GTO/PRO 4000 installation manual (installing the receiver)
## Page 1
> Figure: Cover page with the GTO/PRO® 4000 DC-SERIES logo, ETL Listed c/us mark, and GTO “GATES THAT OPEN” logo.
©2002 GTO, Inc.
R4000 INST
rev - 02/21/06
# Installation Manual for the
# GTO/PRO® 4000
## SINGLE Gate Operator System
## FOR PROFESSIONAL INSTALLATION ONLY!
> Figure: Warning box with warning-triangle icons.
# WARNING!
This equipment is similar to other gate or door equipment and meets or exceeds Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has hazards associated with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions. Failure to follow installation and safety instructions can result in hazards developing due to improper assembly. You agree to properly install this product and that if you fail to do so GTO, Inc. shall in no event be liable for direct, indirect, incidental, special or consequential damages or loss of profits whether based in contract tort or any other legal theory during the course of the warranty or at any time thereafter. The installer and/or user agree to assume responsibility for all liability and use of this product releasing GTO, Inc. from any and all liability. If you are not in agreement with this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this product for full replacement value.
**READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY** before attempting to install and use this automatic gate operator. This gate operator produces a high level of force. Stay clear of the unit while it is operating and exercise caution at all times.
All automatic gate operators are intended for use on vehicular gates only.
*This product meets and exceeds the requirements of UL 325, the standard which regulates gate operator safety, as established and made effective March 1, 2000, by Underwriters Laboratories Inc.*
3121 Hartsfield Road • Tallahassee, Florida, USA 32303
Telephone GTO Sales: 1-800-543-GATE (4283) or (850) 575-0176 • Fax (850) 575-8912
or GTO Technical Service: 1-800-543-1236 or (850) 575-4144 • Fax (850)575-8950
www.gtopro.com
## Page 2
The GTO/PRO® 4000 Gate Operator is intended for use with vehicular swing gates. The operator can be used in Class I, Class II, Class III and Class IV applications.
# VEHICULAR GATE OPERATOR CLASS CATEGORIES
**Residential Vehicular Gate Operator-Class I:** A vehicular gate operator (or system) intended for use in a home of one-to-four single family dwelling, or a garage or parking area associated therewith.
**Commercial/General Access Vehicular Gate Operator-Class II:** A vehicular gate operator (or system) intended for use in a commercial location or building such as a multifamily housing unit (five or more single family units), hotel, garages, retail store, or other building servicing the general public.
**Industrial/Limited Access Vehicular Gate Operator–Class III:** A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public.
**Restricted Access Vehicular Gate Operator–Class IV:** A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.
# Conversion Chart
*Converting Metric Units to English Equivalents*
| When You Know | Multiply By | To Find | Symbol |
|---|---:|---|---|
| centimeters | 0.3937 | inches | in. (or ") |
| meters | 3.2808 | feet | ft. (or ') |
| kilograms | 2.2046 | pounds | lb. (or #) |
*Converting English Units to Metric Equivalents*
| When You Know | Multiply By | To Find | Symbol |
|---|---:|---|---|
| inches | 2.5400 | centimeters | cm |
| feet | 0.3048 | meters | m |
| pounds | 0.4535 | kilograms | kg |
*Converting Temperature*
| When You Know | Multiply By | To Find | Symbol |
|---|---|---|---|
| deg. Celsius | (°C x 1.8) + 32 | deg. Fahrenheit | °F |
| deg. Fahrenheit | (°F-32) ÷ 1.8 | deg. Celsius | °C |
# FOR YOUR RECORDS
Please record the product serial number (located on the control box cover), and the date and place of purchase in the spaces provided below. Refer to this information when calling GTO for service or assistance with your automatic gate operator.
**Serial Number** ____________________ **Date of Purchase** ____________________
**Place of Purchase** ____________________
*Remember to keep all receipts for proof of purchase.*
## Page 3
# Table of Contents
Gate Operator Class Categories ------------------------------------------------------------inside cover
Units and Standards Conversion Chart ---------------------------------------------------inside cover
PLEASE READ THIS FIRST! --------------------------------------------------page iii
Important Safety Instructions --------------------------------------------------page 1
Disconnecting the Operator -----------------------------------------------------------page 1
Important Safety Instructions for the Consumer ------------------------------------page 2
Secondary Means of Protection Against Entrapment ------------------------------page 5
Required Safety Precautions for Gates -----------------------------------------------page 6
Warning Signs and Labels -------------------------------------------------------------page 7
Installation --------------------------------------------------------------------------page 8
Parts List ---------------------------------------------------------------------------------page 8
Technical Specifications -------------------------------------------------------------page 10
Installation Overview ---------------------------------------------------------------- page 11
Installing the Mounting Hardware ----------------------------------------------------page 12
Installing the Post Bracket Assembly -------------------------------------------page 12
Installing the Gate Bracket -------------------------------------------------------page 15
Mounting the Operator ------------------------------------------------------------page 16
Installation of the Closed Position Stop ---------------------------------------------page 16
Mounting the Control Box -------------------------------------------------------------page 17
Connecting the Operator Power Cable ----------------------------------------------page 18
Installing the Battery -------------------------------------------------------------------page 18
Powering the System --------------------------------------------------------------page 19
Solar Chart -------------------------------------------------------------------------------page 19
Connecting the Transformer -----------------------------------------------------------page 19
Control Board Settings ----------------------------------------------------------page 22
DIP Switches ----------------------------------------------------------------------------page 22
Setting the Closed Position ------------------------------------------------------------page 23
Obstruction Sensitivity -----------------------------------------------------------------page 24
Setting Your Personal Transmitter Code -------------------------------------page 25
Installing the Receiver -----------------------------------------------------------page 26
Connecting Additional Safety Devices ----------------------------------------page 27
Connecting Accessories ----------------------------------------------------------page 29
Push to Open Installation --------------------------------------------------------page 30
Maintenance & Troubleshooting Guide --------------------------------------page 33
Repair Service ---------------------------------------------------------------------page 35
Column Installation Information ----------------------------------------------page 36
Accessory Catalog ----------------------------------------------------------------page 37
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
## Page 4
# PLEASE READ THIS FIRST!
iii
Thank you for purchasing a GTO/PRO® 4000 When correctly installed and properly used, your GTO/PRO® 4000 Operator will give you many years of reliable service. Please read the following information to ensure you have the correct system for your particular needs. This manual will enable you to properly install your GTO/PRO® 4000 Automatic Gate Operator.
The GTO/PRO® 4000 Operator is designed for installation on a pull-to-open or push-to-open single leaf gate. The gate must not exceed 20 feet in length (per leaf) nor weigh more than 1000 pounds (per leaf) (please see Technical Specifications on page 10). The GTO/PRO® 4000 Operator can be used on vinyl, aluminum, chain link, farm tube, and wrought iron gates. Use on solid (wood) gates is not recommended. Solid surface gates have a high resistance to the wind. If the wind is strong enough, the operator will obstruct and stop.
The GTO/PRO® 4000 Operator accommodates extra transmitters, digital keypads, solar panels, push buttons, automatic gate locks, and other access control products. These optional accessories (see the Accessory Catalog) are available.
The GTO/PRO® 4000 Operator features adjustable obstruction sensing. This safety feature makes the gate stop and reverse direction within 2 seconds when it comes in contact with an obstruction. MIN is the factory setting; meaning the gate will exert the minimum force on an obstruction before it stops and reverses direction.
The GTO/PRO® 4000 Operator also has an adjustable auto-close feature. After the gate reaches the fully open position, it can be set to remain open up to 120 seconds before automatically closing. Pressing the transmitter button at any time after the gate opens fully will cause it to close immediately. OFF is the factory setting; meaning the gate will stay open until you press the transmitter (or keypad, etc.) again.
Please call GTO at (800) 543-GATE [4283] or (850) 575-0176 for more information about our GTO/PRO® professional line of gate operators and accessories. Our Sales Department will be glad to give you the name and phone number of a GTO/PRO® dealer near you.
# BEFORE YOU BEGIN TO INSTALL YOUR AUTOMATIC GATE OPERATOR:
Read these instructions carefully and completely to become familiar with all parts and installation steps.
You must read the installation manual for detailed instructions on gate operator safety and proper use of the gate operator.
> Figure: GTO/PRO® DC-SERIES logo.
## Page 5
> Figure: Banner with warning-triangle icons containing exclamation points and the text “IMPORTANT SAFETY INSTRUCTIONS”.
Because automatic gate operators produce high levels of force, consumers need to know the potential hazards associated with improperly designed, installed, and maintained automated gate operator systems. *Keep in mind that the gate operator is just one component of the total gate operating system.* Each component must work in unison to provide the consumer with convenience, security, and safety.
This manual contains various safety precautions and warnings for the consumer. Because there are many possible applications of the gate operator, the safety precautions and warnings contained in this manual cannot be completely exhaustive in nature. They do, however, provide an overview of the safe design, installation, and use of this product.
**CAREFULLY READ AND FOLLOW ALL SAFETY PRECAUTIONS, WARNINGS, AND INSTALLATION INSTRUCTIONS TO ENSURE THE SAFE SYSTEM DESIGN, INSTALLATION, AND USE OF THIS PRODUCT.**
Precautions and warnings in this manual are identified with this ! warning symbol. The symbol identifies conditions that can result in damage to the operator or its components, serious injury, or death.
**Because GTO automatic gate operators are *only part* of the total gate operating system, it is the responsibility of the consumer to ensure that the total system is safe for its intended use.**
### To Manually Open and Close the Gate, Follow the Procedure Below:
**⚠ CAUTION: The gate will move freely and uncontrolled when the gate operator is removed from the gate. ONLY disconnect the operator when the control box power switch is OFF and the gate is NOT moving.**
### Disconnecting the Operator
1. Turn control box power switch **OFF**.
2. Remove hairpin clip, clevis pin, and bushing from either the front or rear mounting point.
3. Remove the opener from the mount.
*The gate can be opened and closed manually when the operator is disconnected.*
> Figure: Exploded drawing of the gate operator front connection. A cylindrical operator terminates at the **Front Mount**, aligned with a **Gate Bracket**. A **Clevis Pin** inserts vertically through the connection, followed by a **Bushing** and **Hairpin Clip** below. Arrows identify: “Front Mount,” “Clevis Pin,” “Gate Bracket,” “Bushing,” and “Hairpin Clip.”
**NOTE:** Substitute a **Pin Lock** for the clevis pin on the front mount of the gate operator to prevent unauthorized removal of the operator from the gate *(see Accessory Catalog).*
> Figure: Drawing of an operator front mount attached to a gate bracket using a pin lock in place of the clevis pin.
## Page 6
> Figure: Banner with warning-triangle icons containing exclamation points and the text “IMPORTANT SAFETY INSTRUCTIONS”.
# For The Consumer
## WARNING: To reduce the risk of injury or death:
1. **READ AND FOLLOW ALL INSTRUCTIONS.** Failure to meet the requirements set forth in the instruction manual could cause severe injury and/or death, for which the manufacturer cannot be held responsible.
2. When designing a system that will be entered from a highway or main thoroughfare, make sure the system is placed far enough from the road to prevent traffic congestion.
3. The gate must be installed in a location that provides adequate clearance between it and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates **must not** open into public access areas.
4. The gate and gate operator installation **must comply with any applicable local codes.**
## I. Before Installation
1. Verify this operator is proper for the type and size of gate, its frequency of use and the proper class rating.
2. Make sure the gate has been properly installed and swings freely in both directions. Repair or replace all worn or damaged gate hardware prior to installation. A freely moving gate will require less force to operate and will enhance the performance of the operator and safety devices used with the system.
3. Review the operation of the system to become familiar with its safety features. Understand how to disconnect the operator for manual gate operation *(see page 5).*
4. This gate operator is intended for **vehicular gates ONLY.** A separate entrance or gate must be installed for pedestrian use *(see page 10).*
5. Always keep people and objects away from the gate and its area of travel. **NO ONE SHOULD CROSS THE PATH OF A MOVING GATE.**
6. Pay close attention to the diagram below and be aware of these areas at all times.
> Figure: Diagram titled “Entrapment Zones for a Pull-To-Open Application.” A driveway lies between two vertical fence/gate-post lines. A swinging gate is shown at right in the open position, with a dashed arc showing its travel into the driveway. Gray shaded areas identify **ZONE 1** at the leading edge near the left fence post, **ZONE 2** between the gate and gate post, **ZONE 3** in the gate’s path, **ZONE 4** between the open gate and an adjacent object, and **ZONE 5** at pinch points between the opener and gate/post. Labels include “Driveway” and “Gate in the Open Position.”
## Page 7
> Figure: Banner with warning-triangle icons containing exclamation points and the text “IMPORTANT SAFETY INSTRUCTIONS”.
Entrapment Zones for a proper Pull-To-Open installation:
- Zone 1 – leading edge of the gate and the fence post.
- Zone 2 – between the gate and the gate post.
- Zone 3 – the path of the gate.
- Zone 4 – the space between the gate in the open position and any object such as a wall, fence, tree, etc.
- Zone 5 – pinch points between the opener and gate or post.
## II. During Installation
1. Install the gate opener on the inside of the property and fence line. **DO NOT** install an opener on the outside of the gate where the public has access to it.
2. Be careful with moving parts and avoid close proximity to areas where fingers or hands could be pinched.
3. Devices such as contact sensors (safety edges) and non contact sensors (photo beams) provide additional protection against entrapment.
4. If push buttons or key switches are installed, they should be within sight of the gate, yet located at least 10 feet from any moving part of the gate (see diagram below). *Never install any control device where a user will be tempted to reach through the gate to activate the gate opener.*
5. Do not activate your gate opener unless you can see it and can determine that its area of travel is clear of people, pets, or other obstructions. Watch the gate through its entire movement.
6. Secure outdoor or easily accessed gate opener controls in order to prohibit unauthorized use of the gate.
> Figure: Pull-to-open gate diagram showing a gray shaded prohibited control-device area outlined with a dashed border. Text states: “Pull-To-Open Application” and “NEVER INSTALL any control device within gray area.” A gate at right swings across the driveway; its movement path is shown by a dashed arc. The central area is labeled “Moving Gate Area,” and the bottom is labeled “Driveway.” Four dimension arrows each read **10’**: horizontally from the left gate/fence area, vertically above the moving gate area, horizontally to the right of the gate/operator, and vertically below the gate. The gate operator is shown mounted inside the property line.
## Page 8
> Figure: Banner with warning-triangle icons containing exclamation points and the text “IMPORTANT SAFETY INSTRUCTIONS”.
## III. After Installation
1. Attach the warning signs (included) to each side of the gate to alert the public of automatic gate operation. It is your responsibility to post warning signs on both sides of your gate. If any of these signs or warning decals become damaged, illegible or missing, replace them immediately. Contact GTO for free replacements.
2. The gate is automatic and could move at any time, posing a serious risk of entrapment. No one should be in contact with the gate when it is moving or stationary.
3. Do not attempt to drive into the gate area while the gate is moving; wait until the gate comes to a complete stop.
4. Do not attempt to "beat the gate" while the gate is closing. This is extremely dangerous.
5. Do not allow children or pets near your gate. Never let children operate or play with gate controls. Keep the remote controls away from children and unauthorized users; store controls where children and unauthorized users do not have access to them.
6. **KEEP GATES PROPERLY MAINTAINED.** Always turn power to operator **OFF** before performing any maintenance. Clean the push-pull tube with a soft, dry cloth and apply silicone spray to it at least once per month.
7. Service the gate and gate operator regularly. Grease hinges, spray push pull tube with high quality silicon spray and replace the battery every 3-5 years.
8. To operate this equipment safely, **YOU** must know how to disconnect the operator for manual gate operation (see page 5). If you have read the instructions and still do not understand how to disconnect the operator, contact the GTO Service Department.
9. Disconnect the operator **ONLY** when the power is **TURNED OFF** and the gate is **NOT** moving.
10. Make arrangements with local fire and law enforcement for emergency access.
11. Distribute and discuss copies of the **IMPORTANT SAFETY INSTRUCTIONS** section of this manual with all persons authorized to use your gate.
12. **IMPORTANT:** Save these safety instructions. Make sure everyone who is using or will be around the gate and gate operator are aware of the dangers associated with automated gates. In the event you sell the property with the gate operator or sell the gate operator, provide a copy of these safety instructions to the new owner.
Should you lose or misplace this manual, a copy can be obtained by downloading one from the GTO/PRO® web site (www.gtopro.com), by contacting GTO, Inc., at 3121 Hartsfield Road, Tallahassee, Florida 32303 or by calling 1-800-543-4283 and requesting a duplicate copy. One will be provided to you free of charge.
## Page 9
# IMPORTANT SAFETY INSTRUCTIONS
## Secondary Means of Protection Against Entrapment
As specified by Gate Operator Safety Standard, UL 325 (30A.1.1), automatic gate operators shall have an inherent entrapment sensing system, and shall have *provisions for, or be supplied with,* at least one independent secondary means to protect against entrapment. The GTO/PRO® 4000 utilizes Type A, an inherent (i.e., built-in) entrapment sensing system as the *primary* type of entrapment protection. Also, the GTO/PRO® 4000 has *provisions for* the connection of Type B2 protection to be used as the *secondary* type of entrapment protection, if desired.
1. For gate operators utilizing a contact sensor (e.g., safety edge sensor– Type B2) in accordance with UL 325 (51.8.4 [i]):
A. One or more contact sensors shall be located at the leading edge, bottom edge, and post edge, both inside and outside of a vehicular swing gate system.
B. A hard wired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage.
C. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.
> Figure: Diagram of a vehicular swing gate with an operator/control box at the hinge-post side. Labels identify **Leading Edge Contact Sensor on both sides of the gate** at the free/leading gate edge; **Bottom Edge Contact Sensor on both sides of the gate** along the bottom; **Post Edge Contact Sensor on both sides of the gate** at the post/hinge edge; and **Vehicular Gate**. Arrows point to each sensor location.
## ENTRAPMENT ALARM (UL 325; 30A.1.1A)
The GTO/PRO® 4000 Automatic Gate Operator is designed to stop and reverse within 2 seconds when the gate comes in contact with an obstruction. Additionally, these operators are equipped with an audio entrapment alarm which will activate if the unit obstructs twice while opening or closing. This alarm will sound for a period of 5 minutes, or until the operator receives an intended signal from a hardwired entry/exit source (e.g. push button control or keypad) and the gate returns to a fully open or fully closed position. Turning the power switch on the control box OFF and back ON will also deactivate the alarm. Wireless controls such as transmitters and wireless keypads will not deactivate the alarm.
## Page 10
# IMPORTANT SAFETY INSTRUCTIONS
## Required Safety Precautions for Gates
### Install Warning Signs
*Warning signs* alert people of automatic gate operation and are **required** when installing the GTO/PRO® 4000 Automatic Gate Operator. Furthermore, a walk-through gate must be installed if pedestrian traffic is expected near the vehicular gate. We recommend using the **GTO Bulldog Pedestrian Gate Lock** (*Call the GTO Sales Department*) for controlled access.
> Figure: Diagram of a fence line with a **Pedestrian Gate** beside a **Vehicular Gate**. The pedestrian gate has a **Bulldog Pedestrian Gate Lock (recommended, not included)**. The vehicular gate has three labeled **Contact Sensor (recommended, not included)** locations: at the leading/top edge, bottom edge, and post edge. A **Warning Sign** is shown on the vehicular gate. An operator/control box is shown at the post side.
## Entrapment Protection
GTO’s inherent obstruction settings, even when properly adjusted, *may not be sensitive enough to prevent bodily injury in some circumstances.* For this reason, safety devices such as safety edge sensors (or photoelectric sensors), which stop and reverse gate direction upon sensing an obstruction, are suggested for enhanced protection against entrapment.
## Warning Signs
The warning signs *(at right)* must be installed on both sides of the gate *(see page 7 for details).*
> Figure: Warning sign with a warning triangle and the heading **WARNING**. Drawing depicts a person beside a moving gate, with an arrow showing gate movement. Text reads: **Moving Gate Can Cause Injury Or Death**.
> 1. **KEEP CLEAR!** Gate may move at any time.
> 2. Do not allow children to operate gate or play in gate area.
> 3. This gate is for vehicles only. Pedestrians must use a separate entrance.
## Page 11
# IMPORTANT SAFETY INSTRUCTIONS
> Figure: Large warning sign. Header: warning-triangle icon and **WARNING**. Drawing shows a person beside a gate with a left-pointing arrow indicating movement. Text:
> **Moving Gate Can Cause Injury Or Death**
> 1. **KEEP CLEAR!** Gate may move at any time.
> 2. Do not allow children to operate gate or play in gate area.
> 3. This gate is for vehicles only. Pedestrians must use a separate entrance.
>
> Caption: *Warning signs (2 enclosed) to be installed on each side of the gate (3–5 feet above the bottom of the gate).*
These warning labels should be found at the locations specified below. If any of them are missing, immediately contact GTO for replacements.
> Figure: Product identification and manual operation instruction label. Includes ETL Listed mark and:
> **GTO DC SW-4000 SERIES**
> **Conforms to UL 325 STANDARDS**
> Maximum Gate: 1000 lb. (453.5 kg); 20 ft. (6.1 m)
> Voltage: 12 Vdc; Frequency: 0 Hz; Power: 60 W
> Class I, II, III and IV Vehicular Swing Gate Operator.
> Serial Number: XXXXXXXXXX
>
> **TO MANUALLY OPEN AND CLOSE THE GATE:**
> 1. Turn control box power switch OFF.
> 2. Disconnect front or rear mount from gate bracket.
> 3. Pull operator away from front or real mounts.
>
> **Disconnect operator ONLY when the control box power switch is OFF and the gate is NOT moving.**
>
> GTO, Inc. Tallahassee, Florida USA
>
> Caption: *Product identification and manual operation instruction label (1) installed on control box.*
> Figure: Two labels installed on operator housing: a **GTO/PRO® 4000** logo label reading **DC-SERIES**, **1-800-543-GATE (4283)**, and **www.gtopro.com**; and a warning label reading **WARNING**, **MOVING GATE Can Cause Injury or Death**, with a gate/person drawing, left-pointing arrow, and the three warning instructions. Caption: *Logo and warning labels (2) installed on each side of operator housing.*
## Page 12
# Single Gate Operator Parts List
## Operator and Mounting Hardware
> Figure: Illustrated parts layout for a single gate operator and mounting hardware. Items shown and labeled:
>
> - Gate Operator (1) w/ 6' Power Cable
> - Closed Position Stop Plate (1)
> - Post Bracket (1)
> - Post Pivot Bracket (1)
> - Gate Bracket (1)
> - Customer Support Card (1)
> - 8" Nylon Cable Tie (10)
>
> **Hardware**
>
> | Item | Quantity |
> |---|---:|
> | 1/2" x 10" Carriage Bolt | 2 |
> | 1/2" x 2-3/4" Bolt | 2 |
> | 3/8" x 3-3/4" Bolt | 2 |
> | 3/8" x 3-1/2" Clevis Pin | 1 |
> | 3/8" x 1-3/4" Clevis Pin | 1 |
> | Hairpin Clip | 2 |
> | 1/2" Washer | 4 |
> | 1/2" Lock Nut | 4 |
> | 3/8" Washer | 3 |
> | 3/18" Lock Nut | 2 |
> | 3/8" x 3/4" Bushing | 2 |
> | 3/8" x 3/16" Bushing | 2 |
> | 2" Receiver Mounting Screw | 5 |
## Page 13
# Single Gate Operator Parts List (continued)
## Control Box and Electrical Components
> Figure: Illustrated parts list showing: Transformer (1); Battery (1); GTO Transmitter (1); Receiver (1); Control Box w/ Control Board (1), with an ON/OFF switch; and Warning Signs (2). The warning sign reads: “⚠ WARNING”; “Moving Gate Can Cause Injury Or Death”; “1. KEEP CLEAR! Gate may move at any time. 2. Do not allow children to operate gate or play in gate area. 3. This gate is for vehicles only. Pedestrians must use a separate entrance.”
> Figure: Illustration of tools including open end wrenches, tape measure, level, pliers, screwdrivers, C-clamps, drill, drill bit, hacksaw, and center punch.
### Tools Needed
- Power Drill
- Open End Wrenches — 3/8", 7/16", 1/2", and 9/16"
- 3/8" Drill Bit
- Hacksaw or Heavy Duty Bolt Cutters
- Small (Flat Bladed) Screwdriver
- Phillips Screwdriver
- Tape Measure
- Level
- Wire Strippers
- C-Clamps — small, medium, and large
- Center Punch
- Extra person will be helpful
## OTHER MATERIALS YOU MAY NEED BEFORE YOU START THE INSTALLATION:
Depending on the type of gate and fence post, you may need some additional materials/hardware. Some of these items can be found in the *GTO/PRO Accessory Catalog*.
- Low voltage wire may be needed. Length depends upon the distance between the transformer power supply and the control box. See page 19, *Powering the System* and the *Accessory Catalog* for wire and solar charging panels.
- If the gate is more than 1000' away from an AC power source you will need to use at least one GTO Solar Panel to trickle charge the battery. See the *Accessory Catalog*.
- The diameter of the fence post should be at least 8" (round) or 6" (square) in order to mount the post bracket (see page 12).
- Depending upon the diameter of the fence post, you may need longer carriage bolts than those provided. Bolts should be at least 1" longer than the diameter of the fence post (see page 12).
- A horizontal or vertical cross member or mounting plate may be needed to mount the operator to the gate. See page 11.
## Page 14
# Technical Specifications
## GTO/PRO® 4000 AUTOMATIC GATE OPERATOR
### DRIVE
- Low friction screw drive (linear actuator) rated for -5 °F to +160 °F (-28 °C to +71 °C). Use of heater bans on arm and control box will enhance performance in extreme cold temperatures.
- Powered by a 12 V motor with integral case hardened steel gear reducer. Motor speed reduced to 260 rpm. Generates 820 ft.. lb. of torque at 12 V.
- Maximum opening arc of 110°. Approximate opening time (90°): 20 seconds, depending on weight of gate.
### POWER
- The system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable acid battery.
- Battery charge is maintained by a 120 Vac, 18 Vac output transformer rectified to 14.5 Vdc (40 VA) through the GTO control board. Blade-style control board fuse is rated for 25 A.
> **NOTE:** The transformer should not be *directly* connected to any battery. Do not replace fuses with higher ampere rated fuses; doing so will void your warranty and may damage your control board.
- Battery charge is maintained by GTO Solar Panel Charger: float voltage of 14.5 Vdc output from a 19 3/8" x 8 1/2" silicon alloy panel. Generates minimum of 5 W at 300 mA. A gated diode on the control board prevents battery discharge.
### CONTROL
- GTO microprocessor-based control board is set for single leaf, pull-to-open gate installations. DIP switches can be adjusted to accommodate an optional kit for push-to-open gates (see *Accessory Catalog*).
- Control board has temperature compensated circuits.
- A circuit on the control board regulates charging. "Sleep draw" is 40 mA; "active draw" is 5 to 9 A.
- Auto-memorization of digital transmitter code.
- GTO remote-mounted RF receiver tuned to 318 MHz.
- Operator length with push-pull tube fully retracted is 46 1/4", mounting point to mounting point.
- Adjustable auto-close timer (15 to 120 s), and obstruction sensitivity.
- Power terminal bock accommodates a transformer and solar panels.
- DIP switches simplify setup of gate operator.
- Accessory terminal block fully compatible with push button controls, digital keypads, safety loops, etc.
- Control board allows connection of safety edge sensors and photoelectric sensors.
- Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing.
### OPERATIONAL CAPACITY
- The Gate Capacity Chart shows approximate cycles, per day, you can expect from the GTO/PRO® 4000 Automatic Gate Operator when powered with a transformer. Actual cycles may vary slightly depending upon the type and condition of gate and installation.
> Figure: Gate Capacity Chart GTO/PRO 4000. Estimated number of cycles are based on use with a transformer and one (1) 12 Volt battery on a single gate system. Rows are gate lengths; columns are gate weights.
| Gate Length / Gate Weight | 300 lb. | 400 lb. | 500 lb. | 600 lb. | 700 lb. | 800 lb. | 900 lb. | 1000 lb. |
|---|---:|---:|---:|---:|---:|---:|---:|---:|
| 20 ft. | 135 | 130 | 125 | 120 | 115 | 110 | 105 | 100 |
| 16 ft. | 140 | 135 | 130 | 125 | 120 | 115 | 110 | 105 |
| 12 ft. | 145 | 140 | 135 | 130 | 125 | 120 | 115 | 110 |
| 8 ft. | 150 | 145 | 140 | 135 | 130 | 125 | 120 | 115 |
**NOTE: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LB.**
To determine the number of cycles the gate operator will perform using solar panels, please see the specifications listed on page 19 or call (800) 543-1236 or (850) 575-4144 for more information.
\* An operation cycle is one full opening and closing of the gate.
These specifications are subject to change without notice.
## Page 15
# Installation Overview
## Pull-to-Open Gates (Gate Opens into the Property)
The diagram shown below is an example of a pull-to-open installation on a chain link fence and single gate. Mounting the operator on a masonry column requires special procedures; see **Column Installation Information on page 36** if you intend to mount the operator on a column. Furthermore, if you have a push-to-open gate, see **Push to Open Installation on page 30** before proceeding.
> Figure: Pull-to-open single chain-link gate installation diagram. Labels identify: Receiver; Control Box with Battery; Post Bracket Assembly; Single Gate Opener; Gate Bracket; Power Cable; Warning Sign; Horizontal Cross Member; “Gate Swings Evenly and Freely / Hung Firmly and Plumb”; Closed Position Positive Stop Plate; Fence Post Set in Concrete; PVC conduit (not included) to protect wire from lawn mowers and weed eaters; and a 120 Volt indoor Transformer (surge protector not supplied). A wire route is labeled: “Run 1000' (max.) of low voltage wire to control box from transformer (wire not included).”
# Preparation of the Gate
### Step 1
The gate must be plumb, level, and swing freely on its hinges. Wheels must not be attached to the gate. The gate must move throughout its arc **without binding or dragging on the ground.** *Note that gates over 250 lb. should have ball bearing hinges with grease fittings.*
### Step 2
The fence post must be secured in the ground with concrete so it will minimize twist or flex when the operator is activated. We recommend you position the operator near the **centerline** of the gate to keep the gate from twisting and flexing. The addition of a **horizontal or vertical cross member** (if one is not already in place) to provide a stable area for mounting the gate bracket is also important.
> Figure: Two chain-link gate drawings illustrating cross-member placement. The upper drawing labels a “Horizontal Cross Member” across the gate. The lower drawing labels a “Vertical Cross Member” at the gate center.
## Page 16
# Installing Mounting Hardware
## Installing the Post Bracket Assembly
The post bracket is designed to work on a *flat* fence post. Fence posts must be at least 6" square in order to mount the post bracket.
> **NOTE:** The best method of attaching the post bracket to metal post is welding. Round wood posts (no smaller than 8" diameter) may be notched to create a flat surface for attaching the post bracket.
If bolts are used to mount the post bracket, the bolts must *completely* penetrate the fence post. If your fence post is wider than 8", it will be necessary to use carriage bolts longer than those supplied. On **wood** posts use a metal plate (not provided) between the nuts and post to prevent the operator from pulling the bolts and washers through the wood.
On masonry columns use red heads or other secure masonary mounting hardware.
> **NOTE:** A fence post smaller than 6" in diameter or 6" square should be made of metal instead of wood so that it will remain stable while the operator is moving the gate.
> Figure: Post bracket assembly mounting illustration. At left, a post bracket is shown attached to a flat square post. At right, a round post is shown with a notched flat mounting surface. Two carriage bolts pass through the bracket and post; washers and nuts are shown on the opposite side. No part numbers or dimensions are labeled.
### Step 1:
Close the gate and place your level against the horizontal cross member. The top of the level should be in the center of the cross member and should overlap the fence post. Scribe a line across the cross member and fence post. You will use this line to help determine position of gate and post brackets.
> Figure: Gate and fence post drawing showing a level positioned horizontally against the center cross member. A dashed horizontal line extends across the cross member and fence post, indicating the scribed line.
## Page 17
**Step 2:**
Position the post bracket on the fence post with the mounting holes centered over the scribe line. The post bracket should be flush with the edge of the fence post closest to the gate (*see illustration*). Mark the position of post bracket holes on the fence post.
> Figure: Top-view diagram of a fence post and gate structure. A dashed horizontal scribe line passes through the post and aligns with the mounting holes of the post bracket, which is shown flush to the fence-post edge nearest the gate.
**Step 3:**
Drill holes in fence post as marked using a 1/2" drill bit. Install the post bracket using the 1/2" x 10" carriage bolts, 1/2" washers, and lock nuts (provided).
> Figure: Exploded drawing of a post bracket mounted to a rectangular fence post. Two 1/2" x 10" carriage bolts pass through the bracket and post, followed by washers and lock nuts.
**Step 4:**
Place the end of post pivot bracket with two holes inside the post bracket. Align the back hole in the post pivot bracket with back hole in the post bracket. Insert 1/2" x 3¾" hex head bolt through post pivot bracket and post bracket and secure with washer, lockwasher and nut.
> Figure: Exploded drawing showing the post pivot bracket inserted inside the post bracket on the fence post. Labels and arrows identify: “1/2" x 3-3/4" Bolt,” “Post Bracket,” “1/2" Washer,” “1/2" Lock Washer,” “1/2" Nut,” and “Post Pivot Bracket.” The bolt passes vertically through the aligned rear holes, with washer, lock washer, and nut below.
## Page 18
**Step 5:**
Position the operator rear mount between post pivot bracket. Place a small bushing under the rear mount. Align the hole in rear mount, bushing and post pivot brackets and secure with the clevis pin and hair pin clip.
> Figure: Exploded drawing of the operator rear mount connecting to the post pivot bracket. Labels identify “Clevis Pin,” “Hairpin Clip,” “Operator,” and “Small Bushing Goes Under Rear Mount.” The clevis pin is inserted downward through the aligned mounting holes and secured by the hairpin clip.
**Step 6:**
Place a small bushing under the the front mount and attach the gate bracket to the front mount using the clevis pin and hairpin clip.
> Figure: Exploded drawing of the operator front mount attached to the gate bracket. Labels identify “Front Mount,” “Clevis Pin,” “Gate Bracket,” “Small Bushing Goes Under Front Mount,” and “Hairpin Clip.” The clevis pin passes through the gate bracket and front mount, with the bushing beneath the front mount and hairpin clip securing the pin.
**Step 7:**
Open the gate to the desired open position. Position the operator so that the gate bracket rests against the gate along the level scribed line. Check the clearance between the operator and the gate. The operator should only make contact with the gate at the gate bracket. See illustration at right for examples of clearance.
When you feel that you have the best position for the post pivot bracket in the open position, insert the bolt through the aligned holes of the post bracket and post pivot bracket to hold it in place.
Clamp the gate bracket to the gate using c-clamps or another type of clamp.
> Figure: Diagram labeled “Gate in the OPENED POSITION,” showing the operator and gate in an open configuration. Arrows identify a “Pinch Area” between the operator and gate and show “2" minimum” clearance.
> Figure: Boxed notice reading: “IMPORTANT: While determining the position of the post pivot bracket, be sure that the position allows for minimum 2 inches of clearance between the gate and the operator in both the open and closed positions, as shown in Steps 7 & 8. This clearance will give the operator the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area.”
## Page 19
**Step 8:**
Remove the clevis pin from the front mount and while supporting the gate operator, swing the gate and gate operator to the closed position. With the gate and gate operator in the closed position check the clearance and be sure that the gate operator is not binding at the post pivot bracket.
If you don't have 2 inches of clearance or the gate operator is binding on the post pivot bracket, remove the bolt in the post bracket and readjust the pivot bracket until you can achieve the proper clearance.
With the post pivot bracket in the optimum position for clearance and freedom of movement, replace the bolt in a post bracket adjustment hole and return the operator to the open position and recheck the gate operator level and clearance. Make sure the gate bracket is clamped securely.
> Figure: Diagram labeled “Gate in the CLOSED POSITION,” showing the gate operator in the closed configuration. Arrows identify the “Pinch Area” and indicate “2" minimum” clearance between the gate and operator.
# Installing the Gate Bracket
**Step 9:**
Move the operator away from the gate bracket. The mounting holes should be centered over the scribe line. Mark the gate in the center of the gate bracket holes. Remove the gate bracket and drill the 1/2" holes in the gate cross member and attach the gate bracket using the 1/2" x 2¾" bolts, washers and nuts.
> Figure: Drawing of a gate operator, gate bracket, and cylindrical horizontal gate cross member. The cross member is labeled “LEVEL horizontal cross member.” Dashed lines extend from the gate-bracket slots to the cross member. Label reads: “Mark cross member through middle of gate bracket slots and drill 1/2" holes.”
> Figure: Installation diagrams for a gate bracket. Left diagrams are labeled “FRONT VIEW” and “SIDE VIEW” for “Round Tube & Chain Link Gate” and “Square Tube Gate.” Right diagrams are labeled “FRONT VIEW” and “SIDE VIEW” and show a “Mounting Plate Created for Decorative Gate (required but not supplied).”
## Page 20
# Mounting the Operator
**Step 10**
Attach the operator to the securely bolted post bracket assembly and gate bracket using clevis pins, bushings, and hairpin clips, or optional Pin Locks (*see Accessory Catalog*). Verify that the operator is level and adjust the post bracket assembly if necessary.
> Figure: Perspective drawing of a gate operator mounted between a fence post and gate. Labels identify “Fence Post,” “Level Operator,” and “Clevis Pin, Bushing, and Hairpin Clip,” with arrows pointing to the connection hardware at both ends of the operator.
# Installation of the Closed Position Stop
The GTO/PRO® 4000 Gate Operator firmly holds the gate in the closed position using the positive stop plate. The positive stop helps stabilize the gate leaf in the closed position. To further enhance the stability and security of your gate, install the optional **GTO/PRO® Automatic Gate Lock** (*see Accessory Catalog*).
**Step 11**
Remove hairpin, clevis pin, and washer from front mount and close the gate (remember to support operator). Fasten the *closed position stop plate* to the end of the gate frame on the **gate centerline**, but *do not* tighten it completely. Slide the stop plate toward the fence post until they touch (*see illustration*). Once you have moved the stop plate to the correct position, tighten its hardware completely.
Use the appropriate hardware for your type of gate (use U-bolts if you have a tube or chain link gate; wood or lag screws for wood gates; etc.). This hardware is not provided.
> Figure: Diagram showing the closed-position stop installation. The upper diagram shows a gate hinged at the “Gate Hinge” and stopping against the “Closed Position Stop Plate.” A curved arrow indicates: “The gate must open 80° (min.) to 110° (max.).” The lower diagrams are labeled “SIDE VIEW” and “TOP VIEW” and identify “Gate Post” and “Fence Post.” Label reads: “Closed Position Stop Plate mounted on metal post with U-bolts.”
## Page 21
At this stage of the installation, the operator should be installed on the gate and the closed position stop should be in place.
### Check List
- The gate is plumb, level, and swings smoothly on its hinges.
- A plate or support was added for the gate bracket (if necessary).
- The operator is level and mounted on the centerline of the gate.
# Mounting the Control Box
### Step 1
Mount the control box using the screws *(provided)* or another secure mounting method. The control box must be mounted at least **3 feet above the ground** to protect it from rain splash, snow, etc., and at least **3 feet from an AC power source to prevent electrical interference.**
> Figure: Drawing of an open control box mounted on a vertical post. Four arrows point to the box mounting holes/screws. Label: “Use mounting holes and screws provided to mount control box to a secure surface.” The control board is visible inside the box.
## Page 22
# Connecting Operator Power Cable
### Step 2
Strip approximately 3/16" of insulation from each wire of the operator power cable. Twist each exposed wire tightly (there are seven [7] wires inside the power cable sheath). Loosen sealing nut on strain relief hub at bottom of control box. Insert power cable into control box through strain relief. Thread approximately 6" of the power cable into the control box and retighten sealing nut until the power cable locks into place.
> Figure: Open control box drawing showing the operator power cable entering upward through the bottom strain relief. Labels: “Strain Relief” and “Operator Power Cable.” An inset exploded drawing labels the strain-relief parts, in order: “Lock Nut,” “Hub,” and “Sealing Nut.”
### Step 3
Insert the stripped operator power cable wires into the appropriate terminals on the **OPERATOR** terminal block. The green wire should be inserted into the **GRN** terminal, the blue wire into **BLU**, the orange wire into **ORG**, black wire into **BLK**, and the red wire into the **RED** terminal.
Tighten the set screws against the end of the wires. A dab of petroleum jelly on each terminal will help prevent corrosion. Do not overtighten.
> Figure: Operator power cable with seven wires entering the MASTER INPUTS terminal block. Label: “Power cable from operator (master) arm.” Board labels include: “SWITCH,” “STALL FORCE,” “MIN,” “MAX,” “MASTER INPUTS,” “GRN,” “WHT,” “BLUE,” “BRN,” “ORG,” “RED,” “BLK,” “RECEIVER,” “COM,” “CYCLE,” “CLOSE,” “SAFETY,” “EXIT OPEN,” “SHADOW,” “LOOP,” “CLOSE EDGE,” “OPEN EDGE,” “J11,” “J8,” “J5,” “J13,” and “J12.”
> Figure: Three terminal-block wire-installation diagrams labeled “Correct,” “Wrong,” and “Wrong.” Each labels “Wire” and “Terminal Block.” The correct diagram shows the stripped wire fully inserted under the terminal screw; the wrong diagrams show improper wire placement.
# Installing the Battery
### Step 4
Make sure the control box power switch is in the **OFF** position. The ON/OFF Switch is located on the bottom of the control box. Remove the control box cover and slide the battery into position with its terminals to the **RIGHT** *(see illustration)*. Connect the **BLACK** battery wire to the **NEGATIVE (–)** battery terminal. Connect the **RED** battery wire to the **POSITIVE (+)** terminal. *Pay close attention to the color of the wires. If the wires are connected incorrectly, the control board may be damaged.* **NEVER insert the battery with the terminals to the left.**
> Figure: Battery drawing with its terminals on the right. The upper terminal is marked “+” and the lower terminal “–.” Labels: “BLACK wire to NEGATIVE (—) terminal”; “RED wire to POSITIVE (+) terminal”; “BLACK”; “RED.”
> Figure: Note box with two control-box battery-placement drawings. Text: “NOTE: The battery that came with your GTO/PRO® 4000, MUST be placed horizontally battery with the terminals on the RIGHT. If an optional second battery is needed, both batteries must be placed vertically with terminals at the bottom. An optional second battery can be used for solar and/or high traffic applications, if needed.” Drawings labeled: “Single Battery Installed Horizontally with terminals on the right.” and “Dual Batteries Installed Vertically with terminals on bottom.”
## Page 23
# Powering the System
# Installation of the Transformer
**IMPORTANT:**
- The transformer is designed and intended for **indoor** use. If the transformer can be plugged only into an outside electrical outlet, a weatherproof cover or housing (available at local electrical supply stores) must be used.
- All low voltage wire used with the GTO/PRO® 4000 Gate Operator must be 16 gauge dual conductor, multi-stranded, direct burial wire *(see page 20)* and the *Accessory Catalog*. **Do not run more than 1000 feet of wire.**
- If your gate is more than 1000 ft. from an ac power source, you will need to use at least one 5 watt Solar Panel to charge the battery *(see Accessory Catalog)*. Refer to the **Solar Panels and Gate Activity** chart below.
# Optional Solar Panels and Gate Activity
The table and map illustrate the maximum number of gate cycles to expect per day in a particular area when using from 10 to 30 watts of solar charging power. *(see Accessory Catalog).* The figures shown are for winter (minimum sunlight) and do not account for the use of any accessory items. *Accessories connected to your system will draw additional power from the battery.*
**NOTE:** A minimum of 10 watts of solar charging power is required for GTO/PRO 4000 single gate systems, with a maximum of 30 watts. An optional second battery can be used for solar and/or high traffic applications, if needed. Consult *Solar Panel Installation Instructions for further information.*
| Winter Ratings | Zone 1 | Zone 2 | Zone 3 |
|---|---:|---:|---:|
| 12 v single gate (10 watts) solar charger | 4 | 8 | 13 |
| 12 v single gate (15 watts) solar charger | 6 | 12 | 20 |
| 12 v single gate (20 watts) solar charger | 8 | 16 | 26 |
| 12 v single gate (25 watts) solar charger | 10 | 20 | 32 |
| 12 v single gate (30 watts) solar charger | 12 | 24 | 46 |
> Figure: Drawing of a solar panel on a pole beside a map of the United States, including Alaska and Hawaii. Map zones are labeled “Zone 1,” “Zone 2,” and “Zone 3.” Zone 1 covers northern/central areas; Zone 2 is below it across central/eastern areas; Zone 3 covers the southwest, southern Florida area, Alaska, and Hawaii.
### Step 1
Make sure the power switch is **OFF** before proceeding to the next step.
### Step 2
Select the electrical outlet into which you will plug the transformer. Measure the distance from this outlet to the control box following the path where the wire will be laid. After you have measured how much wire is needed, cut the wire to the appropriate length.
> Figure: Bottom/open view of control box enclosure. An arrow identifies the circular switch labeled “ON/OFF Switch”; switch face is marked “ON/OFF.”
## Page 24
# IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE
The only wire acceptable for use with GTO products is 16 gauge multi-stranded, low voltage, PVC sheathed wire. This particular gauge enables the transformer to provide an adequate charge through the control board to the battery at distances up to 1000 ft.
**DO NOT** use telephone wire or solid core wire. Unlike multi-stranded wire, these types of wire are inadequate for use with your gate operator system. Telephone wire and solid core wire do not deliver enough voltage for your gate operator to function and will cause the system to go into a condition known as "low voltage lockout."
**NEVER** splice wires together. Splicing permits corrosion and seriously degrades the wire's ability to carry an adequate current.
### Step 3
Lay the measured length of low voltage wire in a trench following a path from the selected electrical outlet to the control box. Wires coming up from the ground should be run through PVC conduit to protect them from lawn mower blades, weed eaters, and grazing animals. Be sure to bury the wire laid in the trench.
### Step 4
Feed the low voltage wires upward through the strain relief opening on the lower left of the control box. Pull 6" to 8" of wire into the control box and tighten the strain relief screw to secure the wires.
> Figure: Open control box drawing with a battery inside, labeled “12 V Battery.” Low-voltage wire rises from a labeled “PVC Pipe” through the lower-left opening; it is labeled “Low Voltage Wire from Transformer or Solar Panel.” Operator cable enters through a separate bottom strain relief and is labeled “Operator Power Cable.” Arrow identifies “Strain Relief.”
> Figure: Warning box with warning-triangle icon: “WARNING! DO NOT PLUG THE TRANSFORMER INTO AN OUTLET DURING THIS STEP! THE TRANSFORMER MUST ONLY BE PLUGGED INTO AN OUTLET DURING STEP 7!!”
### Step 5
Strip 3/16" off the ends of the low voltage wire and twist tightly. Attach these ends to the **18VAC** terminals located on the **POWER IN** terminal block *(see illustration at right).* **Be certain not to let the exposed wires touch each other!**
Insert one transformer wire into an **18VAC** terminal. Insert the other transformer wire into the remaining **18VAC** terminal. The transformer wires can be connected to the **18VAC** terminals regardless of color.
Tighten set screws against exposed end of wires. A dab of household petroleum jelly on each terminal will help prevent corrosion.
> Figure: Control-board terminal diagram. Red and black low-voltage transformer wires point into the two terminals marked “18 VAC.” Label: “Low Voltage Wire from AC Transformer.” The POWER IN block labels include “18 VAC,” “SOLAR,” “RELAY OUT,” “~,” “~,” “–,” “+,” “NC,” “NO,” and “RLY-COM.” Additional board labels include “SLAVE INPUTS,” “MASTER INPUTS,” “GRN,” “WHT,” “BLUE,” “BRN,” “ORG,” “RED,” “BLK,” “J1,” “J2,” “J5,” “J6,” “J9,” “J13,” “J21,” and “SWITCH.” The operator master power cable is shown entering the MASTER INPUTS terminal block and labeled “Power Cable from Operator (master).”
## Page 25
### Step 6
Strip 1/2" of insulation from the ends of the low voltage wire. Attach these stripped ends to the transformer terminals.
A dab of household petroleum jelly on each terminal will help prevent corrosion.
**Make sure the exposed wires do not touch each other!**
> Figure: Drawing of a transformer with two low-voltage wires attached at its terminals. A screwdriver is shown tightening one terminal. The wire insulation is stripped at the terminal connections. No part numbers or torque specifications shown.
### Step 7
Plug the transformer into the electrical outlet.
(Use of a surge protector with the transformer is strongly recommended.)
> Figure: Drawing showing a transformer being plugged into a surge protector, which is plugged into a wall outlet. Labels: “Transformer” with an arrow pointing to the transformer; “SURGE PROTECTOR” printed vertically on the surge protector.
## Page 26
# Control Board Settings
## DIP Switches
### Main DIP Switch Settings (MODES)
#### DIP Switch #1 - Soft Start/Stop
The Soft Start/Stop feature slowly starts the gate as it begins to open and slows the gate as it comes to the closed position. This saves wear and tear on the gate and gate operator system.
#### DIP Switch #2 - Warning Buzzer
The Warning Buzzer alerts you when the gate operator is beginning to either open or close the gate. It sounds for the first 2 seconds in each direction. It also sounds a warning when the gate obstructs two times in one cycle. Switching this to OFF only disables the open and close warning not the obstruction warning.
#### DIP Switch #3 - Auto-Close
With the Auto-Close switch in the OFF position the gate will remain open until it receives another signal from an activation device such as a transmitter, keypad, or push button control. With the Auto-Close switch in the ON position the gate operator will automatically close the gate. The time the gate will remain open is determined using DIP Switches #6 and #7.
#### DIP Switch #4 - Push/Pull-to-Open
If your gate opens into the property the DIP Switch is set to OFF (factory). If your gate opens out from the property the DIP Switch must be set to the ON position.
#### DIP Switch #5 - B2/D1 Mode
This DIP Switch must remain in the OFF position unless the gate operator is going to be used by a guard or gate attendant, who can only open the gate when constant pressure is applied to a push button control device.
#### DIP Switches #6 and #7
The combination of these two switches determines the amount of time the gate will remain open when DIP Switch #3 is set in the ON position.
> Figure: Diagram of the control board and its seven-position “MODES” DIP switch. A magnified circular view labels switches 1 through 7, with ON at the top and OFF at the bottom. Arrows identify each switch setting and point from the control-board DIP switch to the enlarged switch diagram.
| DIP#6 | DIP#7 | Delay Time for Auto-Close |
|---|---|---|
| ON | ON | 15 seconds |
| ON | OFF | 30 seconds |
| OFF | ON | 60 seconds |
| OFF* | OFF* | 120 seconds (factory preset) |
**DIP#5**
| Position | Setting |
|---|---|
| ON | D1 mode, constant pressure to operate gate. |
| OFF* | B2 mode, momentary contact to operate gate. |
**DIP#4**
| Position | Setting |
|---|---|
| ON | Push-to-open operation. |
| OFF* | Pull-to-open operation. |
**DIP#3**
| Position | Setting |
|---|---|
| ON | Auto-close enabled. |
| OFF* | Auto-close disabled. |
**DIP#2**
| Position | Setting |
|---|---|
| ON* | Buzzer warning enabled. |
| OFF | Buzzer warning disabled |
**DIP#1**
| Position | Setting |
|---|---|
| ON* | Soft start enabled. |
| OFF | Soft start disabled. |
\* Factory preset
> Figure: The diagram also labels DIP#6, DIP#7, DIP#5, DIP#4, DIP#3, DIP#2, and DIP#1 with arrows from their respective switch positions. Labels include “Delay Time for Auto-Close,” “ON,” and “OFF.”
> Figure: Partial control-board drawing labels “SET LIMIT,” “LEARN TRANSMITTER,” “MODES,” “STALL FORCE,” “RECEIVER,” terminal groups “COM,” “CYCLE,” “CLOSE,” “SAFETY,” “EXIT,” “OPEN,” “SHADOW,” “LOOP,” “CLOSE EDGE,” “OPEN EDGE,” and connector labels “J11,” “J8,” and “J12.”
> Figure: Black warning box containing: “IMPORTANT CONTROL BOARD SETTINGS: CONTROL BOARD DIP SWITCH #1 is factory preset in the ON position and MUST remain in the ON position. Changing this setting can damage your gate, gate opener and possibly void your warranty!”
## Page 27
# Setting the Closed Position Limit
## TURN CONTROL BOX ON
### Your GTO/PRO® 4000 has two Limit Settings
1) **OPEN Limit setting:** (Gate in the OPEN POSITION / FACTORY SET NOT ADJUSTABLE) The open limit setting is the fully open position.
2) **CLOSED Limit setting:** (Gate in the CLOSED POSITION) To achieve optimum closed position, you are required to complete the following FOUR STEPS:
### Step 1
Confirm that the power switch is in the ON position, and the gate is in the OPEN POSITION.
### Step 2
Activate your operator by pressing the entry transmitter button. Your gate should now be moving from the fully open position toward the closed position. Prepare to STOP the gate by pressing the entry transmitter button again when the gate reaches the desired closed position. This step may be repeated until desired close position is achieved. Once the desired CLOSED position has been achieved, proceed to step 3.
### Step 3
With the gate in the desired closed position PRESS & HOLD the “SET LIMIT” button on the control board for 5 seconds.
### Step 4
Press the transmitter button and allow the gate to return to the fully open position. YOUR GATE’S CLOSED POSITION LIMIT IS NOW PROGRAMMED.
## TESTING YOUR CLOSED LIMIT SETTING:
Press your entry transmitter and allow your gate to close. If CLOSED position is not correct or needs to be changed, you will need to CLEAR your CLOSED LIMIT settings and follow Steps 1-4 again.
## CLEARING THE PROGRAMMED CLOSED LIMIT SETTING:
If you make a mistake and set the limit at the wrong position – press your transmitter to return the gate to the fully opened position, then press and hold the "SET LIMIT" button for 10 seconds. This will clear the memory for the closed limit position. Follow Steps 1-4 again.
> Figure: Drawing of a GTO/PRO® 4000 control board. An arrow labeled “Set Limit Button” points to the button marked “SET LIMIT.” Other readable labels include “MODES,” switches “1 2 3 4 5 6 7,” “ON,” “OFF,” “LEARN TRANSMITTER,” “STALL FORCE,” “MIN,” “MAX,” “RECEIVER,” “GRN,” “BLK,” “RED,” terminals “COM,” “CYCLE,” “CLOSE,” “SAFETY,” “EXIT,” “OPEN,” “SHADOW,” “LOOP,” “CLOSE EDGE,” “OPEN EDGE,” and connectors “J11,” “J8,” and “J12.”
## Page 28
# Obstruction Sensitivity Potentiometer
**IMPORTANT:** For safety reasons the obstruction setting or **Stall Force** on the GTO/PRO® 4000 control board comes from the factory set at **MIN** (minimum). In many gate installations this setting will need to be adjusted to overcome the weight and size of the gates.
The **Stall Force** potentiometer on the control board operates like a volume control on a radio. It controls the obstruction sensitivity (or the amount of force the operator will apply to an obstruction) before it automatically stops and reverses direction for approximately 2 seconds.
Use a small slotted screwdriver to turn the arrow in the center of the potentiometer. Adjust the sensitivity from the MINIMUM position where the gates operate without obstructing from there own weight or the wind conditions in your area.
**NOTE: You may need to increase the stall force in cold weather due to increased resistance from gate hinges.**
> Figure: Drawing of a GTO/PRO® 4000 control board with an arrow pointing to the “STALL FORCE” potentiometer. An enlarged circular detail shows the potentiometer, labeled “STALL FORCE,” with “MIN” on the left and “MAX” on the right. Curved arrows indicate adjustment direction between MIN and MAX. The adjustment center is shown as a screwdriver slot/arrow.
> Figure: Control-board drawing labels “DUAL MODES,” switches “1 2 3 4,” “ON,” “OFF,” “SET LIMIT,” “MODES,” switches “1 2 3 4 5 6 7,” “LEARN TRANSMITTER,” “STALL FORCE,” “MIN,” “MAX,” terminal groups “COM,” “CYCLE CLOSE,” “SAFETY,” “EXIT OPEN,” “SHADOW LOOP,” “CLOSE EDGE,” “OPEN EDGE,” receiver wires “GRN,” “BLK,” “RED,” “RECEIVER,” and connectors “J11,” “J8,” and “J12.”
**ALWAYS KEEP SAFETY AT THE TOP OF YOUR LIST WHEN ADJUSTING OR SERVICING YOUR AUTOMATIC GATE OPERATOR!**
## Page 29
# Setting Your Personal Transmitter Code
All GTO transmitters are set to a standard code at the factory and are ready to operate your GTO/PRO® 4000 Gate Operator®. For your safety and security, however, we strongly recommend that you replace the factory setting with your own personal code. Follow the directions below:
## 1. Remove the Transmitter Cover
Grasp the sides of the access cover and slide it away from the transmitter button (*see illustration*). When the access cover is removed, the battery and the DIP switches will be exposed. To set a new code, use a small screwdriver to move the switches.
> Figure: Drawing of a GTO handheld transmitter with its access cover slid away, exposing the battery compartment and DIP switch area. The transmitter bears the label “GTO.”
## 2. Set the transmitter DIP Switches
There are nine (9) transmitter DIP switches; each can be placed in three different positions (+, 0, –). **DO NOT** set all the switches in the same position, such as all +, all 0, or all –. Once the DIP switches have been set to a personal code, replace and close the access cover.
**WARNING: No other adjustments should be made inside the transmitter.**
> Figure: Drawing of a nine-switch DIP switch bank. Switch positions are marked “+”, “0”, and “–”; switches are numbered 1 through 9.
## 3. “Teach” the New Code to Control Board Memory
A. Press and hold transmitter button.
B. Press and hold the **LEARN TRANSMITTER** button on the control board for 5 seconds.
C. Release transmitter button.
D. Release **LEARN TRANSMITTER** button.
The new code is stored in control board memory.
> Figure: Control-board drawing. An arrow identifies the “Learn Transmitter Button.” Readable board labels include: J11, J8, J12; COM, COM, CYCLE CLOSE, SAFETY, EXIT OPEN, SHADOW LOOP, CLOSE EDGE, OPEN EDGE; RECEIVER; GRN, BLK, RED; STALL FORCE; MIN, MAX; TRANSMITTER; DIP switches numbered 1–7 with ON and OFF markings; SET LIMIT.
## Page 30
# Installing the Receiver
*Use the transmitter to check the range of the receiver before permanently mounting it.*
Consider the following when mounting the receiver:
- Standard receiver cable length is 10 feet (receivers with a longer cable are available as special order items; call the *GTO Sales Department*). NEVER splice receiver cable!
- **Run the cable through PVC conduit to protect it from damage.**
- DO NOT run cable through metal conduit because the receiver signal range will be decreased.
- DO NOT run cable in conduit containing ac wiring.
- DO NOT mount receiver on a metal fence or post; doing so will decrease signal range.
- The receiver range can vary from 50 to 100 feet depending upon weather, topography, and external interference.
**NOTE: Do not mount upside down.**
> Figure: Drawing of a GTO receiver mounted upright on a wooden post, secured by a screw. A long receiver cable exits the bottom and hangs downward. The receiver is labeled “GTO.”
> Figure: Boxed notice titled “FCC Regulation.”
>
> This device complies with FCC rules Part 15. Operation is subject to the following conditions:
> 1. This device may not cause harmful interference.
> 2. This device must accept an interference that may cause undesired operation.
>
> Transmitter distance may vary due to circumstances beyond our control. **NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.**
## Page 31
# Connecting Additional Safety Devices
> Figure: Boxed notice:
>
> Although GTO strongly recommends the use of additional safety devices, we do not endorse any specific brand names. Only use products that are certified and listed to be in compliance with any applicable UL standards (United Laboratories) and national and regional safety codes.
>
> Call GTO Sales at 1-800-543-4283 for information on compatible products for your specific application.
**The GTO/PRO® 4000 will ONLY accept accessory devices with normally open contact output.**
# Contact Sensors (safety edges)
**If not installing a contact sensor skip to next section.**
**PLEASE NOTE:** Contact sensors are not *included* with the GTO/PRO® 4000.
The GTO/PRO® 4000 is equipped with built-in obstruction sensitivity. The operator is designed to stop and reverse the gate within 2 seconds when it comes in contact with an obstruction. However, obstruction sensitivity, although functioning properly, *may not be sensitive enough to prevent bodily injury in some circumstances.* To augment your protection against entrapment, **GTO recommends using some form of additional safety device.** When installed, contact sensors must be mounted in compliance with UL 325, Underwriters Laboratories safety standard for gate operators. Review page 5 for information about mounting requirements for safety edges ("contact sensors").
*Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate.*
⚠ **Make sure the power switch to the operator is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the operator OFF.**
## Contact Sensor Input Connection:
Connect one of the OPEN EDGE contact sensor wires to the **COMMON (COM)** terminal and the other to the **OPEN EDGE** terminal on the GTO/PRO® 4000 control board.
Connect one of the CLOSE EDGE contact sensor wires to the **COMMON (COM)** terminal and the other to the **CLOSE EDGE** terminal on the GTO/PRO® 4000 control board.
**Activation of a contact sensor while the gate is in motion will cause the gate to stop and reverse within two (2) seconds.**
> Figure: Control-board terminal connection diagram for contact sensors. Two pairs of wires, identified by arrows, connect to the terminal strip. Labels identify “Wire from Contact Sensor (open safety edge)” and “Wire from Contact Sensor (close safety edge).” Terminal labels are COM, COM, CYCLE CLOSE, SAFETY, EXIT OPEN, SHADOW LOOP, CLOSE EDGE, OPEN EDGE, GRN, BLK, RED, and RECEIVER. Board labels include J11, J8, J12, STALL FORCE, MIN, and MAX.
## Page 32
# Non-Contact Sensors (photo beams)
**If not installing a non-contact sensor skip to next section.**
**PLEASE NOTE:** Non-contact sensors are not *included* with the GTO/PRO® 4000.
The GTO/PRO® 4000 can also accept "Safety" input from normally open "dry-contact" output devices such as photo beams connected to the SAFETY input terminal.
*Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate.*
⚠ **Make sure the power switch to the operator is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the operator OFF.**
## Non-Contact Sensor Connection:
Connect one of the non-contact sensor dry contact output wires to the **COMMON (COM)** terminal and the other to the **SAFETY** terminal on the GTO/PRO® 4000 control board.
**This input is ONLY monitored when the gate is closing. Activating the non-contact sensor (obstructing the safety beam path) will cause the gate to reverse to the fully open position.**
> Figure: Control-board terminal connection diagram for a non-contact sensor. A two-wire cable connects to the COM and SAFETY terminals. An arrow identifies “Wire from Non-Contact Sensor (photo beam).” Terminal labels are COM, COM, CYCLE CLOSE, SAFETY, EXIT OPEN, SHADOW LOOP, CLOSE EDGE, OPEN EDGE, GRN, BLK, RED, and RECEIVER. Board labels include J11, J8, J12, STALL FORCE, MIN, and MAX.
# Shadow Loop
**If not installing a shadow loop skip to next section.**
**PLEASE NOTE:** Non-contact sensors are not *included* with the GTO/PRO® 4000.
*Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate.*
⚠ **Make sure the power switch to the operator is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the operator OFF.**
## Shadow Loop Connection:
Connect one of the shadow loop wires to the **COMMON (COM)** terminal and the other to the **SHADOW LOOP** terminal on the GTO/PRO® 4000 control board.
The shadow loop is a detector located with the moving path of the gate to prevent the gate from closing when a vehicle in the path.
> Figure: Control-board terminal connection diagram for a shadow loop. A two-wire cable connects to the COM and SHADOW LOOP terminals. An arrow identifies “Wire from Shadow Loop.” Terminal labels are COM, COM, CYCLE CLOSE, SAFETY, EXIT OPEN, SHADOW LOOP, CLOSE EDGE, OPEN EDGE, GRN, BLK, RED, and RECEIVER. Board labels include J11, J8, J12, STALL FORCE, MIN, and MAX.
## Page 33
# Connecting Accessories
**If not connecting accessories skip to next section.**
The GTO/PRO® 4000 can accept NORMALLY OPEN CONTACT accessories, such as; Push Button Entry Devices and Key Pads.
*Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate.*
⚠ **Make sure the power to the operator is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the operator OFF.**
### Accessory Input Connection:
Connect one of the accessory wires to the COMMON (COM) terminal and the other to the CYCLE CLOSE terminal on the GTO/PRO® 4000 control board.
**Each activation of the accessory will cause the gate to cycle as follows:**
→ OPEN → STOP → CLOSE → STOP →
> Figure: Control-board terminal illustration. Two wires labeled “Wire from Accessory (push button, key pad, etc.)” connect to the two leftmost terminals labeled “COM” and “COM.” Terminal strip labels, left to right: COM, COM, CYCLE CLOSE, SAFETY, EXIT OPEN, SHADOW LOOP, CLOSE EDGE, OPEN EDGE. Board connector labels: J11, J8, J12. Receiver terminals are labeled GRN, BLK, RED and “RECEIVER.” A stall-force dial is labeled “STALL FORCE,” “MIN,” and “MAX.”
# Output Relay
The output relay provides N/O and N/C contact. N/O contact functions only when gate is moving. N/C contact functions only when gate is at rest. Relay can switch up to 36 volts A/C or D/C and can be used for strobe type warning lights, to turn on safety beams, etc.
## Page 34
# Push to Open Installation
## Determining The Mounting Position of The Post Bracket Assembly
⚠ **Swinging gates shall not open into public access areas!**
A "Push-to-Open" gate opens out from the property.
If you have a pull-to-open gate (gate opens *into* the property), return to page 12.
In a PUSH-TO-OPEN installation the operators are installed while the gates are in the **closed** position.
**NOTE:** An optional 12" long Post Pivot Bracket (R4KPTO) is available for installations that need a greater distance to achieve the safe gate and gate operator clearance (2 inches).
### Step 1
With the gates closed, adjust the post bracket assembly and the gate bracket until the operator is level. While holding the operator level, use C-clamps to temporarily keep the post bracket assembly and gate bracket in their respective positions on the fence post and gate.
> Figure: Exploded drawing of a post bracket mounted to a square post and connected to a post pivot bracket. Labels and arrows identify: “1/2" x 3-3/4" Bolt,” “Post Bracket,” “1/2" Washer,” “1/2" Lock Washer,” “1/2" Nut,” and “Post Pivot Bracket.”
**IMPORTANT:** While determining the mounting point for the post pivot bracket assembly be sure that the position allows for maximum clearance between the gate and the operator in both the open and closed positions, as shown in the diagrams below. This clearance will give the operator the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area.
### Step 2
After verifying that you have the best position for the post pivot bracket, insert the 5/16" x 1 3/4" bolt through the aligned holes of the post bracket and post pivot bracket and fasten it with the 5/16" washer and nut.
**IMPORTANT:** If you loosened the clamp on the post bracket to achieve the optimum position, tighten it in its new position and recheck the gate bracket with the gate in the open position (move the gate bracket and re-clamp it if necessary).
> Figure: Two gate/operator clearance diagrams. The upper diagram is labeled “Gate in the Open Position” and identifies a “Pinch Area” between the gate and operator, with a “2" minimum” clearance dimension. The lower diagram is labeled “Gate in the Closed Position,” identifies a “Pinch Area,” and shows a “2" minimum” clearance between the gate and operator.
## Page 35
### Step 3
With the gate in the **fully closed position** and the operator retracted, swing the operator to the gate. Mark reference points for bolt holes on gate cross member through middle of gate bracket slots. The operator must be level. Drill 3/8" holes into the gate cross member as marked. Fasten gate bracket to cross member using (2) 3/8" x 3" bolts, washers, lock washers, and nuts. Attach the operator to the post bracket assembly and gate bracket using clevis pins, bushings, and hairpins clips.
> Figure: Drawing of an operator installed between a fence post and gate cross member. Arrows label “Fence Post,” “Level Operator,” and “Clevis Pin, Bushing, and Hairpin Clip.” The operator is shown level, with clevis-pin connections at both ends.
### Step 4
Make sure the control box power switch is **OFF**. Use a small screwdriver to move the **Number 4 DIP** switch from the factory setting (OFF / Pull-To-Open) to **ON for Push-To-Open**. Turn power switch ON. The control board is now configured to *push* the gate open.
> Figure: Control-board drawing with a magnified DIP-switch bank numbered 1 through 7. An arrow identifies DIP#4. The switch positions are marked ON and OFF. Text reads: “DIP#4 — ON— Push-to-open operation. OFF— Pull-to-open operation (factory setting).”
# Setting the Open Position Limit
### Step 1
Confirm that the power switch is in the ON position, and the gate is in the CLOSED POSITION.
### Step 2
Activate your operator by pressing the entry transmitter button. Your gate should now be moving from the closed position toward the open position. Prepare to STOP gate by pressing the entry transmitter button again when the gate reaches the desired open position. This step may be repeated until desired close position is achieved. Once the desired OPEN position has been achieved, proceed to Step 3.
## Page 36
### Step 3
With the gate in the desired open position PRESS & HOLD the “SET LIMIT" button on the control board for 5 seconds.
### Step 4
Press the transmitter button and allow the gate to return to the closed position.
YOUR GATE’S OPEN POSITION LIMIT IS NOW PROGRAMMED.
# TESTING YOUR OPEN LIMIT SETTING:
Press your entry transmitter and allow your gate to open. If the OPEN position is not correct or need to be changed, you will need to CLEAR your OPEN LIMIT settings and follow steps one (1) to four (4) again.
# CLEARING PROGRAMMED OPEN LIMIT SETTING:
If you make a mistake and set the limit at the wrong position – press your transmitter to return the gate to the closed position, then press and hold the "SET LIMIT" button for 10 seconds. This will clear the memory for the open limit position. Follow steps one (1) to four (4) again.
> Figure: Control-board illustration with an arrow pointing to a button labeled “SET LIMIT.” The arrow caption reads “Set Limit Button.” Other readable board labels include: J11, J12, RECEIVER, GRN, BLK, RED, STALL FORCE, MIN, MAX, LEARN TRANSMITTER, and DIP switches numbered 1 through 7.
## Page 37
33
# Maintenance & Troubleshooting
If your gate operator does not function properly after it is installed, use this guide before calling the GTO Service Department.
## If the Operator Does Not Work
Check the Green LED on the Control Board:
**IF THE LED IS OFF:** This condition indicates a transformer power failure.
1. Test the transformer for voltage with a voltmeter. The acceptable range can be found in the VOLTAGE LIMITS chart on the next page. If the transformer test shows no voltage, then test the electrical outlet for voltage. If the outlet test shows voltage, then the transformer is dead and must be replaced. Allow the new transformer 12 hours to charge the battery before using the gate operator.
2. If the transformer test shows voltage, check the POWER IN terminal block on the control board for voltage. If the terminal block shows no voltage, look for broken or spliced wires.
Check the Red STATUS LED on the Control Board:
**IF THE LED IS ON:** but the unit is not working.
1. Check the battery in your transmitter and replace with a fresh one if needed..
2. Verify that the power cable is securely connected.
3. Replace the control board fuse if it is blown (25 ampere fuse only - DO NOT USE A HIGHER RATED FUSE!).
**IF THE LED IS OFF:**
1. Make sure the ON / OFF switch at the bottom of the control box is set to ON.
2. Check all connections for looseness and corrosion.
- On all gates weighing 250 lb. or more, routinely grease the ball bearing hinges at least 4 times a year; more frequently if the gates are near a coastal area.
- Keeping a few mothballs in the control box will discourage insects from entering it and damaging the control board.
- Clean the push-pull tube with a soft, dry cloth and apply silicone spray to it at least once per month.
- While oxidation is a normal part of weathering of equipment that is exposed to the elements, we recommend you apply silicone spray on the front and rear mounts to minimize this effect.
## Page 38
34
The GTO, Inc. Technical Service Department is open Monday – Friday 8:00 A.M. – 5:00 P.M. (Eastern Time)
Fax (850) 575-8950 • Web site: www.gtopro.com wwww.gtopro
Telephone (800) 543-1236
Telephone (850) 575-4144
# VOLTAGE RATINGS
## If the Operator is Working
| Item | Rating |
|---|---|
| 18 Vac Transformer | 18.0 to 22.0 Vac |
| 5 W Solar panel (single) | 18.0 to 22.0 Vdc 300 mA |
| 12 V Battery | 12.0 to 13.5 Vdc 7.0 Ah |
| Charging circuit | 12.0 to 14.8 Vdc |
measure voltage at panel and control box.
measure voltage with battery connected
> Figure: “PROFESSIONAL ACCESS SYSTEMS” logo with a registered trademark symbol.
## The Gate CLOSES Then Opens Again on its Own:
1. Check the position of the mounting brackets and readjust if necessary.
2. Check the gate for binding or hinge damage.
## The Gate OPENS Then Closes Again on its Own:
1. Check the position of the mounting brackets and readjust if necessary.
2. Check the gate for binding or hinge damage.
## Page 39
35
If your GTO/PRO® 4000 ® Gate Operator is not operating properly, please follow the steps below:
1. First use the procedures found in the Maintenance & Troubleshooting Guide (see page 33).
2. If you are unable to solve the problem, call the GTO Service Department at (800) 543-1236, or (850) 575-4144. Refer to the serial number (located on the control box cover) and date of purchase when calling for assistance.
3. If repair or replacement of your gate operator is necessary, the Service Department will assign a Return Goods Authorization (RGA) number to you.
4. Securely pack the component(s) authorized for return to the factory. Include a copy of your sales reciept for the purchase of the product(s). Write the RGA number issued to you on the outside of the package in LARGE BOLD PRINT. Ship the package(s) freight prepaid to: GTO, Inc., 3121 Hartsfield Road, Tallahassee, Florida, USA 32303.
**NOTE:** Products returned to GTO without a Return Goods Authorization (RGA) number in LARGE BOLD PRINT on the outside of the package WILL NOT be accepted. Also, items returned to GTO freight collect WILL NOT be accepted.
# Repair Service
GTO, Inc.
3121 Hartsfield Road • Tallahassee, Florida, USA 32303 • (850) 575-0176 • Fax (850) 575-8912 •
Web site www.gtopro.com
Fax (850) 575-8950 • Web site: www.gtopro.com
E-Mail: techsupport@gtoinc.com
> Figure: “PROFESSIONAL ACCESS SYSTEMS” logo with a registered trademark symbol.
## Page 40
36
# Column Installation Information
## IF THIS OPERATOR WILL BE USED WITH GATES THAT ARE MOUNTED ON MASONRY, BRICK, OR ROCK (etc.) COLUMNS:
## READ THE FOLLOWING CAREFULLY BEFORE PROCEEDING
A. The simplest solution is to install the operator in a push-to-open configuration. The minimum clearance is easier to achieve and clearance is no longer a problem, since the operator will be pushing the gate away from the column instead of pulling it toward the column. It is recommended that you place a steel plate between the operator mounting brackets and masonry surface for additional strength.
B. If a push-to-open installation is impossible due to traffic hazards, terrain, etc., another option is to re-hang the gate. You may hang it on a post, either in the center of the column or at the back corner, or move the gate to the back corner of the columns.
C. The most difficult solution is to cut a notch in the column to accommodate the operator and power cable. This job is **NOT** for the inexperienced!
> Figure: Column mount example diagram. A shaded rectangular **Column** is at left, with a horizontal **Gate** extending right from a circular **Hinge** at the column edge. A small vertical **Pivot Bracket** sits on top of the column; a right-pointing arrow labels it “Pivot Bracket.” Dashed vertical reference lines and a double-headed horizontal arrow label dimension **A** above the pivot bracket. A dashed horizontal line extends from the bracket area, and a double-headed vertical arrow labels dimension **B** down to the gate/hinge level. An upward-pointing arrow labels the circular pivot “Hinge.” Text reads: “Column Mount Example (A + B can not exceed 17 inches) Example: If A is 2" then B can not exceed 15".”
## Page 41
> Figure: Logo reading “DC-SERIES GTO/PRO® 4000.”
# ACCESSORIES
> Figure: Two solar panels mounted on tubular steel supports.
**Solar Panel (FM123), (FM122)**
The **Solar Panel** is a 10 watt solar powered battery charger for use with the all **GTO/PRO DC** gate operator systems. Particularly suited for remote installations, each **Solar Panel** comes with tubular steel support, mounting clips, wire connectors, and 8 ft. of low voltage wire (see Low Voltage Wire for additional wire). The **GTO/PRO®** control board has clearly labeled terminal connections for easy installation of the **Solar Panel**. Installation in some regions of the world will require multiple solar panels for adequate charging power. **Solar Panel (FM122) is a 5 watt solar powered battery charger with all the same features as (FM123).**
> Figure: Vertical push-button control plate with a circular button.
**Push Button Control (RB101)**
Unlit doorbell button for remote entry or exit control. Wires directly to the control board and uses 16 gauge multi-stranded, dual conductor low voltage wire (sold separately).
> Figure: Pin lock assembly with a vertical pin and lock body.
**Pin Lock (RB975)**
The **Pin Lock** substitutes for the clevis pin at the front end of the **GTO/PRO®** 1500 gate operator. Helps prevent theft of the operator from the gate, while allowing quick release of the operator.
> Figure: Key chain mini transmitter with attached key ring and keys.
**Key Chain Mini Transmitter (RB744)**
The **Key Chain Mini Transmitter** is a miniature version of the **GTO/PRO®** entry transmitter and has the same adjustable code settings. 12 Volt battery included.
> Figure: Handheld entry transmitter with two buttons.
**Entry Transmitter (RB741)**
The **GTO/PRO®** entry transmitter, with adjustable code settings, is standard equipment with all **GTO/PRO®** systems. 9 Volt battery included.
> Figure: Digital keypad mounted in a protective housing.
**Digital Keypad (F300)**
The specially designed digital keypad can be easily installed as a wireless or wired keypad. It can be programmed to use up to fifteen different personal identification number (PIN) codes. Each code is face programmable with additional security features built in. Wired installations require 16 gauge, low voltage, multi-stranded, dual conductor, direct burial wire (sold separately). Requires 3 AA batteries (not included).
> Figure: Coiled exit wand cable with a tubular wand end.
**GTO/PRO 50' Exit Wand (FM139), 100' Exit Wand (FM140), 150' Exit Wand (FM141)**
The **GTO/PRO® Exit Wand** is designed for residential and agricultural applications and is compatible with all **GTO/PRO®** automatic gate operator models. The wand is an electromagnetic sensor, which offers 'hands free' operation of the **GTO/PRO®** Gate Operators with a 12 ft. radius of detection of vehicles in motion.
> Figure: Automatic gate lock components, including a mounting bracket and lock housing labeled “GTO/PRO.”
**Automatic Gate Lock Pull-to-Open (FM144)**
A MUST for added security. Solenoid driven, with a steel housing. Unlocks and locks automatically as gates open and close. Used with **GTO/PRO®** DC swing gate operating systems for maximum stability and security. Comes with a keyed manual release. Recommended for gates over 8 ft. long. Ideal for animal enclosures or high wind areas.
> Figure: Wireless entry intercom/keypad handset in a cradle above a base unit with antenna.
**Wireless Entry Intercom / Keypad (FM136)**
Allows owner to screen guest at the gate before allowing access to the property. Keypad also allows owner to give up to 25 programmable entry codes to family, friends or approved delivery personnel. Codes can be permanent or temporary. Can be wireless or hard wired up to 1000 feet.
## Page 42
# ACCESSORIES
> Figure: Illustration of a rectangular replacement battery.
### Replacement Battery (RB500)
Standard 12 volt, 7.0 amp-hour, maintenance-free battery for the **GTO/PRO® 2000, GTO/PRO® 3000, GTO/PRO® 4000** gate operator systems. This is the only battery approved for use with the **GTO/PRO®** gate operator systems. Life expectancy is 3-5 years.
> Figure: Illustration of a coiled roll of wire with two exposed wire ends.
### Low Voltage Wire (RB509)
The 16 gauge, multi-stranded, dual conductor **Low Voltage Wire** is for connecting the AC powered transformer, or the **Solar Panel** to the control board. Also used for the connection of accessories, such as locks, keypads, push buttons and other wired control devices. This specially designed wire is UV treated, PVC coated and ready for direct burial. Available in 1000' rolls or special lengths.
> Figure: Illustration of a 12-inch push-to-open bracket with mounting holes and pivot end.
### 12" Push to Open Bracket (R4KPTO)
An optional longer Post Pivot Bracket for push-to-open installations that need a greater distance to achieve the safe gate and gate operator clearance (2 inches). Order two 12" PTO brackets for conversion of a dual swing gate installation.
> Figure: Illustration of a column mount lock receiver bracket.
### Column Mount Lock Receiver (433IH)
For mounting the **Automatic Gate Lock** on brick columns, walls, or for other applications with limited space between gate and post.
> Figure: Illustration of a replacement transformer with two prongs and terminal screws.
### Replacement Transformer (RB570)
Standard 18 volt AC transformer for maintaining the battery included with the **GTO/PRO® 3200** gate operator. This is the only transformer approved for use with all UL325 **GTO/PRO®** gate operator systems.
> Figure: Illustration of a Garage Door Receiver unit.
### Garage Door Receiver (RB709)
The Garage Door Receiver allows you to use the same **GTO/PRO®** entry transmitter (see Dual and Triple Transmitters) to operate your gate operator and your garage door operator. Compatible with most garage door operators.
> Figure: Illustration of two handheld entry transmitters: one dual-button and one triple-button transmitter.
### Dual & Triple Button Transmitters (RB742 & RB743)
The Dual (RB742) & Triple (RB743) Button Transmitters are for remote control of multiple separate gate operators, and/or gate operator(s) and garage door operator(s) (see Garage Door Receiver). 9 Volt battery included.
**If you have a question about GTO/PRO accessories
just call 1-800-543-GATE!**
The contents of all material available on this installation manual are copyrighted by GTO, Inc. (“GTO”), unless otherwise indicated. All rights are reserved by GTO, and content may not be reproduced, downloaded, disseminated, published, or transferred in any form or by any means, except with the prior, written permission of GTO. Any reprinting of GTO publications is by permission only. Copyright infringement is a violation of federal law.
GTO®, GTO/PRO®, Bulldog® are registered trademarks of GTO, Inc. Professional Access Systems™ is a trademark of GTO, Inc. and are the exclusive property of GTO, Inc. (“GTO”). All rights are reserved by GTO, and these marks may not be used, in any for without the prior, written permission of GTO.