LiftMaster®
# WIRING DIAGRAM
## Model RSL12UL
> Figure: LiftMaster RSL12UL wiring diagram. Main components shown include the Control Board, optional Expansion Board, plug-in transformer, plug-in loop detector, wireless edge kit (Model LMWKEVIT), auxiliary relays, outlet housing, optional heater, incoming power, control board wiring, solar option with 33AH battery, battery, reset switch, product ID, alarm, APS encoder, and motor. Dashed arrows identify wiring paths between boards and terminal groups.
| ⚠ WARNING |
|---|
| To reduce the risk of INJURY or DEATH: |
| • DISCONNECT power and battery BEFORE installing or servicing operator. |
| • Replace ONLY with fuse of same type and rating. |
| • To be compliant with UL325 and industry safety guidelines, qualified monitored external entrapment protection devices such as photoelectric sensors or edge sensors are required to be installed with this operator at each entrapment zone. ONLY LiftMaster approved entrapment protection devices (refer to the accessory page of manual). |
| • See owner's / installer operating maintenance and required safety testing. |
### Diagnostic Codes
**TO VIEW THE CODES:**
Press and hold STOP...
…then press and hold CLOSE...
…then press and hold OPEN until “Er” shows.
The operator will show the code sequence number followed by the code number:
**First code shown is the most recent code** (example: “01”). The display will show two “01” and going up to code “20”.
**TO SCROLL THE SAVED CODES:**
Press the OPEN button to cycle to the most recent code (“01”). Press the CLOSE button to cycle to the oldest code (up to “20”).
### Code Color Key
| Color | Meaning |
|---|---|
| Yellow | LiftMaster System |
| Orange | Installed System |
| Green | Informational |
| Dark red | External Entrapment Protection |
| Black | Inherent Entrapment Protection |
| CODE | MEANING | SOLUTION |
|---:|---|---|
| 31 | Main control board has experienced an internal failure. | Disconnect all power, wait 15 seconds, then reconnect power (board). If issue continues, replace main control board. |
| 32 | Linear Drive Disengaged (Arm 1) | Disengage or re-engage arm. Check wiring and connections. |
| 33 | Linear Drive Disengaged (Arm 2) | Disengage or re-engage arm. Check wiring and connections. |
| 34 | Absolute Position Encoder Error, not getting position information from encoder | Check the operator cable connections, then reprogram the limits. |
| 35 | Max-Run-Time Error | Checks for an obstruction, then reprogram the limits. |
| 36 | Product ID Error | Was the control board just replaced? If so, erase limits, enter limit setup mode and set limits. If not, disconnect all power, wait 15 seconds, then reconnect power before changing product ID harness. |
| 37 | Product ID Failure | Unplug product ID harness then plug back in. Disconnect all power, wait 15 seconds, then reconnect power before replacing product ID harness. |
| 38 | Hard Stop Limit (Arm 1) | Limit may be set too tightly against a hard-stop. Re-adjust limit. Operator may be at end of travel (re-adjust limit). |
| 39 | Hard Stop Limit (Arm 2) | [illegible] |
| 40 | Battery overvoltage | Make sure there is NOT a 24V battery on a 12V system. |
| 41 | Battery overcurrent | Possible short of the battery charge harness. Check harness. Make sure you do not have a 12V battery on a 24V system. |
| 42 | No battery at boot up | Check battery connections and installation. Replace battery if defective. Make sure there is less than 20V on a 24V system or less than 10V on a 12V system. Make sure there is NOT a single 12V battery on a 24V system. |
| 43 | Exit Loop Error | Failure or missing loop (SHORT or OPEN). |
| 44 | Shadow Loop Error | LiftMaster Plug-In Loop Detector only. Check loop wiring through both connection. May be a short in the loop, or an open connection in the loop. |
| 45 | Interrupt Loop Error | [illegible] |
| 46 | Wireless edge battery low | Replace batteries in wireless edge. |
| 50 | Run-Distance Error | Gate distance detected. Make sure the gate is installed on a level surface and not on an excessive grade. |
| 51 | Pass-point not detected (Arm 1) | Check yellow pass-point wiring. If limits are not accurate, reprogram. |
| 52 | Pass-point not detected (Arm 2) | [illegible] |
| 53 | Brownout occurred | AC/DC board supply dipped below allowable level. Review power supply and wiring. If rebooting, ensure enough time for discharge of power to force a fresh boot. |
| 54 | Wireless Second Operator Communication Error | Check the second operator for power. If OFF, restore power and try to run the system. If powered, deactivate the wireless feature and then reprogram the second operator. |
| 60 | Minimum number of monitored entrapment protection devices not installed. | Review monitored entrapment protection device connections. Slide gate operators require a minimum of two external safety devices; one in the close and one in the open direction. |
| 61 | CLOSE EYE/INTERRUPT held more than 3 minutes | Check wired input on main control board for alignment or obstruction. |
| 62 | CLOSE EDGE held more than 3 minutes | [illegible] |
| 63 | OPEN EYE/EDGE/BORDER held more than 3 minutes | [illegible] |
| 64 | CLOSE EYE/INTERRUPT held more than 3 minutes | Check wired input on expansion board; check for alignment or obstruction. |
| 65 | CLOSE EDGE held more than 3 minutes | [illegible] |
| 66 | OPEN EYE/EDGE held more than 3 minutes | [illegible] |
| 67 | Wireless edge triggered more than 3 minutes | Check wired input for wiring issue or obstruction. |
| 68 | Wireless edge loss of monitoring | Check wireless edge inputs. |
| 69 | Wireless edge triggered | If an obstruction occurred, no action required. If an obstruction did NOT occur, check inputs and wiring. |
| 70–75 | CLOSE EYE/INTERRUPT / OPEN EYE/EDGE triggered, causing reversal or preventing opening/closing | If an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, wiring, and main control board. |
| 80 | Close input (EYE/EDGE) communication fault from other operator | Check inputs and communication method between operators; either wired bus or radio. Ensure operator is powered. |
| 81 | Open input (EYE/EDGE) communication fault from other operator | [illegible] |
| 82 | Close input (EYE/EDGE) communication fault (expansion board) | Check the connections between the main board and the expansion board. |
| 83 | Open input (EYE/EDGE) communication fault (expansion board) | [illegible] |
| 84 | Non-monitored device detected on the wireless safety system | Non-monitored contact closure devices are not supported. Make sure connections are monitored. Check edges for proper orientation and resistive end cap connection. |
| 91 | Force Reversal (Operator 1) | Check for mechanical or environmental obstruction, check that the mechanical limit switch is engaged and free to move. See section on Limit and Force Adjustment. |
| 92 | Force Reversal (Operator 2) | [illegible] |
| 93 | RPM / STALL Reversal (Operator 1) | Check for obstruction. If no obstruction, check the operator wiring and that the mechanical assembly is engaged and free to move. Replace RPM assembly. |
| 94 | RPM / STALL Reversal (Operator 2) | [illegible] |
| 99 | Normal Operation | No action required. |
> Figure: Control Board. Labels include “COAXIAL CABLE,” “ANTENNA,” “Control Board,” “SET OPEN,” “SET CLOSE,” “LEARN,” “TEST BUTTONS,” “DIAGNOSTICS,” “STATUS,” “BATT FUSE 30A,” “BATT,” “DC POWER,” “MOTOR,” “SECURE / MANUAL,” “LIMITS,” “ENCODER,” and “ALARM.” A plug-in transformer is wired to the board.
> Figure: Terminal wiring groups at right of control board. Groups are labelled CONTROLS, LOOPS, ENTRAPMENT PROTECTION, DUAL GATES, LOCKS, and ACCESSORY POWER. Controls connect to Control Station, Fire Department, and Access Control Device. Loops connect to Exit Loop, Shadow Loop, and Interrupt Loop. Entrapment protection wiring connects photoelectric sensors and edge sensors for close cycle or open cycle. Dual-gate wiring shows “Primary/Secondary link to other gate operator” and “Shielded Twisted Pair Cable Ground the shield of each cable to the chassis ground of each operator.”
> Figure: Control terminals show OPEN, CLOSE, STOP, COMMON, FIRE DEPT, and EXIT. A “Jumper” is shown. Control station contacts include N.C. wiring.
> Figure: Loop terminals labelled EXIT, SHADOW, CLOSE EYES/INTERRUPT, and CLOSE. Loop drawings are labelled Interrupt Loop, Shadow Loop, and Exit Loop.
> Figure: Lock wiring. “Maglock (Optional) Not provided” and “Solenoid Lock (Optional) Not provided” are shown as alternate connections. Accessory-power terminals show “12 Vdc switched” and “12 Vdc always on.”
> Figure: Expansion Board (Optional Accessory), shown below the control board. Connected components include Plug-In Loop Detector, Wireless Edge Kit Model LMWKEVIT, loop inputs, entrapment-protection terminals, controls, and auxiliary relays.
> Figure: Auxiliary relays module with AUX RELAY 1 and AUX RELAY 2, relay contact terminals labelled NO COM NC, and output wiring. Adjacent “SWITCH SETTINGS” table configures Relay 1 and Relay 2 using switches 1, 2, and 3. Entries include: Relay always off; Energizes at open limit; Energizes when not at close limit; Energizes when motor is on; Energizes 3 seconds prior and during gate motion; Energizes with AC or solar power; Energizes when gate is tampered with; LEDs will blink cycle count / Not used.
> Figure: Solar (Optional) with 33AH battery. Labels: “Solar Panels (Optional) 10 W minimum – 30 W maximum wired in parallel,” “J15 Plug on 33AH Battery Harness (K94-37236),” “Diode,” “Black,” “Red,” “33AH Battery,” and two 10W 12V solar panels. Dashed red and black wiring identifies solar/battery connections.
> Figure: Outlet Housing and incoming power. Drawing shows back of outlet housing with two “Outlet” receptacles. Optional heater is connected to incoming power. Incoming power conductors are labelled HOT, NEUTRAL, and GROUND; wiring labels include Red, Black, White, and Earth Ground Rod.
> Figure: Bottom control-board wiring diagram. J15 Plug connects to a 12V 7AH Battery, optional solar panels, and diode. Product ID, reset switch, alarm, APS encoder, and motor are wired to the control board. Reset switch labels: “Run” and “Stop/Reset.” Alarm leads are Red and Black.
LiftMaster.com
© 2018, LiftMaster
All Rights Reserved
01-39104-4
## Page 2
LiftMaster®
# SCHÉMA DE CÂBLAGE
## Modèle RSL12UL
| ⚠ AVERTISSEMENT |
|---|
| Pour réduire le risque de BLESSURES GRAVES, voire MORTELLES : |
| • DÉBRANCHER l’alimentation (électrique ou à pile) AVANT de procéder à l’installation de l’actionneur ou à une intervention d’entretien sur celui-ci. |
| • Remplacer UNIQUEMENT par un fusible du même type et d’intensité nominale. |
| • Pour être conforme à la norme UL 325 et aux règles de sécurité industrielles, des dispositifs externes surveillés de protection contre le piégeage comme des capteurs photoélectriques ou des bordures de détection doivent être installés avec cet actionneur à chaque zone de piégeage. UNIQUEMENT les dispositifs de protection contre le piégeage LiftMaster approuvés (consulter la page des accessoires). |
| • Avant de consulter le manuel pour les instructions d’entretien et d’essai de sécurité. |
### Code d’anomalie
**POUR VOIR LES CODES :**
Enfoncer et tenir ensuite le bouton STOP...
…enfoncer et tenir le bouton « CLOSE »...
…puis enfoncer sans le relâcher le bouton OPEN jusqu’à la mention « Er ».
L’actionneur montrera le numéro de séquence du code suivi du numéro du code.
**POUR DÉFILER JUSQU’AUX CODES ENREGISTRÉS :**
Appuyer sur le bouton d’ouverture (OPEN) pour passer au code le plus récent (« 01 »). Appuyer sur le bouton de fermeture (CLOSE) pour passer au code le plus ancien (jusqu’à « 20 »).
### LÉGENDE DES COULEURS DE CODE
| Couleur | Signification |
|---|---|
| Jaune | Système LiftMaster |
| Orange | Système installé |
| Vert | Informatif |
| Rouge foncé | Protection externe contre le piégeage |
| Noir | Protection inhérente contre le piégeage |
> Figure: French-language version of the RSL12UL wiring diagram. Major components and wire paths match Page 1, with French labels.
> Figure: Carte logique with “CÂBLE COAXIAL,” “ANTENNE,” “Carte logique,” and “TRANSFORMATEUR ENFICHABLE.” Board labels include BATT FUSE 30A, BATT, DC POWER, MOTOR, SECURE / MANUAL, LIMITS, ENCODER, and ALARM.
> Figure: French terminal groups: COMMANDES, BOUCLES, PROTECTION CONTRE LE PIÉGEAGE, BARRIÈRES DEUX VANTAUX, SERRURES, and TROUSSE D’ACCESSOIRES. Connected devices include Poste de commande, Service d’incendie, Dispositif de contrôle d’accès, Boucle d’interruption, Boucle d’ombre, Boucle de sortie, Capteurs photoélectriques, Bordure de détection, Serrure électromagnétique, and Serrure à solénoïde.
> Figure: Entrapment-protection diagram showing photoelectric sensors “pour cycle de fermeture,” photoelectric sensors “pour cycle d’ouverture,” and edge sensors/border detection “pour cycle de fermeture ou cycle d’ouverture.” Alternate arrangements are marked “OU.”
> Figure: Dual gate connection labelled “Liaison primaire / secondaire à l’autre actionneur de barrière.” Shielded twisted-pair cable instruction: “Câble à paire torsadée blindé (liaison primaire / secondaire à l’autre actionneur de barrière à la borne de blindage du câble à la masse du châssis de chaque actionneur.”
> Figure: Carte d’extension (Accessoire en option), BOUCLE DE DÉTECTION ENFICHABLE, TROUSSE BORDURE SANS FIL Model LMWKEVIT, BOUCLES, and RELAIS AUXILIAIRES.
> Figure: Relay switch settings table headed “RÉGLAGES DU COMMUTATEUR,” “RELAIS 1,” and “RELAIS 2.” Switches 1, 2, and 3 are shown with combinations of ARRÊT/MARCHE. Functions include relays always off, activation at opening limit, activation when not at closing limit, activation while motor is running, activation before/during motion, activation with AC or solar power, activation if barrier is tampered with, and LED cycle count / not used.
> Figure: “Solaire (en option) avec batterie 33AH.” Labels include “Panneaux solaires (en option) 10 W minimum – 30 W maximum câblés en parallèle,” “Fiche J15 sur faisceau de batterie 33AH (K94-37236),” “Diode,” “Noir,” “Rouge,” “Batterie 33AH,” and 10W 12V panels.
> Figure: “BOÎTIER DE PRISE DE COURANT” and “Alimentation d’entrée.” Back of outlet housing has two receptacles labelled “Prise.” Optional heater is labelled “CHAUFFAGE (en option).” Incoming conductors include CHARGÉ, NEUTRE, TERRE, Rouge, Noir, Blanc, and “Tige de mise à la terre.”
> Figure: Bottom French control-board wiring. Components are labelled “ID DE PRODUIT,” “COMMUTATEUR DE RÉINITIALISATION,” “ALARME,” “ENCODEUR DE SYSTÈME DE POSITIONNEMENT ABSOLU,” and “Moteur.” Reset-switch positions are “Exécuter” and “Arrêter/réinitialiser.” Battery is labelled “Batterie 12V 7AH.”
LiftMaster.com
© 2018, LiftMaster
Tous droits réservés
01-39104-4