adjust the value. 3. Press **OK** to confirm. ### 12. AUTO CLOSE TIMER *(See timer page for more details on this)* #### 12.1 SETTINGS 1. Scroll to **AUTO CLOSE TIMER** in the menu and press **OK**, or press the quick-access **TIMER** button. 2. Use **Up/Down** to set the delay (0–120 seconds). 3. Press **OK** to confirm. ## Page 41 # LCD SETTINGS AND DIAGNOSTICS (CONT.) **13. SETTINGS CHG LOG** *(Keeps a record of the last three times settings were changed.)* - **13.1 ENTRIES** - **01-03. SETTINGS CHG – XX/XX/XX 00:00 AM** Shows the saved date and time of the changes **14. FIRMWARE UPDATE** *(Allows firmware to be upgraded in the field.)* - **14.1 UPDATE PROCESS** 1. Obtain the firmware **BIN** file from AOM (provided via email). 2. Copy the file to a thumb drive formatted to **FAT, FAT16, or FAT32**. 3. Plug the thumb drive into the board's **USB port**. 4. Follow on-screen instructions to complete the update. **15. WIRELESS SETUP** *(For wireless PRIMARY/SECONDARY setup. Assign unique channels if other systems are nearby. 8 channels available.)* - **15.1 WIRELESS CHANNEL** 1. Ensure both operators in a pair are set to the **same channel**. 2. If other systems are nearby, select a different channel to avoid conflict. **16. SET TO DEFAULT** *(Restore individual settings, or all settings, to factory defaults.)* - **16.1 OPTIONS** 1. **DEFAULT ALL** – Restores all settings. 2. **DEFAULT SPEED** – Restores speed settings. 3. **DEFAULT POWER** – Restores power settings. 4. **DEFAULT 7/D TMR** – Restores 7-Day Timer settings. 5. **DEFAULT LEAF DLY** – Restores leaf delay settings. 6. **DEFAULT PRE ALRM** – Restores pre-warn alarm settings. 7. **DEFAULT AUX RLY** – Restores auxiliary relay settings. 8. **DEFAULT AUX INS** – Restores auxiliary input settings. 9. **DEFAULT RADIO LA** – Restores radio latch settings. 10. **DEFAULT MON 10K** – Restores mon-input settings. 11. **DEFAULT SVC CYC** – Restores service cycle settings. 12. **DEFAULT AUTO CLS** – Restores auto close timer settings. 13. **DEFAULT WIRELESS** – Restores wireless setup settings. # DIAGNOSTICS **1. GATE STATUS** Displays whether the gate is **CLOSED, OPENED, or STOPPED**. **2. COMMUNICATION** *(Displays the current communication mode.)* 1. **Wireless** 2. **Wired** **3. 7/D TMR STATUS** Displays if the gate is being held open or if the relay is active by the 7-Day Timer. **4. METER** *(Provides real-time voltage readings.)* 1. **BATT VOLTAGE** – Displays battery voltage. 2. **LINE IN VOLTAGE** – Displays line input voltage. **5. MOTOR** *(Displays motor speed and gate travel as a percentage.)* - **5.1 MOTOR SPEED** Shows the current operating speed of the motor. - **5.2 TRAVEL** Displays the percentage of gate travel completed. **6. LAST EVENT** *(Displays the most recent event recorded by the system.)* - **6.1 EVENT NAME** Example: **50. (LAST LOGGED EVENT NAME)** - **6.2 EVENT DATE & TIME** Example: **XX/XX/XX 00:00 PM** **8. EVENT LOG** *(Stores up to 50 special events.)* - **8.1 LOGGED EVENTS** Displays entries **1–50** in the event log. **9. CYCLE COUNT** *(Displays the unit's cycle counts, including service cycles if programmed.)* - **9.1 LIFE CYCLES** Total number of cycles since installation. - **9.2 MONTH CYCLES** Total cycles for the current month. - **9.3 DAY CYCLES** Total cycles for the current day. - **9.4 SERVICE CYCLES** Displays the programmed service cycle count. If the count reaches zero, the option to reset will appear. ## Page 42 # LCD SETTINGS AND DIAGNOSTICS (CONT.) **10. EXPORT TO USB** *(Allows settings and diagnostic data to be exported for review on a smartphone or PC. The thumb drive must be formatted to FAT, FAT16, or FAT32.)* - **10.1 EXPORT PROCESS** Insert a formatted thumb drive into the USB port to export data and follow the prompt. # EVENT LOG – POSSIBLE FAULTS AND DEFINITIONS *(The event log records up to 50 events, including system faults. Review these entries during diagnostics to identify and correct issues.)* **General Notes:** 1. Inputs that remain active for more than 5 minutes should be investigated. This may be intentional, but it could also indicate a phantom issue that intermittently holds the gate open or closed. 2. Logged inputs showing ON/OFF changes help diagnose the cause of gate malfunctions. 3. **P/S LINK OFF** and **P/S LINK ON** events indicate intermittent communication issues. - For hard-wired systems, check communication cable connections. - For wireless systems, check for possible sources of interference in the environment. # FAULT DEFINITIONS - **EXIT IN >5m** – Exit loop input active for more than 5 minutes. - **SAFE IN >5m** – Safety loop input active for more than 5 minutes. - **P/S LINK OFF** – Communication between Primary/Secondary operators lost. - **P/S LINK ON** – Communication between Primary/Secondary operators established. - **AC PWR OFF** – AC power lost. - **AC PWR ON** – AC power detected. - **BATTERY OFF** – Battery power lost. - **BATTERY ON** – Battery voltage detected. - **FUSE BLOWN** – Motor fuse blown. Replace fuse on main board. - **STOP CMD ON** – Stop command input activated, gate stopped. Check FP_DISABLE input. - **STOP CMD OFF** – Stop command input deactivated. - **RADIO IN >5m** – Radio input active for more than 5 minutes. - **EDGE IN ON** – Edge 10K input triggered. - **CLOSE IN >5m** – Close input active for more than 5 minutes. - **CLOSE ERD** – Close ERD tripped. Inspect gate and adjust ERD if necessary. - **OPEN ERD** – Open ERD tripped. Inspect gate and adjust ERD if necessary. - **PHANTOM >5m** – Phantom loop input active for more than 5 minutes. - **AC VOLT LOW** – AC voltage drop detected. Inspect main power connections. - **AC VOLT HIGH** – High AC voltage detected. Check power supply. - **MOTOR OL** – Motor overload. Check gate hardware and operator capacity. - **EEPROM ERROR** – Processor error. Replace board. - **MON-OPEN FLT** – Fault on monitored open input. Check entrapment device alignment/function. - **MON-CLOSE FLT** – Fault on monitored close input. Check entrapment device alignment/function. - **FIRE IN >5m** – Fire access input active for more than 5 minutes. - **OPEN IN >5m** – Open input active for more than 5 minutes. - **AUX1 OPEN >5m** – Aux1 Open input active for more than 5 minutes. - **AUX2 OPEN >5m** – Aux2 Open input active for more than 5 minutes. - **AUX1 CLOS >5m** – Aux1 Close input active for more than 5 minutes. - **AUX2 CLOS >5m** – Aux2 Close input active for more than 5 minutes. - **AUX1 PARTIAL OPEN >5m** – Aux1 Partial Open input active for more than 5 minutes. - **AUX2 PARTIAL OPEN >5m** – Aux2 Partial Open input active for more than 5 minutes. - **AUX1 FORCE OPEN >5m** – Aux1 Emergency Open input active for more than 5 minutes. - **AUX2 FORCE CLOSE >5m** – Aux2 Emergency Close input active for more than 5 minutes. - **AUX1 STOP ON** – Aux1 STOP input activated, gate stopped. - **AUX1 STOP OFF** – Aux1 STOP input deactivated. - **AUX2 STOP ON** – Aux2 STOP input activated, gate stopped. - **AUX2 STOP OFF** – Aux2 STOP input deactivated. - **MOTOR SF** – Motor sensor fault. Check motor harness connections. - **STOP-IN ON** – STOP input activated. - **STOP-IN OFF** – STOP input deactivated. ## Page 43 # EMERGENCY RELEASE FOR SL-45DC PRO **Manual Operation – SL-45DC PRO** 1. Remove the **operator cover**. 2. Turn both **AC** and **DC** switches **OFF**. 3. Push the **gate open** manually. > Figure: Illustration of a person manually pushing a sliding gate open. A gate operator at the right side is shown with its cover removed, exposing a red control board. The gate is supported by a post at right and includes two black vertical components near the post. No readable dimensions, torque specifications, wire specifications, arrows, or step labels are visible. ## Page 44 # EMERGENCY RELEASE FOR # SL-90DC PRO, SL-100DC PRO, AND SL-150DC PRO **Manual Operation – SL-90DC PRO, SL-100DC PRO, SL-150DC PRO** 1. Step on the **foot pedal** and move it to the side to latch in the **down position**. 2. Push the **gate open** manually. **Note:** These operators include a **DISABLE switch** on the foot pedal. When the pedal is down, the operator will not run—even if power is ON. The **FP-DISABLE LED** will illuminate when the foot pedal is pressed. > Figure: Illustration of a person stepping on a foot pedal at the base of a sliding gate operator while preparing to manually push the gate open. The operator cover is shown translucent/open, revealing internal components and labels including “EXIT,” “10K,” “SAFETY,” and “LIMIT SWITCHES.” The foot pedal is at the bottom of the operator. No readable dimensions, torque specifications, wire specifications, or arrows are visible. ## Page 45 [illegible] ## Page 46 [illegible] ## Page 47 [illegible] ## Page 48 [illegible] ## Page 49 > Figure: Cover-style graphic with a red geometric banner across the top; pale gray hexagonal outlines in the background; large ALL-O-MATIC logo in red letters over a blue oval. Bottom-right UL certification mark reads: “UL CERTIFIED”; “SAFETY US CA”; “SPILLER ELECTRICAL”; “E543801”, alongside a QR code.