Skip to main content
## Page 1 > Figure: Isometric assembly drawing of the SL-90DC operator, shown with exterior plastic cover and internal frame/components. The cover bears the “ALL-O-MATIC” logo. No dimensions, torque specifications, wire specifications, arrows, or step order are shown. | ITEM NO. | DESCRIPTION | PART NUMBER | QTY. | |---:|---|---|---:| | 1 | FRAME ONLY | SL-90FM | 1 | | 2 | GEARBOX | GBX-101 | 1 | | 3 | GEARBOX DRIVE SPROCKET | 41B22X78 | 1 | | 4 | GEARBOX PULLEY | PLY-25A | 1 | | 5 | GEARBOX DRIVE SPROCKET (SMALL) | 41B12X78 | 1 | | 6 | 1/2 HP 250W BLDC MOTOR | MTR-1250 | 1 | | 7 | DC MOTOR MOUNT BRACKET | MTR-B1250 | 1 | | 8 | DC MOTOR PULLEY | PLY-2 | 1 | | 9 | DC MOTOR BELT | 4L-230 (AX21) | 1 | | 10 | CONTROL BOX ASSEMBLY | CBX-AY90 | 1 | | 11 | CONTROL BOX DC CONTROL BOARD - 1/2 HP | BLDC-ULPCB | 1 | | 12 | CONTROL BOX | CBX-90 | 1 | | 13 | CONTROL BOX COVER | CBC-90 | 1 | | 14 | CONTROL BOX BRIDGE RECTIFIER | COM-1006 | 1 | | 15 | CONTROL BOX RESET PUSH BUTTON | COM-1004 | 1 | | 16 | CONTROL BOX ALARM BUZZER | COM-1005 | 1 | | 17 | CONTROL BOX LINE-IN HARNESS | COM-1016 | 1 | | 18 | CONTROL BOX RADIO RECEIVER STRIP | COM-1003 | 1 | | 19 | LIMIT SWITCH BOX ASSEMBLY | LSB-AY90 | 1 | | 20 | LIMIT BOX | LSB-103 | 1 | | 21 | LIMIT SWITCH | COM-1007 | 2 | | 22 | LIMIT SHAFT | LST-100 | 1 | | 23 | LIMIT SPROCKET | 41B15X58 | 1 | | 24 | LIMIT SWITCH WIRE HARNESS | LSH-101 | 1 | | 25 | LIMIT SHAFT BEARINGS - 5/8" | BRG-6202B | 2 | | 26 | LIMIT CHAIN | 41NPX18 | 1 | | 27 | LIMIT SWITCH PLASTIC NUT | COM-1008 | 2 | | 28 | LIMIT TABLE SPRING (2) | SPG-7575 | 2 | | 29 | LIMIT BOX PLATE | LSP-100FP | 1 | | 30 | POWER SUPPLY BOX ASSEMBLY | PSB-AY90 | 1 | | 31 | POWER SUPPLY BOX TRANSFORMER | TFR-90 | 1 | | 32 | POWER SUPPLY BOX | PSB-90 | 1 | | 33 | POWER SUPPLY BOX COVER | PSC-90 | 1 | | 34 | POWER SUPPLY BOARD | EMI-PCB | 1 | | 35 | POWER SUPPLY BOX WIRE HARNESS | PSH-90 | 1 | | 36 | POWER SUPPLY BOX ON/OFF POWER SWITCH | COM-1000 | 2 | | 37 | POWER SUPPLY BOX 110VAC OUTLET | COM-1001 | 1 | | 38 | 7 AH BATTERIES | BTY-1270 | 2 | | 39 | BATTERY BOX | BCU-90 | 1 | | 40 | BATTERY BOX COVER | BTC-90 | 1 | | 41 | BATTERY WIRE HARNESS | BTY-H90 | 1 | | 42 | FOOT PEDAL RELEASE ASSEMBLY | FPR-AY90 | 1 | | 43 | FOOT PEDAL RELEASE | FPR-90 | 1 | | 44 | FOOT PEDAL RELEASE KILL SWITCH | COM-1007P | 1 | | 45 | FOOT PEDAL SQUARE HINGE SHAFT | SHS-90FP | 1 | | 46 | FOOT PEDAL SPRING | SPG-90FP | 1 | | 47 | FOOT PEDAL SPLIT PIVOT BRACKET (2 PCS) | HSB-90FP | 1 | | 48 | FOOT PEDAL PIVOT BRACKET | HPB-90FP | 1 | | 49 | FOOT PEDAL SPRING HOOK BRACKET | SHB-90FP | 1 | | 50 | LOOP RACK | LPR-2 | 1 | | 51 | LOOP RACK WIRE HARNESS 19" | LPR-H90 | 1 | | 52 | EXTERIOR PLASTIC COVER | EPC-90 | 1 | | 53 | PLASTIC CHAIN IDLER | COM-1017 | 2 | | 54 | CHAIN BOLT (1PC) | COM-1010-1 | 1 | | 55 | CHAIN BRACKET (1PC) | COM-1009 | 1 | ALL-O-MATIC, Inc. 7820 Gloria Ave. Phone: (818) 787-1988 Van Nuys CA, USA 91406 EMAIL: fortino@allomatic.net DIMENSIONS ARE IN INCHES BREAK SHARP EDGES .10-.40 MACHINED SURFACE FINISH IS 1.6 MICROMETERS DO NOT SCALE DRAWING THE INFORMATION DISCLOSED HEREIN WAS ORIGINATED BY AND IS THE PROPERTY OF ALL-O-MATIC, INC. AND ALL PATENT, PROPRIETARY, DESIGN, USE, SALE, MANUFACTURING, AND REPRODUCTION RIGHTS THERETO ARE RESERVED BY ALL-O-MATIC, INC. TITLE: SL-90DC DRAWN BY: S. HUERTA DATE DRAWN: 08/23/2021 SHEET 1 OF 2 SCALE: 1:4 DRAWING SIZE: C ## Page 2 > Figure: Exploded component drawings for the SL-90DC. Callout balloons identify items 1–55 and leader arrows point to the corresponding parts. Sections shown: “CONTROLY BOX ASSEMBLY : CBX-AY90” (10), “LIMIT SWITCH BOX ASSEMBLY : LSB-AY90” (19), “POWER SUPPLY BOX : PSB-AY90” (30), and “FOOT PEDAL RELEASE : FPR-AY90” (42). Also shown are the exterior plastic cover (52), frame (1), motor/gearbox drive components (2–9), battery components (38–41), and chain-idler components (53–55). No dimensions, torque specifications, wire specifications beyond the 19" loop rack wire harness designation, or step order are shown. **CONTROLY BOX ASSEMBLY : CBX-AY90** — 10 Callouts: 11, 12, 13, 14, 15, 16, 17, 18, 50, 51. **LIMIT SWITCH BOX ASSEMBLY : LSB-AY90** — 19 Callouts: 20, 21, 22, 23, 24, 25, 26, 27, 28, 29. **POWER SUPPLY BOX : PSB-AY90** — 30 Callouts: 31, 32, 33, 34, 35, 36, 37. **FOOT PEDAL RELEASE : FPR-AY90** — 42 Callouts: 43, 44, 45, 46, 47, 48, 49. Callouts additionally shown: 1, 2, 3, 4, 5, 6, 7, 8, 9, 38, 39, 40, 41, 52, 53, 54, 55. ALL-O-MATIC, Inc. 7820 Gloria Ave. Phone: (818) 787-1988 Van Nuys CA, USA 91406 EMAIL: fortino@allomatic.net DIMENSIONS ARE IN INCHES BREAK SHARP EDGES .10-.40 MACHINED SURFACE FINISH IS 1.6 MICROMETERS DO NOT SCALE DRAWING THE INFORMATION DISCLOSED HEREIN WAS ORIGINATED BY AND IS THE PROPERTY OF ALL-O-MATIC, INC. AND ALL PATENT, PROPRIETARY, DESIGN, USE, SALE, MANUFACTURING, AND REPRODUCTION RIGHTS THERETO ARE RESERVED BY ALL-O-MATIC, INC. TITLE: SL-90DC DRAWN BY: S. HUERTA DATE DRAWN: 08/23/2021 SHEET 2 OF 2 SCALE: 1:4 DRAWING SIZE: C