GTO/PRO SW-2500 installation manual

## Page 1 ©2005 GTO, Inc. R2500INST rev - 04/05/06 Installation Manual for the > Figure: Cover graphic with the text “DC-SERIES GTO/PRO 2500” inside a circular outline. # Automatic Gate Operator > Figure: ETL Listed certification mark labeled “ETL,” “LISTED,” and “US.” > Figure: Warning box with warning-triangle icons and the heading “WARNING!” **WARNING!** This equipment is similar to other gate or door equipment and meets or exceeds Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has hazards associated with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions. Failure to follow installation and safety instructions can result in hazards developing due to improper assembly. You agree to properly install this product and that if you fail to do so GTO, Inc. shall in no event be liable for direct, indirect, incidental, special or consequential damages or loss of profits whether based in contract tort or any other legal theory during the course of the warranty or at any time thereafter. The installer and/or user agree to assume responsibility for all liability and use of this product releasing GTO, Inc. from any and all liability. If you are not in agreement with this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this product for full replacement value. READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to install and use this automatic gate opener. This gate opener produces a high level of force. Stay clear of the unit while it is operating and exercise caution at all times. All automatic gate operators are intended for use on vehicular gates only and should never be used by pedestrians. *This product meets and exceeds the requirements of UL 325, the standard which regulates gate opener safety, as established and made effective March 1, 2000, by Underwriters Laboratories Inc.* GTO/PRO • 3121 Hartsfield Road • Tallahassee, Florida, USA 32303 Telephone GTO/PRO Sales: 1-800-543-GATE (4283) or (850) 575-0176 • Fax (850) 575-8912 or GTO/PRO Technical Service: 1-800-543-1236 or (850) 575-4144 • Fax (850)575-8950 www.gtopro.com ## Page 2 The GTO/PRO SW-2500 Gate Opener is intended for use with vehicular swing gates. The opener can be used in Class I, Class II, Class III and Class IV applications. # VEHICULAR GATE OPENER CLASS CATEGORIES **Residential Vehicular Gate Opener-Class I:** A vehicular gate opener (or system) intended for use in a home of one-to-four single family dwelling, or a garage or parking area associated therewith. **Commercial/General Access Vehicular Gate Opener-Class II:** A vehicular gate opener (or system) intended for use in a commercial location or building such as a multifamily housing unit (five or more single family units), hotel, garages, retail store, or other building servicing the general public. **Industrial/Limited Access Vehicular Gate Opener–Class III:** A vehicular gate opener (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public. **Restricted Access Vehicular Gate Opener–Class IV:** A vehicular gate opener (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel. > Figure: Boxed “Conversion Chart.” ### Converting Metric Units to English Equivalents | When You Know | Multiply By | To Find | Symbol | |---|---:|---|---| | centimeters | 0.3937 | inches | in. (or ") | | meters | 3.2808 | feet | ft. (or ') | | kilograms | 2.2046 | pounds | lb. (or #) | ### Converting English Units to Metric Equivalents | When You Know | Multiply By | To Find | Symbol | |---|---:|---|---| | inches | 2.5400 | centimeters | cm | | feet | 0.3048 | meters | m | | pounds | 0.4535 | kilograms | kg | ### Converting Temperature | When You Know | Multiply By | To Find | Symbol | |---|---|---|---| | deg. Celsius | (°C x 1.8) + 32 | deg. Fahrenheit | °F | | deg. Fahrenheit | (°F-32) ÷ 1.8 | deg. Celsius | °C | # FOR YOUR RECORDS Please record the product serial number (located on the control box cover), and the date and place of purchase in the spaces provided below. Refer to this information when calling GTO/PRO for service or assistance with your automatic gate opener. **Serial Number** ____________________ **Date of Purchase** ____________________ **Place of Purchase** ____________________ *Remember to keep all receipts for proof of purchase.* ## Page 3 Gate Opener Class Categories -------------------------------------------------------------inside cover Units and Standards Conversion Chart ---------------------------------------------------inside cover **PLEASE READ THIS FIRST!** --------------------------------------------------page iii Important Safety Instructions --------------------------------------------------page 1 &nbsp;&nbsp;Disconnecting the Opener -------------------------------------------------------------page 1 &nbsp;&nbsp;Important Safety Instructions for the Consumer ------------------------------------page 2 &nbsp;&nbsp;Secondary Means of Protection Against Entrapment ------------------------------page 5 &nbsp;&nbsp;Required Safety Precautions for Gates -----------------------------------------------page 6 &nbsp;&nbsp;Warning Signs and Labels -------------------------------------------------------------page 7 Installation --------------------------------------------------------------------------page 8 &nbsp;&nbsp;Parts List ---------------------------------------------------------------------------------page 8 &nbsp;&nbsp;Technical Specifications -------------------------------------------------------------page 10 Installation Overview ---------------------------------------------------------------- page 11 &nbsp;&nbsp;Installation of the Mounting Hardware ----------------------------------------------page 12 &nbsp;&nbsp;Mounting the Opener -------------------------------------------------------------------page 16 &nbsp;&nbsp;Installation of the Closed Position Stop ---------------------------------------------page 16 &nbsp;&nbsp;Mounting the Control Box -------------------------------------------------------------page 17 &nbsp;&nbsp;Connecting the Power Cable ---------------------------------------------------------page 18 Powering the System --------------------------------------------------------------page 19 &nbsp;&nbsp;Solar Chart -------------------------------------------------------------------------------page 19 &nbsp;&nbsp;Connecting the Transformer -----------------------------------------------------------page 21 Control Board Settings ----------------------------------------------------------page 22 &nbsp;&nbsp;DIP Switches ----------------------------------------------------------------------------page 22 &nbsp;&nbsp;Setting the Closed Position ------------------------------------------------------------page 23 &nbsp;&nbsp;Obstuction Sensitivity ------------------------------------------------------------------page 24 Setting Your Personal Transmitter Code -------------------------------------page 25 Installing the Receiver -----------------------------------------------------------page 26 Connecting Additional Safety Devices ----------------------------------------page 27 Connecting Accessories ----------------------------------------------------------page 29 Push to Open Installation --------------------------------------------------------page 30 Maintenance & Troubleshooting Guide --------------------------------------page 33 Repair Service ---------------------------------------------------------------------page 35 Column Installation Information ----------------------------------------------page 36 Accessory Catalog ----------------------------------------------------------------page 37 # Table of Contents KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE ## Page 4 > Figure: GTO/PRO logo inside a circular outline, with the text “PROFESSIONAL ACCESS SYSTEMS.” # PLEASE READ THIS FIRST! Thank you for purchasing a GTO/PRO-SW2500 When correctly installed and properly used, your GTO/PRO-SW2500 Operator will give you many years of reliable service. Please read the following information to ensure you have the correct system for your particular needs. This manual will enable you to properly install your GTO/PRO-SW2500 Automatic Gate Operator. The GTO/PRO-SW2500 Operator is designed for installation on a pull-to-open single leaf gate (gates that open *into* the property). By purchasing an *accessory bracket*, the GTO/PRO-SW2500 Operator can accommodate a push-to-open single leaf gate (gates that open *out* from the property). The gate must not exceed 16 feet in length (per leaf) nor weigh more than 500 pounds (per leaf) (please see *Technical Specifications* on page 10). The GTO/PRO-SW2500 Operator can be used on vinyl, aluminum, chain link, farm tube, and wrought iron gates. Use on solid (wood) gates is not recommended. Solid surface gates have a high resistance to the wind. If the wind is strong enough, the operator will obstruct and stop. The GTO/PRO-SW2500 Operator accommodates extra transmitters, digital keypads, solar panels, push buttons, automatic gate locks, and other access control products. These optional accessories (see the enclosed GTO/PRO® *Accessory Catalog*) are available. The GTO/PRO-SW2500 Operator features adjustable obstruction sensing. This safety feature makes the gate stop and reverse direction within 2 seconds when it comes in contact with an obstruction. MIN is the factory setting; meaning the gate will exert the minimum force on an obstruction before it stops and reverses direction. The GTO/PRO-SW2500 Operator also has an adjustable auto-close feature. After the gate reaches the fully open position, it can be set to remain open up to 120 seconds before automatically closing. Pressing the transmitter button at any time after the gate opens fully will cause it to close immediately. OFF is the factory setting; meaning the gate will stay open until you press the transmitter (or keypad, etc.) again. Please call GTO/PRO at (800) 543-GATE [4283] or (850) 575-0176 for more information about our GTO/PRO® professional line of gate operators and accessories. Our Sales Department will be glad to give you the name and phone number of a GTO/PRO® dealer near you. iii ## Page 5 # IMPORTANT SAFETY INSTRUCTIONS Because automatic gate openers produce high levels of force, consumers need to know the potential hazards associated with improperly designed, installed, and maintained automated gate opener systems. *Keep in mind that the gate opener is just one component of the total gate operating system.* Each component must work in unison to provide the consumer with convenience, security, and safety. This manual contains various safety precautions and warnings for the consumer. Because there are many possible applications of the gate opener, the safety precautions and warnings contained in this manual cannot be completely exhaustive in nature. They do, however, provide an overview of the safe design, installation, and use of this product. **CAREFULLY READ AND FOLLOW ALL SAFETY PRECAUTIONS, WARNINGS, AND INSTALLATION INSTRUCTIONS TO ENSURE THE SAFE SYSTEM DESIGN, INSTALLATION, AND USE OF THIS PRODUCT.** Precautions and warnings in this manual are identified with this ⚠ warning symbol. The symbol identifies conditions that can result in damage to the opener or its components, serious injury, or death. **Because GTO/PRO automatic gate openers are *only* part of the total gate operating system, it is the responsibility of the consumer to ensure that the total system is safe for its intended use.** ## To Manually Open and Close the Gate, Follow the Procedure Below: ⚠ **CAUTION:** The gate will move freely and uncontrolled when the gate operator is removed from the gate. ONLY disconnect the operator when the operator power switch is OFF and the gate is NOT moving. ### Disconnecting the operator 1. Turn operator power switch OFF. 2. Remove hairpin clip, clevis pin, and bushing from the front mounting point. 3. Remove the operator from the mount. *The gate can be opened and closed manually when the operator is disconnected.* **IMPORTANT:** NEVER allow operator arm to hang by the front mount - it will break from the arm weight. **CAUTION:** Because the GTO/PRO gate operator is battery powered, disconnect the operator ONLY when the power switch on the operator is turned OFF. Unplugging the transformer does not turn power to the operator OFF. > Figure: Line drawing of a gate operator arm connected to a gate bracket. A dashed vertical alignment line shows the mounting hardware order. Labels and arrows identify: “Front or Rear Mount,” “Clevis Pin,” “Gate Bracket,” “Bushing,” and “Hairpin Clip.” The clevis pin is above the operator arm connection; the bushing is below it; the hairpin clip is at the bottom. **NOTE:** Substitute a **Pin Lock** for the clevis pin on the front mount of the gate opener to prevent unauthorized removal of the opener from the gate (*see Accessory Catalog*). > Figure: Drawing of an operator arm attached to a gate bracket using a padlock-style Pin Lock in place of the clevis pin. ## Page 6 # IMPORTANT SAFETY INSTRUCTIONS ## For The Consumer ### WARNING: To reduce the risk of injury or death: 1. **READ AND FOLLOW ALL INSTRUCTIONS.** Failure to meet the requirements set forth in the instruction manual could cause severe injury and/or death, for which the manufacturer cannot be held responsible. 2. When designing a system that will be entered from a highway or main thoroughfare, make sure the system is placed far enough from the road to prevent traffic congestion. 3. The gate must be installed in a location that provides adequate clearance between it and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates **must not** open into public access areas. 4. The gate and gate opener installation **must comply with any applicable local codes.** ### I. Before Installation 1. Verify this opener is proper for the type and size of gate, its frequency of use and the proper class rating. 2. Make sure the gate has been properly installed and swings freely in both directions. Repair or replace all worn or damaged gate hardware prior to installation. A freely moving gate will require less force to operate and will enhance the performance of the opener and safety devices used with the system. 3. Review the operation of the system to become familiar with its safety features. Understand how to disconnect the opener for manual gate operation (*see page 1*). 4. This gate opener is intended for **vehicular gates ONLY.** A separate entrance or gate must be installed for pedestrian use (*see page 6*). 5. Always keep people and objects away from the gate and its area of travel. **NO ONE SHOULD CROSS THE PATH OF A MOVING GATE.** 6. Pay close attention to the diagram below and be aware of these areas at all times. > Figure: Diagram titled “Entrapment Zones for a Pull-To-Open Application.” A driveway is shown between two vertical fence/post lines. A gate at the right is shown in the open position, with its swing path indicated by a large shaded quarter-circle and dashed arc. Labels identify “ZONE 1” at the leading edge of the closed gate near the left fence post, “ZONE 2” between the gate and gate post, “ZONE 3” in the gate travel path, “ZONE 4” in the area beside the gate in its open position, and “ZONE 5” at pinch points around the gate operator. Other labels: “Driveway” and “Gate in the Open Position.” ## Page 7 # IMPORTANT SAFETY INSTRUCTIONS Entrapment Zones for a proper Pull-To-Open installation: - Zone 1 – leading edge of the gate and the fence post. - Zone 2 – between the gate and the gate post. - Zone 3 – the path of the gate. - Zone 4 – the space between the gate in the open position and any object such as a wall, fence, tree, etc. - Zone 5 – pinch points between the opener and gate or post. ### II. During Installation 1. Install the gate opener on the inside of the property and fence line. **DO NOT** install an opener on the outside of the gate where the public has access to it. 2. Be careful with moving parts and avoid close proximity to areas where fingers or hands could be pinched. 3. Devices such as contact sensors (safety edges) and non contact sensors (photo beams) provide additional protection against entrapment. 4. If push buttons or key switches are installed, they should be within sight of the gate, yet located at least 10 feet from any moving part of the gate (see diagram below). *Never install any control device where a user will be tempted to reach through the gate to activate the gate opener.* 5. Do not activate your gate opener unless you can see it and can determine that its area of travel is clear of people, pets, or other obstructions. Watch the gate through its entire movement. 6. Secure outdoor or easily accessed gate opener controls in order to prohibit unauthorized use of the gate. > Figure: Diagram titled “Pull-To-Open Application.” A gray, dashed-outline rectangle identifies the prohibited control-device area around a moving swing gate and driveway. Center label: “Moving Gate Area.” Large warning: “NEVER INSTALL any control device within gray area.” Arrows show 10' clearances: 10' horizontally on the left side of the gate travel, 10' vertically above the moving-gate area, 10' horizontally to the right of the open gate/operator, and 10' vertically below the gate/operator. The gate swing path is shown as a dashed arc. Other label: “Driveway.” ## Page 8 # IMPORTANT SAFETY INSTRUCTIONS ### III. After Installation 1. Attach the warning signs (included) to each side of the gate to alert the public of automatic gate operation. It is your responsibility to post warning signs on both sides of your gate. If any of these signs or warning decals become damaged, illegible or missing, replace them immediately. Contact GTO/PRO for free replacements. 2. The gate is automatic and could move at any time, posing a serious risk of entrapment. No one should be in contact with the gate when it is moving or stationary. 3. Do not attempt to drive into the gate area while the gate is moving; wait until the gate comes to a complete stop. 4. Do not attempt to "beat the gate" while the gate is closing. This is extremely dangerous. 5. Do not allow children or pets near your gate. Never let children operate or play with gate controls. Keep the remote controls away from children and unauthorized users; store controls where children and unauthorized users do not have access to them. 6. **KEEP GATES PROPERLY MAINTAINED.** Always turn power to opener OFF before performing any maintenance. Clean the push-pull tube with a soft, dry cloth and apply silicone spray to it at least once per month. 7. Service the gate and gate opener regularly. Grease hinges and replace the battery every 3-5 years. 8. To operate this equipment safely, YOU must know how to disconnect the opener for manual gate operation (see page 1). If you have read the instructions and still do not understand how to disconnect the opener, contact the GTO/PRO Service Department. 9. Disconnect the opener ONLY when the power is TURNED OFF and the gate is NOT moving. 10. Make arrangements with local fire and law enforcement for emergency access. 11. Distribute and discuss copies of the IMPORTANT SAFETY INSTRUCTIONS section of this manual with all persons authorized to use your gate. 12. **IMPORTANT:** Save these safety instructions. Make sure everyone who is using or in the vicinity of the gate and gate opener are aware of the dangers associated with automated gates. In the event you sell the property with the gate opener or sell the gate opener, provide a copy of these safety instructions to the new owner. Should you lose or misplace this manual, a copy can be obtained by downloading one from the GTO/PRO web site (www.gtopro.com), by contacting GTO/PRO, at 3121 Hartsfield Road, Tallahassee, Florida 32303 or by calling 1-800-543-4283 and requesting a duplicate copy. One will be provided to you free of charge. ## Page 9 # IMPORTANT SAFETY INSTRUCTIONS ## Secondary Means of Protection Against Entrapment As specified by Gate Opener Safety Standard, UL 325 (30A.1.1), automatic gate openers shall have an inherent entrapment sensing system, and shall have provisions for, or be supplied with, at least one independent secondary means to protect against entrapment. GTO/PRO gate operators utilize *Type A*, an inherent (i.e., built-in) entrapment sensing system as the *primary* type of entrapment protection. Also, the GTO/PRO gate operator has *provisions for* the connection of *Type B2* protection to be used as the *secondary* type of entrapment protection, if desired. 1. For gate openers utilizing a contact sensor (e.g., safety edge sensor– Type B2) in accordance with UL 325 (51.8.4 [i]): A. One or more contact sensors shall be located at the leading edge, bottom edge, and post edge, both inside and outside of a vehicular swing gate system. B. A hard wired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate opener is not subjected to mechanical damage. C. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate opener for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions. > Figure: Diagram of a chain-link vehicular swing gate with an operator and control box mounted at the right post. Arrows identify **Leading Edge Contact Sensor on both sides of the gate** at the free leading edge, **Bottom Edge Contact Sensor on both sides of the gate** along the bottom edge, and **Post Edge Contact Sensor on both sides of the gate** at the hinged post edge. The gate is labeled **Vehicular Gate**. A warning sign is shown on the gate. ## ENTRAPMENT ALARM (UL 325; 30A.1.1A) The GTO/PRO Gate Opener is designed to stop and reverse within 2 seconds when the gate comes in contact with an obstruction. Additionally, these openers are equipped with an **audio entrapment alarm** which will activate if the unit obstructs **twice** while opening or closing. This alarm will sound for a period of 5 minutes, or until the opener receives an intended signal from a hardwired entry/exit source (e.g. push button control or keypad) and the gate returns to a fully open or fully closed position. Turning the power switch on the control box OFF and back ON will also deactivate the alarm. Wireless controls such as transmitters and wireless keypads will not deactivate the alarm. ## Page 10 # IMPORTANT SAFETY INSTRUCTIONS ## Required Safety Precautions for Gates ## Install Warning Signs *Warning signs* alert people of automatic gate operation and are **required** when installing the GTO/PRO gate operator. Furthermore, a walk-through gate must be installed if pedestrian traffic is expected near the vehicular gate. We recommend using the **GTO/PRO Bulldog Pedestrian Gate Lock** (*Call the GTO/PRO Sales Department*) for controlled access. > Figure: Diagram of a chain-link fence installation with a pedestrian gate at left and a vehicular gate at right. Arrows label **Pedestrian Gate**, **Bulldog Pedestrian Gate Lock (recommended, not included)**, **Contact Sensor (recommended, not included)** at the top/leading edge of the vehicular gate, **Warning Sign** on the vehicular gate, and two additional **Contact Sensor (recommended, not included)** locations along the bottom and post edge. The gate is labeled **Vehicular Gate**. A gate opener and control box are shown at the right side. ## Entrapment Protection GTO/PRO’s inherent obstruction settings, even when properly adjusted, *may not be sensitive enough to prevent bodily injury in some circumstances.* For this reason, safety devices such as safety edge sensors (or photoelectric sensors), which stop and reverse gate direction upon sensing an obstruction, are suggested for enhanced protection against entrapment. ## Warning Signs The warning signs (*at right*) must be installed on both sides of the gate (*see page 7 for details*). > Figure: Warning sign. Header reads **WARNING** with an exclamation-triangle symbol. Graphic depicts a person beside a moving gate, with a left-pointing arrow. Text reads **Moving Gate Can Cause Injury Or Death**. Listed instructions: > > 1. **KEEP CLEAR!** Gate may move at any time. > 2. Do not allow children to operate gate or play in gate area. > 3. This gate is for vehicles only. Pedestrians must use a separate entrance. ## Page 11 # IMPORTANT SAFETY INSTRUCTIONS > Figure: Large warning label. Header reads **WARNING** beside an exclamation-triangle symbol. Graphic depicts a person beside a moving gate, with a left-pointing arrow. Text reads **Moving Gate Can Cause Injury Or Death**. Listed instructions: > > 1. **KEEP CLEAR!** Gate may move at any time. > 2. Do not allow children to operate gate or play in gate area. > 3. This gate is for vehicles only. Pedestrians must use a separate entrance. Avisos de advertencia (2 suministrados) que deben instalarse uno en cada lado de la puerta (entre 90 cm y 1,5 m por encima del borde inferior de la puerta). These warning labels should be found at the locations specified below. If any of them are missing, immediately contact GTO/PRO for replacements. > Figure: GTO DC 2500 Series identification and manual-operation instruction label, with ETL Listed C US logo. Readable text: > > **GTO DC 2500 Series** > **Conforms to UL 325 STANDARDS** > Maximum Gate: 500 lb. (226.7 kg); 16 ft. (4.8 m) > Voltage: 12 Vdc; Frequency: 0 Hz; Power: 25 W > Class I, II, III and IV Vehicular Swing Gate Operator. > Serial Number: XXXXXXXXXX > > **TO MANUALLY OPEN AND CLOSE THE GATE:** > 1. Turn control box power switch OFF. > 2. Disconnect front or rear mount from gate bracket. > 3. Pull opener away from front or rear mount. > > **Disconnect operator ONLY when the control box power switch is OFF and the gate is NOT moving.** > > GTO, Inc. Tallahassee, Florida USA Número de identificación y etiqueta de instrucciones para operación manual (1) ubicados en la cubierta de la caja de control. > Figure: GTO/PRO 2500 logo and warning label intended for the opener control box. Text includes **DC-SERIES**, **GTO/PRO 2500**, **1-800-543-GATE**, and **www.gtopro.com**. The lower label reads **WARNING** and **MOVING GATE Can Cause Injury or Death**, with a gate/person graphic and left-pointing arrow. Small text states: > > 1. KEEP CLEAR! Gate may move at any time. > 2. Do not allow children to operate gate or play in gate area. > 3. This gate is for vehicles only. Pedestrians must use a separate entrance. El logo y dos (2) etiquetas de advertencia que deben ser instaladas sobre la caja del abridor, en ambos lados. ## Page 12 # Single Gate Opener Parts List ## Opener and Mounting Hardware > Figure: Illustrated parts inventory for a single gate opener. Components and quantities shown: > > - Gate Bracket (1) > - Gate Opener (1) w/ 6' Power Cable > - Closed Position Stop Plate (1) > - Post Bracket (2) > - Post Pivot Bracket (1) > - Customer Support Card (1) > - 8" Nylon Cable Tie (14) > - 3/8" x 8" Bolt (4) > - 3/8" x 3" Bolt (2) > - 3/8" x 2" Bolt (1) > - 5/16" x 1-3/4" Bolt (1) > - 3/8" x 1-1/2" Clevis Pin (2) > - Hairpin Clip (2) > - 2" Mounting Screw (5) > - 3/8" Washer (9) > - 3/8" Lock Washer (7) > - 5/16" Washer (1) > - 3/8" Nut (7) > - 5/16" Nut (1) > - 3/8" Bushings (2) ## Page 13 # Single Gate Opener Parts List (continued) ## Control Box and Electrical Components > Figure: Illustrated parts list showing: GTO Transmitter (1); Transformer (1); Battery (1); Control Box (1); Receiver (1); Warning Signs (2). Warning sign reads: “⚠ WARNING”; “Moving Gate Can Cause Injury Or Death”; “1. KEEP CLEAR! Gate may move at any time. 2. Do not allow children to operate gate or play in gate area. 3. This gate is for vehicles only. Pedestrians must use a separate entrance.” ## Tools Needed - Power Drill - Open End Wrenches — 3/8", 7/16", 1/2", and 9/16" - 3/8" Drill Bit - Hacksaw or Heavy Duty Bolt Cutters - Small (Flat Bladed) Screwdriver - Phillips Screwdriver - Tape Measure - Level - Wire Strippers - C-Clamps — small, medium, and large - Center Punch - Extra person will be helpful ## YOU MAY ALSO NEED THESE ITEMS BEFORE YOU BEGIN THE INSTALLATION *(Some of these items can be found in the Accessory Catalog page 37):* - Low voltage wire will be needed to run from the transformer to the control box; length depends upon the distance between the transformer power supply and the control box. See **Powering the System** on page 19, and the *Accessory Catalog*. - If your gate is more than 1000' away from an ac power source you will need to use at least one **GTO/PRO 5 watt Solar Panel** to trickle charge the battery. See the *Accessory Catalog*. - If your fence post is made of wood and is less than 6" in diameter or 6" square, see page 12. - If your fence post is larger than 6" in diameter you will need **threaded rods or carriage bolts longer than 8"**. See page 15. - PVC conduit. - If you have thin walled tube or panel gates, see **Recommended Reinforcement Examples** on page 12. - Depending on the type of gate, a **horizontal cross member or mounting plate** may be needed to mount the front of the opener and gate bracket to the gate. See page 11, step 2; page 15, step 10. - Surge protection for transformer. - Some types of installations require U-Bolts. - If the gate is a push-to-open refer to page 36. ## Page 14 # Technical Specifications ## GTO/PRO 2500 GATE OPERATOR ### DRIVE - Low friction screw drive (linear actuator) rated for -5 °F to +160 °F (-28 °C to +71 °C). - Powered by a 12 V motor with integral case hardened steel gear reducer. Motor speed reduced to 260 rpm. Generates 680 ft. lb. of torque at 12 V. - Maximum opening arc of 110°. Approximate opening time (90°): 20 seconds, depending on weight of gate. ### POWER - The system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable lead acid battery. - Battery charge is maintained by a 120 Vac input, 18 Vac output transformer rectified to 14.5 Vdc (40 VA) through the GTO/PRO control board. One (1) blade-style control board fuse is rated for 25 A. > **NOTE:** The transformer should not be *directly* connected to any battery. Do not replace fuses with higher ampere rated fuses; doing so will void your warranty and may damage your control board. - Battery charge is maintained by a GTO/PRO Solar Panel Charger: float voltage of 14.5 Vdc output is from a 19 3/8" x 8 1/2" silicon alloy panel. Generates a minimum of 5 W at 300 mA. A gated diode on the control board prevents battery discharge. ### CONTROL - GTO/PRO microprocessor-based control board is set for single leaf, pull-to-open gate installations. DIP switches can be adjusted to accommodate an optional kit for push-to-open gates (*see Accessory Catalog*). - Control board has temperature compensated circuits. - A circuit on the control board regulates charging. "Sleep draw" is 40 mA; "active draw" is 2 to 5 A. - Auto-memorization of digital transmitter code. - GTO/PRO remote-mounted RF receiver tuned to 318 MHz. - Opener length with push-pull tube fully retracted is 40 1/4", mounting point to mounting point. - Adjustable auto-close timer, and obstruction sensitivity. - Power terminal block accommodates a transformer or solar panels. - DIP switches simplify setup of gate opener. - Accessory terminal block is fully compatible with push button controls, digital keypads, safety loops, etc. - Control board allows connection of safety edge sensors and photoelectric sensors. - Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing. ### OPERATIONAL CAPACITY - The Gate Capacity Chart shows approximate cycles, per day, you can expect from the GTO/PRO SW-2500 Automatic Gate Operator when powered with a transformer. Actual cycles may vary slightly depending upon the type and condition of gate and installation. > **IMPORTANT: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 Lbs.** > Figure: “GTO/PRO SW2500 Gate Capacity / Cycle Chart.” Estimated number of daily cycles, based on use with a transformer and one (1) 12 Volt battery. Vertical label: “Gate Weight.” Horizontal label: “Gate Length.” Heading: “Number of Cycles Per Day.” | Gate Weight | 5' - 6' | 8' | 10' | 12' | 14' | 16' | |---|---:|---:|---:|---:|---:|---:| | 500 lbs. | 165 | 155 | 145 | 135 | 125 | 100 | | 400 lbs. | 175 | 165 | 155 | 145 | 135 | 125 | | 300 lbs. | 185 | 175 | 165 | 155 | 145 | 135 | | 200 lbs. | 195 | 185 | 175 | 165 | 155 | 145 | | 150 lbs. | 205 | 195 | 185 | 175 | 165 | 155 | | 100 lbs. | 215 | 205 | 195 | 185 | 175 | 165 | | 50 lbs. | 225 | 215 | 205 | 195 | 185 | 175 | To determine the number of cycles the gate opener will perform using solar panels, please see the specifications listed on *page 19* or call **(800) 543-1236** or **(850) 575-4144** for more information. \* An operation cycle is one full opening and closing of the gate. These specifications are subject to change without notice. ## Page 15 # Installation Overview ## Pull-to-Open Gates (Gate Opens into the Property) The diagram shown below is an example of a pull-to-open installation on a chain link fence and single gate. Mounting the opener on a masonry column requires special procedures; see **Column Installation Information** on *page 36* if you intend to mount the opener on a column. Furthermore, if you have a push-to-open gate, you will need to purchase a **push-to-open bracket** (see *Accessory Catalog*) to properly configure your system. See **Push to Open Installation** on *page 30* before proceeding. > Figure: Pull-to-open single chain-link gate installation diagram. Labels identify Receiver; Control Box with Battery; Post Bracket Assembly; Single Gate Opener; Warning Sign; Power Cable; Gate Bracket; Closed Position Positive Stop Plate; Fence Post Set in Concrete; Horizontal Cross Member; and “Gate Swings Evenly and Freely Hung Firmly and Plumb.” A 120 Volt indoor Transformer is shown, labeled “(surge protector not supplied).” Low-voltage wire runs to the control box and is labeled: “Run 1000' (max.) of low voltage wire to control box from transformer (wire not included).” PVC conduit is labeled: “PVC conduit (not included) to protect wire from lawn mowers and weed eaters.” # Preparation of the Gate ## Step 1 The gate must be plumb, level, and swing freely on its hinges. Wheels must not be attached to the gate. The gate must move throughout its arc **without binding or dragging on the ground**. *Note that gates over 250 lb. should have ball bearing hinges with grease fittings.* ## Step 2 The fence post must be secured in the ground with concrete so it will minimize twist or flex when the opener is activated. We recommend you position the opener near the **centerline** of the gate to keep the gate from twisting and flexing. The addition of a **horizontal or vertical cross member** (if one is not already in place) to provide a stable area for mounting the gate bracket is also important. > Figure: Two chain-link gate examples. Upper drawing labels a “Horizontal Cross Member” across the gate. Lower drawing labels a “Vertical Cross Member” at the gate center. ## Page 16 # Installation of Mounting Hardware The position of the post bracket determines the leverage and efficiency of the opener. The post bracket position also sets the clearance between the opener and gate in the open and closed positions (minimum 2 inches for safety reasons). The curved design of the post bracket works well for installations on round and square fence posts. Because the post bracket carries the entire thrust of the active opener, **bolts that completely penetrate the fence post must be used.** On wooden posts, place a metal plate or washer *(not supplied)* between the nuts and the fence post to prevent the thrust of the opener from pulling the bolts and washers out of the wood. > **NOTE:** A fence post smaller than 6" in diameter or 6" square should be made of metal instead of wood so that it will remain stable while the opener is moving the gate. > Figure: Round and square wooden-post mounting illustrations. Both show bolts passing through the post, with a “Metal Plate” at the bolt/nut side. Labels: “Wooden Post,” “Metal Plate,” “Post Bracket,” and “Post Pivot Bracket.” > Figure: Pull-to-open installation on a post “Larger than 6" diameter post.” The drawing labels “Center of Gate Hinge” and shows the post bracket and opener placement. Arrows indicate the center of the gate hinge. On round posts of 6" diameter or larger, the post pivot bracket may not be necessary for the installation. In this instance, the two post brackets are mounted by themselves. > **IMPORTANT:** > We strongly recommend using steel pipe, wood or metal to reinforce thin walled tube gates or wood to reinforce panel gates as shown. These reinforcement methods will prevent damage to the opener and gate when the opener is installed. # Recommended Reinforcement Examples > Figure: Three reinforcement drawings. Left: “Thin Walled Tube Gate,” with “Steel Pipe Cut in Half (not supplied)” fitted over the tube at the “Gate Bracket.” Center: tube gate reinforced with “Wood or Metal Reinforcement (not supplied)” behind the “Gate Bracket.” Right: “Panel Gate” with “1" x 6" Wood Reinforcement” and a “Gate Bracket.” ## Page 17 # Determining the Mounting Position of the Post Bracket Assembly and the Gate Bracket ### Step 3 Insert the 3/8" x 2" bolt through the center hole of the post brackets and post pivot bracket as shown. Fasten a 3/8" lock washer, 3/8" washer and 3/8" nut on the end of the bolt. DO NOT overtighten the nut because the post pivot bracket will have to be adjusted later. > Figure: Exploded drawing of the Post Bracket Assembly. Labels and arrows identify: “3/8" x 2" Bolt,” “Post Bracket,” “Post Pivot Bracket,” “3/8" Washer,” “3/8" Lock Washer,” and “3/8" Nut.” Two post brackets sandwich the post pivot bracket. > Figure: Note box: “NOTE: The following steps are intended for **pull-to-open** gate installations. If you are mounting your opener on a push-to-open gate (e.g., a gate on a sloped driveway) you will need to purchase a **Push To Open** bracket (*see Accessory catalog*). Also, see **Push-to-Open Installation** beginning on page 30.” ### Step 4 Attach post bracket assembly and gate bracket to the opener with the clevis pins and bushings. Secure the clevis pins with hairpin clips. > Figure: Rear-mount connection drawing. Labels identify “Clevis Pin,” “Bushing,” “Rear Mount,” “Opener,” “Hairpin Clip,” and “Post Bracket Assembly.” > Figure: Front-mount connection drawing. Labels identify “Front Mount,” “Clevis Pin,” “Bushing,” “Gate Bracket,” and “Hairpin Clip.” ### Step 5 With the gate in the open position (up to 110º from its closed position), and the opener fully retracted, adjust the post bracket assembly and gate bracket until the opener is level. While holding the opener level, use C-clamps to temporarily keep the post bracket assembly and gate bracket in their respective positions on the fence post and gate. > Figure: Gate opener mounted between a fence post and an open gate, held with C-clamps. Labels and arrows identify “Post Bracket Assembly,” “Level Opener,” “LEVEL horizontal cross member,” “Gate Bracket,” “Fence Post,” and “Gate In Open Position.” The illustration shows the opener level with the gate cross member. ## Page 18 **IMPORTANT:** While determining the mounting point for the post pivot bracket assembly, be sure that the position allows for a minimum of 2 inches of clearance between the gate and the opener in both the open and closed positions, as shown in the diagrams below. This clearance will give the opener the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area. ### Step 6 When you feel that you have the best position for the post pivot bracket in the open position, insert the 5/16" x 1-3/4" bolt through the aligned holes of the post bracket and post pivot bracket to hold it in place. Remove the clevis pin from the front mount and while supporting the gate opener, swing the gate and gate opener to the closed position. With the gate and gate opener in the closed position, check the clearance and be sure that the gate opener is not binding at the post pivot bracket. If you don't have 2 inches of clearance or the gate opener is binding on the post pivot bracket, remove the 5/16" x 1-3/4" bolt and readjust the pivot bracket until you can achieve these important clearances. With the post pivot bracket in the optimum position for clearance and freedom of movement, reattach the opener to the gate bracket in the open position and recheck the gate opener level and make sure the brackets are clamped securely. > Figure: Two gate-position clearance diagrams. The upper diagram is labeled “Gate in the CLOSED POSITION,” “2" minimum,” and “Pinch Area,” showing clearance between the gate and opener. An enlarged circular detail is labeled “Be sure gate opener and bracket don't bind.” The lower diagram is labeled “Gate in the OPENED POSITION,” “Pinch Area,” and “2" minimum,” showing the required clearance between the opener and gate. > Figure: Tip box: “TIP: Turning the pivot bracket over gives more hole alignment options for the post pivot bracket assembly. You can also move the entire post pivot bracket assembly to different positions on the gate post to help achieve the proper clearances.” ## Page 19 # Installing the Post Bracket Assembly and Gate ### Step 7 Mark reference points for bolt holes on the fence post through middle of bracket slots. Marking reference points in this manner allows room for adjustment when mounting the post bracket assembly and gate bracket. After marking your reference points, remove the opener and brackets from the fence and gate. ### Step 8 Drill 3/8" holes into fence post as marked. ### Step 9 Fasten post bracket assembly to the fence post using (4) 3/8" x 8" bolts, washers, lock washers, and nuts *(provided)*. Remove excess bolt length extending beyond the tightened nuts with a hacksaw or bolt cutters. **NOTE:** In cases where the fence post has a diameter larger than 6", threaded rods or carriage bolts longer than 8" *(not supplied)* must be used. > Figure: Post bracket assembly mounting diagram. Text reads “Mark fence post through middle of bracket slots and drill 3/8" holes.” The bracket assembly is shown bolted to a post with four bolts. Labels include “Post Bracket Assembly,” “SIDE VIEW,” and “Remove excess bolt length with hacksaw or bolt cutters.” > Figure: Top-view mounting examples labeled “EXAMPLES TOP VIEW”: “Round Metal Post,” “Square Metal Post,” “Square Wood Post,” and “Round Wood Post.” ### Step 10 Mark reference points for bolt holes on the gate cross member through middle of gate bracket slots. Drill 3/8" holes into the gate cross member as marked. Mount gate bracket using (2) 3/8" x 3" bolts, washers, lock washers, and nuts *(provided)*. Cut off excess bolt length extending beyond the tightened nuts. > Figure: Open-gate drawing with opener and gate bracket. Labels read “Gate In Open Position,” “LEVEL horizontal cross member,” and “Mark cross member through middle of gate bracket slots and drill 3/8" holes.” # Gate Bracket Mounting Examples > Figure: Mounting examples for “Round Tube & Chain Link Gate” and “Square Tube Gate,” with “FRONT VIEW” and “SIDE VIEW” labels. > Figure: Decorative gate mounting example. Labels read “FRONT VIEW,” “SIDE VIEW,” “Mounting Plate Created for Decorative Gate (required but not supplied),” and “Remove excess bolt length with hacksaw or bolt cutters.” ## Page 20 # Mounting the Opener ### Step 11 Attach the opener to the securely bolted post bracket assembly and gate bracket using clevis pins, bushings, and hairpin clips, or optional Pin Locks (*see Accessory Catalog*). Verify that the opener is level and adjust the post bracket assembly if necessary. > Figure: Opener mounted between fence post and gate cross member. Labels and arrows identify “Post Bracket Assembly bolted to fence post,” “Level Opener,” “LEVEL horizontal cross member,” “Gate Bracket bolted to gate cross member,” “Clevis Pin, Bushing, and Hairpin Clip” at both mounts, “Fence Post,” and “Gate In Open Position.” # Installation of the Closed Position Stop The Mighty Mule® Gate Opener firmly holds the gate in the closed position using the positive stop plate. The positive stop helps stabilize the gate leaf in the closed position. To further enhance the stability and security of your gate, install the optional Mighty Mule® Automatic Gate Lock (*see Accessory Catalog*). ### Step 12 Remove hairpin, clevis pin, and bushing from front mount and close the gate (remember to support opener). Fasten the *closed position stop plate* to the end of the gate frame on the **gate centerline**, but **do not** tighten it completely. Slide the stop plate toward the fence post until they touch (*see illustration*). Once you have moved the stop plate to the correct position, tighten its hardware completely. Use the appropriate hardware for your type of gate (use U-bolts if you have a tube or chain link gate; wood or lag screws for wood gates; etc.). **This hardware is not provided.** > Figure: Top and side views of a closed-position stop plate. Top view labels include “Gate Hinge,” “Closed Position Stop Plate,” and an arrow showing “The gate can open up to 110º (max.).” Side view labels include “Gate Post,” “Fence Post,” “SIDE VIEW,” “TOP VIEW,” and “Closed Position Stop Plate mounted on metal post with U-bolts.” ## Page 21 At this stage of the installation, the opener should be installed on the gate and the closed position stop should be in place. ### Check List - The gate is plumb, level, and swings smoothly on its hinges. - A plate or support was added for the gate bracket (if necessary). - The opener is level and mounted on the centerline of the gate. > Figure: Diagram of a single swing chain-link gate between fence sections, with an opener mounted horizontally between the post bracket assembly at the hinge post and the gate bracket. Arrows and labels identify: “Gate Swings Evenly and Freely / Hung Firmly and Plumb,” “Horizontal Cross Member,” “Post Bracket Assembly,” “Single Gate Opener,” “Gate Bracket,” “Closed Position Positive Stop Plate,” and “Fence Post Set in Concrete.” # Mounting the Control Box ### Step 13 Mount the control box using the screws *(provided)* or another secure mounting method. The control box must be mounted at least **3 feet above the ground** to protect it from rain splash, snow, etc., and at least **3 feet from an AC power source to prevent electrical interference.** > Figure: Drawing of the interior of a control box enclosure. Arrows point to mounting holes around the inside perimeter. Label: “Use mounting holes and screws provided to mount control box to a secure surface.” > Figure: Note box: “**NOTE:** The battery that came with your Mighty Mule®, **MUST** be placed in the top (horizontal) battery slot with the terminals on the **RIGHT.** The extra (vertical) battery slot is for an optional second battery. An optional second battery can be used for solar and/or high traffic applications, if needed..” ## Page 22 # Connecting Opener Power Cable ### Step 14 Make sure the control box power switch is in the **OFF** position. The ON/OFF Switch is located on the bottom of the control box. Remove the control box cover and slide the battery into position with its terminals to the **RIGHT** *(see illustration).* Connect the **BLACK** battery wire to the **NEGATIVE (–)** battery terminal. Connect the **RED** battery wire to the **POSITIVE (+)** terminal. *Pay close attention to the color of the wires. If the wires are connected incorrectly, the control board will be damaged. NEVER insert the battery with the terminals to the left.* > Figure: Drawing of a 12 Volt battery with terminals on the right. The black wire is connected to the negative (–) terminal and the red wire is connected to the positive (+) terminal. Labels: “BLACK,” “RED,” “BLACK wire to NEGATIVE (–) terminal,” and “RED wire to POSITIVE (+) terminal.” ### Step 15 Strip approximately 3/16" of insulation from each wire of the opener power cable. Twist each exposed wire tightly (there are seven [7] wires inside the power cable sheath). Loosen sealing nut on strain relief hub at bottom of control box. Insert power cable into control box through strain relief. Thread approximately 6" of the power cable into the control box and retighten sealing nut until the power cable locks into place. > Figure: Exploded diagram of a strain relief. Parts shown in order: “Lock Nut,” “Hub,” and “Sealing Nut.” The assembly is labeled “Strain Relief.” > Figure: Drawing of open control box with a 12 Volt battery installed horizontally at the top with terminals on the right. The operator power cable enters through the bottom strain relief. Labels: “12 Volt Battery (included),” “Battery wires for optional second battery,” “Space for optional second 12 Volt battery (see Accessory Catalog),” “Strain Relief,” and “Operator Power Cable.” ### Step 16 Insert the stripped power cable wires into the appropriate terminals on the **OPENER** terminal block. The green wire should be inserted into the **GRN** terminal, the blue wire into **BLU**, the orange wire into **ORG**, black wire into **BLK**, and the red wire into the **RED** terminal, white wire into **WHT**, and brown wire into **BRN**. Tighten the set screws against the end of the wires. A dab of petroleum jelly on each terminal will help prevent corrosion. > Figure: Drawing of operator power cable with seven wires entering a control board terminal block. Labels on the board include “MASTER INPUTS,” “GRN,” “WHT,” “BLUE,” “BRN,” “ORG,” “RED,” “BLK,” “COM,” “CYCLE CLOSE,” “SAFETY,” “EXIT/OPEN,” “SHADOW LOOP,” “CLOSE EDGE,” “OPEN EDGE,” “RECEIVER,” “SWITCH,” and “STALL FORCE” with “MIN” and “MAX.” Arrow label: “Power Cable from the Operator.” > Figure: Three wire-terminal-block connection diagrams labeled “Correct,” “Wrong,” and “Wrong.” Each identifies “Wire” and “Terminal Block.” The correct diagram shows the stripped wire end properly positioned under the terminal screw; the wrong diagrams show improper wire placement. ## Page 23 # Powering the System ## Installation of the Transformer ### IMPORTANT: - The transformer is designed and intended for indoor use. If the transformer can be plugged only into an outside electrical outlet, a weatherproof cover or housing (available at local electrical supply stores) must be used. - All low voltage wire used with the GTO/PRO Gate Opener must be 16 gauge dual conductor, multi-stranded, direct burial wire *(see page 20 and the Accessory Catalog).* **Do not run more than 1000 feet of wire.** - If your gate is more than 1000 ft. from an ac power source, you will need to use at least one 5 watt Solar Panel to charge the battery *(see Accessory Catalog).* Refer to the **Solar Panels and Gate Activity** chart below. # Optional Solar Panels and Gate Activity The table and map illustrate the maximum number of gate cycles to expect per day in a particular area when using from 5 to 30 watts of solar charging power. *(see Accessory Catalog).* The figures shown are for winter (minimum sunlight) and do not account for the use of any accessory items. *Accessories connected to your system will draw additional power from the battery.* **NOTE:** A maximum of 30 watts of solar charging power can be connected to the GTO/PRO Gate Opener. Consult *Solar Panel Installation Instructions for further information.* > Figure: Drawing of a solar panel on a post. | Winter Ratings | Zone 1 | Zone 2 | Zone 3 | |---|---:|---:|---:| | 12 v single gate (5 watts) solar charger | 4 | 8 | 13 | | 12 v single gate (10 watts) solar charger | 8 | 16 | 26 | | 12 v single gate (15 watts) solar charger | 11 | 20 | 30 | | 12 v single gate (20 watts) solar charger | 14 | 28 | 38 | | 12 v single gate (25 watts) solar charger | 17 | 36 | 46 | | 12 v single gate (30 watts) solar charger | 20 | 44 | 54 | > Figure: Map of the United States divided into solar charging regions, labeled “Zone 1,” “Zone 2,” and “Zone 3.” Zone 3 is also labeled over Alaska and Hawaii. ### Step 1 Make sure the power switch is **OFF** before proceeding to the next step. > Figure: Drawing of the lower side of a control box with an arrow identifying the “ON/OFF Switch.” ### Step 2 Select the electrical outlet where you will plug the transformer. Measure the distance from this outlet to the control box following the path where the wire will be laid. After you have measured how much wire is needed, cut the wire to the appropriate length. ## Page 24 ### IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE The only wire acceptable for use with GTO/PRO products is 16 gauge multi-stranded, low voltage, PVC sheathed wire. This particular gauge enables the transformer to provide an adequate charge through the control board to the battery at distances up to 1000 ft. **DO NOT** use telephone wire or solid core wire. Unlike multi-stranded wire, these types of wire are inadequate for use with your gate opener system. Telephone wire and solid core wire do not deliver enough voltage for your gate opener to function and will cause the system to go into a condition known as "low voltage lockout." **NEVER** splice wires together. Splicing permits corrosion and seriously degrades the wire's ability to carry an adequate current. ### Step 3 Lay the measured length of low voltage wire in a trench following a path from the selected electrical outlet to the control box. Wires coming up from the ground should be run through PVC conduit to protect them from lawn mower blades, weed eaters, and grazing animals. Be sure to bury the wire laid in the trench. ### Step 4 Feed the low voltage wires upward through the strain relief opening on the lower left of the control box. Pull 6" to 8" of wire into the control box and tighten the strain relief screw to secure the wires. > Figure: Drawing of an open control box. Low voltage wire from the transformer passes up through a PVC pipe and into the bottom of the box; a power cable enters from the side. Labels: “Low Voltage Wire from Transformer,” “Power Cable from Opener Arm,” and “PVC Pipe.” ### Step 5 Strip 3/16" off the ends of the low voltage wire and twist tightly. Attach these ends to the **18VAC** terminals located on the **POWER IN** terminal block *(see illustration at right).* **Be certain not to let the exposed wires touch each other!** Insert one transformer wire into an **18VAC** terminal. Insert the other transformer wire into the remaining **18VAC** terminal. The transformer wires can be connected to the **18VAC** terminals regardless of color. Tighten set screws against exposed end of wires. A dab of household petroleum jelly on each terminal will help prevent corrosion. > Figure: Warning box with warning icon: “**WARNING! DO NOT PLUG THE TRANSFORMER INTO AN OUTLET DURING THIS STEP! THE TRANSFORMER MUST ONLY BE PLUGGED INTO AN OUTLET DURING STEP 7!**” > Figure: Control board wiring diagram. Two transformer wires, labeled “RED” and “BLACK,” enter the two “18VAC” terminals. Label: “Low Voltage Wire from AC Transformer.” The board labels include “POWER IN,” “18VAC,” “SOLAR,” “RELAY OUT,” “SLAVE INPUTS,” “MASTER INPUTS,” “GRN,” “WHT,” “BLUE,” “BRN,” “ORG,” “RED,” “BLK,” “NC,” “RLY-COM,” “NO,” and “SWITCH.” A seven-wire cable is labeled “Power Cable from First Operator.” ## Page 25 ### Step 6 Strip 1/2" of insulation from the ends of the low voltage wire. Attach these stripped ends to the transformer terminals. A dab of household petroleum jelly on each terminal will help prevent corrosion. **Make sure the exposed wires do not touch each other!** > Figure: Drawing of a transformer with two low-voltage wires attached to its terminals. A slotted screwdriver is shown tightening one terminal screw. No part numbers or torque specifications shown. ### Step 7 Plug the transformer into the electrical outlet. (Use of a surge protector with the transformer is strongly recommended.) > Figure: Drawing showing a transformer plug connected to a surge protector, which plugs into a wall outlet. Labels: “Transformer” and “SURGE PROTECTOR.” > Figure: Boxed hint: > > **HINT:** Keep a few mothballs in the control box to discourage insects from entering it and damaging the control board. ## Page 26 # CONTROL BOARD SETTINGS ## DIP Switches ### Main DIP Switch Settings (MODES) **DIP Switch #1 - Soft Start/Stop** The Soft Start/Stop feature slowly starts the gate as it begins to open and slows the gate as it comes to the closed position. This saves wear and tear on the gate and gate opener system. **DIP Switch #2 - Warning Buzzer** The Warning Buzzer alerts you when the gate opener is beginning to either open or close the gate. It sounds for the first 2 seconds in each direction. It also sounds a warning when the gate obstructs two times in one cycle. Switching this to OFF only disables the open and close warning not the obstruction warning. **DIP Switch #3 - Auto-Close** With the Auto-Close switch in the OFF position the gate will remain open until it receives another signal from an activation device such as a transmitter, keypad, or push button control. With the Auto-Close switch in the ON position the gate opener will automatically close the gate. The time the gate will remain open is determined using DIP Switches #6 and #7. **DIP Switch #4 - Push/Pull-to-Open** If your gate opens into the property the DIP Switch is set to the OFF position (factory setting). If your gate opens out from the property the DIP Switch must be set to the ON position. NOTE: if you have a Push-to-Open gate application you will need a Push-to-Open bracket (see Push-to-Open Instructions on page 30). **DIP Switch #5 - B2/D1 Mode** This DIP Switch must remain in the OFF position unless the gate opener is going to be used by a guard or gate attendant, who can only open the gate when constant pressure is applied to a push button control device. **DIP Switches #6 and #7** The combination of these two switches determines the amount of time the gate will remain open when DIP Switch #3 is set to the ON position. > Figure: Diagram of a control board and enlarged seven-position MODE DIP switch bank. Switch positions are labeled 1 through 7, with ON at top and OFF at bottom. Arrows identify individual switches and point to the following settings. | DIP#6 | DIP#7 | Delay Time for Auto-Close | |---|---|---| | ON | ON | 15 seconds | | ON | OFF | 30 seconds | | OFF | ON | 60 seconds | | OFF* | OFF* | 120 seconds (factory preset) | **DIP#5** ON — D1 mode, constant pressure to operate gate. OFF* — B2 mode, momentary contact to operate gate. **DIP#4** ON — Push-to-open operation. OFF* — Pull-to-open operation. **DIP#3** ON — Auto-close enabled. OFF* — Auto-close disabled. **DIP#2** ON* — Buzzer warning enabled. OFF — Buzzer warning disabled (for auto-close and soft start/stop only). **DIP#1** ON* — Soft start enabled. OFF — Soft start disabled. \* Factory preset. > Figure: Control-board illustration includes readable labels “SET LIMIT,” “LEARN TRANSMITTER,” “MODES,” “STALL FORCE,” “RECEIVER,” and terminal labels including “EXIT/OPEN,” “SHADOW LOOP,” “CLOSE EDGE,” “OPEN EDGE,” “GRN,” “BLK,” and “RED.” > Figure: Black warning box: > > **IMPORTANT CONTROL BOARD SETTINGS:** > > **CONTROL BOARD DIP SWITCH #1 is factory preset in the ON position and MUST remain in the ON position. Changing this setting can damage your gate, gate opener and possibly void your warranty!** ## Page 27 # Setting the Closed Position Limit ## TURN CONTROL BOX ON Your GTO/PRO gate operator has two Limit Settings 1) **OPEN Limit setting:** (Gate in the OPEN POSITION / the limit is FACTORY SET and NOT ADJUSTABLE) The open limit setting is the fully open position. 2) **CLOSED Limit setting:** (Gate in the CLOSED POSITION) To achieve optimum closed position, you are required to complete the following FOUR STEPS: ### Step 1 Confirm that the power switch is in the ON position and the gate is in the OPEN POSITION. ### Step 2 Activate your opener by pressing the entry transmitter button. Your gate should now be moving from the fully open position toward the closed position. Prepare to STOP the gate by pressing the entry transmitter button again when the gate reaches the desired closed position. This step may be repeated until desired close position is achieved. Once the desired CLOSED position has been achieved, proceed to step 3. ### Step 3 With the gate in the desired closed position PRESS & HOLD the “SET LIMIT” button on the control board for 5 seconds. ### Step 4 Press the transmitter button and allow the gate to return to the fully open position. YOUR GATE’S CLOSED POSITION LIMIT IS NOW PROGRAMMED. > Figure: Control-board drawing. An arrow labeled “Set Limit Button” points to the button marked “SET LIMIT.” Other readable labels include “COM,” “CYCLE CLOSE,” “SAFETY,” “EXIT/OPEN,” “SHADOW LOOP,” “CLOSE EDGE,” “OPEN EDGE,” “RECEIVER,” “GRN,” “BLK,” “RED,” “MODES,” “LEARN TRANSMITTER,” “STALL FORCE,” “MIN,” “MAX,” “ON,” and “OFF.” ## TESTING YOUR CLOSED LIMIT SETTING: Press your entry transmitter and allow your gate to close. If the CLOSED position is not correct or needs to be changed, you will need to CLEAR your CLOSED LIMIT settings and follow Steps 1-4 again. ## CLEARING THE PROGRAMMED CLOSED LIMIT SETTING: If you make a mistake and set the limit at the wrong position – press your transmitter to return the gate to the fully opened position, then press and hold the "SET LIMIT" button for 10 seconds. This will clear the memory for the closed limit position. Follow Steps 1-4 again. ## Page 28 # Obstruction Sensitivity Potentiometer **IMPORTANT:** For safety reasons the obstruction setting or **Stall Force** on the GTO/PRO control board comes from the factory set at **MIN** (minimum). In many gate installations this setting will need to be adjusted to overcome the weight and size of the gates. The **Stall Force** potentiometer on the control board operates like a volume control on a radio. It controls the obstruction sensitivity (or the amount of force the opener will apply to an obstruction) before it automatically stops and reverses direction for approximately two (2) seconds. Use a small slotted screwdriver to turn the arrow in the center of the potentiometer. Adjust the sensitivity from the MINIMUM position where the gate operates without obstructing from its own weight or the wind conditions in your area. **NOTE:** You may need to increase the stall force in cold weather due to increased resistance from gate hinges. > Figure: Control-board illustration with a magnified view of the Stall Force potentiometer. The potentiometer is labeled “STALL FORCE,” with “MIN” on the left and “MAX” on the right. Curved arrows indicate adjustment from MIN toward MAX. The control board also shows labeled switches “DUAL MODES,” “MODES,” “SET LIMIT,” and “LEARN TRANSMITTER,” plus ON and OFF positions. **ALWAYS KEEP SAFETY AT THE TOP OF YOUR LIST WHEN ADJUSTING OR SERVICING YOUR AUTOMATIC GATE OPENER!** ## Page 29 # Setting Your Personal Transmitter Code All GTO/PRO transmitters are set to a standard code at the factory and are ready to operate your GTO/PRO gate operator. For your safety and security, however, we strongly recommend that you replace the factory setting with your own personal code. Follow the directions below: ## 1. Remove the Transmitter Cover On the back of the transmitter use a small phillips head screw driver to remove the two screws on the sides of the visor clip and separate the front cover from the transmitter. With the front cover removed, the battery and the DIP switches will be exposed. To set a new code, use a small screwdriver to move the switches. > Figure: Drawing of a GTO transmitter with its front cover removed. The cover bears the label “GTO.” The opened transmitter shows an LED, a battery labeled “A23S 12V ALKALINE BATTERY,” and a nine-switch DIP switch bank labeled 1 through 9. A separate enlarged DIP-switch illustration shows positions “+”, “0”, and “–”, switch numbers 1–9, and “ECE.” ## 2. Set the transmitter DIP Switches There are nine (9) transmitter DIP switches; each can be placed in three different positions (+, 0, –). **DO NOT** set all the switches in the same position, such as all +, all 0, or all –. Once the DIP switches have been set to a personal code, replace front cover. **WARNING: No other adjustments should be made inside the transmitter.** > Figure: Perspective drawing of the nine-position DIP switch bank, numbered 1 through 9, with plus, zero, and minus position markings. ## 3. “Teach” the New Code to Control Board Memory A. Press and hold transmitter button. B. Press and hold the **LEARN TRANSMITTER** button on the control board for 5 seconds. C. Release **LEARN TRANSMITTER** button. D. Release transmitter button. The new code is stored in control board memory. > Figure: Control-board drawing. An arrow labeled “Learn Transmitter Button” points to a pushbutton labeled “LEARN TRANSMITTER.” Readable board labels include: COM; CYCLE CLOSE; SAFETY; EXIT/OPEN; SHADOW LOOP; CLOSE EDGE; OPEN EDGE; RECEIVER; GRN; BLK; RED; STALL FORCE; MIN; MAX; TRANSMITTER; MODES; OFF; ON; SET; LIMIT; and DIP switch numbers 1–7. The illustrated order is: hold transmitter button, hold LEARN TRANSMITTER button for 5 seconds, release LEARN TRANSMITTER button, then release transmitter button. ## Page 30 # Installing the Receiver Use the transmitter to check the range of the receiver before permanently mounting it. Consider the following when mounting the receiver: - Standard receiver cable length is 10 feet (receivers with a longer cable are available as special order items; call the *GTO/PRO Sales Department*). NEVER splice receiver cable! - **Run the cable through PVC conduit to protect it from damage.** - DO NOT run cable through metal conduit because the receiver signal range will be decreased. - DO NOT run cable in conduit containing ac wiring. - The receiver range can vary from 50 to 100 feet depending upon weather, topography, and external interference. **NOTE: Do not mount upside down.** > Figure: Drawing of a GTO receiver mounted upright on a vertical post. A long vertical antenna extends above the receiver. A cable exits the receiver, runs down the post, and loops at its free end. A screw is shown beside the post, indicating mounting. > Figure: Boxed notice: > > **FCC Regulation** > This device complies with FCC rules Part 15. Operation is subject to the following conditions: > 1. This device may not cause harmful interference. > 2. This device must accept an interference that may cause undesired operation. > > Transmitter distance may vary due to circumstances beyond our control. **NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.** ## Page 31 # Connecting Additional Safety Devices > Figure: Boxed notice: > > Although GTO/PRO strongly recommends the use of additional safety devices, we do not endorse any specific brand names. Only use products that are certified and listed to be in compliance with any applicable UL standards (United Laboratories) and national and regional safety codes. > > Call GTO/PRO Sales at 1-800-543-4283 for information on compatible products for your specific application. The GTO/PRO SW-2500 will ONLY accept accessory devices with normally open dry contact output. ## Contact Sensors (safety edges) **If not installing a contact sensor skip to next section.** **PLEASE NOTE:** Contact sensors are not *included* with the GTO/PRO SW-2500. The GTO/PRO SW-2500 is equipped with built-in obstruction sensitivity. The opener is designed to stop and reverse the gate within 2 seconds when it comes in contact with an obstruction. However, obstruction sensitivity, although functioning properly, *may not be sensitive enough to prevent bodily injury in some circumstances.* To augment your protection against entrapment, *GTO/PRO recommends using some form of additional safety device.* When installed, contact sensors must be mounted in compliance with UL 325, Underwriters Laboratories safety standard for gate openers. Review page 5 for information about mounting requirements for safety edges ("contact sensors"). *Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate.* > Figure: Warning symbol and warning text: “Make sure the power switch to the opener is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the opener OFF.” ### Contact Sensor Input Connection: Connect one of the OPEN EDGE contact sensor wires to the **COMMON (COM)** terminal and the other to the **OPEN EDGE** terminal on the GTO/PRO SW-2500 control board. Connect one of the CLOSE EDGE contact sensor wires to the **COMMON (COM)** terminal and the other to the **CLOSE EDGE** terminal on the GTO/PRO SW-2500 control board. **Activation of a contact sensor while the gate is in motion will cause the gate to stop and reverse within two (2) seconds.** > Figure: Control-board terminal connection drawing. Two wires labeled “Wire from Contact Sensor (open safety edge)” connect to COM and OPEN EDGE terminals. Two wires labeled “Wire from Contact Sensor (close safety edge)” connect to COM and CLOSE EDGE terminals. Board labels include COM, CYCLE CLOSE, SAFETY, EXIT/OPEN, SHADOW LOOP, CLOSE EDGE, OPEN EDGE, RECEIVER, GRN, BLK, RED, STALL FORCE, MIN, and MAX. Arrows point upward from the wires to their terminal connections. ## Page 32 # Non-Contact Sensors (photo beams) **If not installing a non-contact sensor skip to next section.** **PLEASE NOTE:** Non-contact sensors are not *included* with the GTO/PRO SW-2500. The GTO/PRO SW-2500 can also accept "Safety" input from normally open "dry-contact" output devices such as photo beams connected to the SAFETY input terminal. *Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate.* > Figure: Warning symbol and warning text: “Make sure the power switch to the opener is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the opener OFF.” ### Non-Contact Sensor Connection: Connect one of the non-contact sensor dry contact output wires to the **COMMON (COM)** terminal and the other to the **SAFETY** terminal on the GTO/PRO SW-2500 control board. **This input is ONLY monitored when the gate is closing. Activating the non-contact sensor (obstructing the safety beam path) will cause the gate to reverse to the fully open position.** > Figure: Control-board terminal connection drawing. A two-wire cable labeled “Wire from Non-Contact Sensor (photo beam)” connects to COM and SAFETY terminals. Board labels include COM, CYCLE CLOSE, SAFETY, EXIT/OPEN, SHADOW LOOP, CLOSE EDGE, OPEN EDGE, RECEIVER, GRN, BLK, RED, STALL FORCE, MIN, and MAX. Arrows point upward from the wires to the COM and SAFETY terminals. # Shadow Loop **If not installing a shadow loop skip to next section.** **PLEASE NOTE:** Non-contact sensors are not *included* with the GTO/PRO SW-2500. *Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate.* > Figure: Warning symbol and warning text: “Make sure the power switch to the opener is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the opener OFF.” ### Shadow Loop Connection: Connect one of the shadow loop wires to the **COMMON (COM)** terminal and the other to the **SHADOW LOOP** terminal on the GTO/PRO SW-2500 control board. The **SHADOW LOOP** is a detector located within the moving path of the gate to prevent the gate from closing when a vehicle is in the path. > Figure: Control-board terminal connection drawing. A two-wire cable labeled “Wire from Shadow Loop” connects to COM and SHADOW LOOP terminals. Board labels include COM, CYCLE CLOSE, SAFETY, EXIT/OPEN, SHADOW LOOP, CLOSE EDGE, OPEN EDGE, RECEIVER, GRN, BLK, RED, STALL FORCE, MIN, and MAX. Arrows point upward from the wires to the COM and SHADOW LOOP terminals. ## Page 33 # Connecting Accessories **If not connecting accessories skip to next section.** The GTO/PRO SW-2500 can accept NORMALLY OPEN CONTACT accessories, such as; Push Button Entry Devices and Key Pads. *Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate.* ⚠ **Make sure the power to the opener is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the opener OFF.** ## Accessory Input Connection: Connect one of the accessory wires to the COMMON (COM) terminal and the other to the CYCLE CLOSE terminal on the GTO/PRO SW-2500 control board. **Each activation of the accessory will cause the gate to cycle as follows:** > Figure: Cycle sequence diagram with arrows: **OPEN → STOP → CLOSE → STOP**. > Figure: Control-board terminal diagram. A wire labeled “Wire from Accessory (push button, key pad, etc.)” splits to the two left terminals labeled **COM** and **COM**. Additional readable terminal labels: **CYCLE CLOSE**, **SAFETY**, **EXIT/OPEN**, **SHADOW LOOP**, **CLOSE EDGE**, **OPEN EDGE**; receiver terminals **GRN**, **BLK**, **RED**; **RECEIVER**. Dial labeled **STALL FORCE**, with **MIN** and **MAX**. ## Page 34 # Push to Open Installation ## Determining The Mounting Position of The Post Bracket Assembly ⚠ **Swinging gates shall not open into public access areas!** A "Push-to-Open" gate opens *out* from the property. A **Push-To-Open Bracket is required for this type of installation** *(see Accessory Catalog).* If you have a pull-to-open gate (gate opens *into* the property), return to page 13; step 3. In a PUSH-TO-OPEN installation, the openers are installed while the gates are in the **closed** position. ## Step 1 With the gates **closed**, adjust the post bracket assembly and the gate bracket until the opener is level. While holding the opener level, use C-clamps to temporarily keep the post bracket assembly and gate bracket in their respective positions on the fence post and gate. > Figure: Exploded “Post Bracket Assembly” drawing. Parts, top to bottom: **3/8" x 2" Bolt**, Post Bracket, **Push-To-Open Bracket (optional accessory)**, Post Bracket, **3/8" Washer**, **3/8" Lock Washer**, and **3/8" Nut**. **IMPORTANT:** While determining the mounting point for the post pivot bracket assembly, be sure that the position allows for maximum clearance between the gate and the opener in both the open and closed positions, as shown in the diagrams below. This clearance will give the opener the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area. > Figure: Side-view diagram of gate in the open position, showing opener and gate post. Labels: **Gate in the Open Position**, **Pinch Area (gray)**, and **2" minimum** clearance. > Figure: Side-view diagram of gate in the closed position, showing opener beneath gate. Labels: **Gate in the Closed Position**, **Pinch Area (gray)**, and **2" minimum** clearance. ## Step 2 After verifying that you have the best position for the post pivot bracket, insert the 5/16" x 1 3/4" bolt through the aligned holes of the post bracket and post pivot bracket and fasten it with the 5/16" washer and nut. **IMPORTANT:** If you loosened the clamp on the post bracket to achieve the optimum position, tighten it in its new position and recheck the gate bracket with the gate in the open position (move the gate bracket and re-clamp it if necessary). ## Page 35 ## Step 3 With the gate in the **fully closed position** and the opener retracted, swing the opener to the gate. Mark reference points for bolt holes on gate cross member through middle of gate bracket slots. The opener must be level. (Some vertical adjustment is possible by sliding the post bracket assembly up and down.) Drill 3/8" holes into the gate cross member as marked. Fasten gate bracket to cross member using (2) 3/8" x 3" bolts, washers, lock washers, and nuts. Attach the opener to the post bracket assembly and gate bracket using clevis pins, bushings, and hairpins clips. > Figure: Installation alignment drawing showing a **Fence Post**, **Gate Post and Gate Cross Member (In Closed Position)**, operator, post pivot bracket, and gate bracket. Dashed level lines are labeled **LEVEL**. Label and arrow state: **POST PIVOT BRACKET level with the horizontal surface of the GATE BRACKET**. ## Step 4 Make sure the control box power switch is **OFF**. Use a small screwdriver to move the **Number 4 DIP switch** from the factory setting (OFF / Pull-To-Open) to **ON for Push-To-Open**. Turn power switch **ON**. The control board is now configured to *push* the gate open. > Figure: Control-board drawing with enlarged DIP-switch inset. Switches are numbered **1 2 3 4 5 6 7**; arrows identify **ON** and **OFF** positions. Arrow identifies **DIP#4**. Text: **ON—Push-to-open operation.** **OFF—Pull-to-open operation (factory setting).** # Setting the Open Position Limit ## Step 1 Confirm that the power switch is in the ON position, and the gate is in the CLOSED POSITION. ## Step 2 Activate your opener by pressing the entry transmitter button. Your gate should now be moving from the closed position toward the open position. Prepare to STOP gate by pressing the entry transmitter button again when the gate reaches the desired open position. This step may be repeated until desired open position is achieved. Once the desired OPEN position has been achieved, proceed to Step 3. ## Page 36 ## Step 3 With the gate in the desired open position PRESS & HOLD the “SET LIMIT" button on the control board for 5 seconds. ## Step 4 Press the transmitter button and allow the gate to return to the closed position. YOUR GATE’S OPEN POSITION LIMIT IS NOW PROGRAMMED. ## TESTING YOUR OPEN LIMIT SETTING: Press your entry transmitter and allow your gate to open. If the OPEN position is not correct or need to be changed, you will need to CLEAR your OPEN LIMIT settings and follow steps one (1) to four (4) again. ## CLEARING PROGRAMMED OPEN LIMIT SETTING: If you make a mistake and set the limit at the wrong position – press your transmitter to return the gate to the fully closed position, then press and hold the "SET LIMIT" button for 10 seconds. This will clear the memory for the open limit position. Follow steps one (1) to four (4) again. > Figure: Control-board diagram with arrow identifying the **Set Limit Button**. Readable labels include: terminal blocks **COM**, **CYCLE CLOSE**, **SAFETY**, **EXIT/OPEN**, **SHADOW LOOP**, **CLOSE EDGE**, **OPEN EDGE**; receiver terminals **GRN**, **BLK**, **RED**, **RECEIVER**; **STALL FORCE** dial with **MIN** and **MAX**; **MODES** DIP switch numbered **1 2 3 4 5 6 7** with **ON** and **OFF**; buttons **LEARN TRANSMITTER** and **SET LIMIT**. ## Page 37 33 # Troubleshooting Guide If your gate opener does not function properly after it is installed, use this guide before calling the GTO/PRO Service Department. ### Audible Alarm Indications | Symptom | Diagnosis | |---|---| | 1) Gives one short beep and no operations when you press the remote. | 1) There is a power problem with the Mighty Mule 500/502, PRO-SW2500/2502, PRO-SW3000/3200 and PRO-SW4000/4200.<br><br>- The battery could have a dead cell in it.<br>- The battery could be low. Disconnect the transformer or solar panel and check the battery voltage. If the battery is fully charged, the voltage should be between 12.5 vdc to 13.5 vdc. Any voltage reading below 12vdc is low.<br>- The battery could be dead or disconnected at battery or board. The transformer or solar panel is powering the board with the charge voltage. Disconnect the transformer or solar panel to see if the board still powers up.<br>- The fuse is blown. Replace the fuse. | | 2) Gives a three second tone, 1 second of silence, and then another three second tone repeatedly. | 2) On the Mighty Mule 500/502, PRO-SW2500/2502, PRO-SW3000/3200 and PRO-SW4000/4200, the board is giving a limit switch error. Check the connections on the power cable. If this does not work, check the terminal voltages on the circuit board that is supplied to the limit switch. The voltage across the orange and green and the brown and green should be 5 vdc without the arm connected. If the board is good, the arm will need repair. | | 3) Gives a constant tone. | 3) Mighty Mule 500/502, PRO-SW2500/2502, PRO-SW3000/3200 and PRO-SW4000/4200<br><br>- The battery could be very low at about 10 vdc. Flip the power switch off and back on to see if it will clear the alarm. If the alarm is not cleared, check to make sure that there is power at the outlet. There could be a tripped breaker or GFI. The transformer could be unplugged. The transformer could be blown. If there is no charge power from the transformer, the green light will be off.<br><br>- The board has sensed an obstruction two times in a row. If the alarm clears by switching the power off and on, the board is sensing an obstruction.<br>&nbsp;&nbsp;o Something on or about the gate is causing the arm to push too hard to open or close the gate. Look for something in the path of the gate or something unlevel, out of plumb, or that is binding or pinching.<br>&nbsp;&nbsp;o This can be due to a low battery when the unit is charged with a solar panel. Test the charging circuit and the solar panel in direct sunlight.<br>&nbsp;&nbsp;o If the alarm will clear by switching the power off and on, the board is sensing an obstruction. Disconnect the arm from the gate. If it is still obstructing, increase the Stall Force. Max it out if you have to. However, do not leave the Stall Force at this setting when connected to the gate. If the arm is in the middle of its cycle, it extends a couple of inches, retracts a couple of inches, and the tube does not hit the limit switch when retracted, the rev counter in the arm is bad. | ## Page 38 34 # Diagnostic LEDs ### Status (Clear LED) 1) The Status LED blinks once whenever there is a change in any of the control inputs. This includes changes to any of the seven position DIP switches on the board, the Set Limit Button or the Learn Transmitter button is pressed, the limit switch in the arm is activated, or any of the six accessory inputs (cycle/close, safety, exit/open, etc.) are used. 2) The Status LED flashes when the board learns a new limit. 3) Use these lights to determine if the circuit board is receiving inputs from the control inputs or the accessories. ### RF (Yellow LED) 1) The RF LED flickers whenever the antenna receiver receives a radio frequency in the 318 MHz range. 2) The RF LED flickers when the remote transmitter or the wireless keypad is activated. 3) Electronic noise that produces a 318 MHz signal will cause the RF LED to flicker. An electric motor running is one example. 4) When the RF LED flickers, the receiver chip (U8) and the antenna receiver are working properly. ### AC Power (Green LED) 1) The AC Power LED stays on whenever the transformer is putting out voltage to the circuit board. If the AC Power LED is off, there is no power from the transformer. 2) The AC Power LED does not come on when the battery is charged by solar panel without the transformer or when the transformer is unplugged. ### Red LED 1) The Red LED comes on whenever the battery is fully charged. Any time power is drained from the battery to operate the gate; the light goes off until the battery is fully charged again. Under normal operations, the light will cycle on and off indicating the charging circuit is keeping the battery charged. 2) If the AC Power LED is on and: 1. ...the Red LED is on and the unit is not working. a. The fuse could be blown. The unit will give one short beep when the remote is pressed or when an accessory is used. b. The battery is not connected or there is a loose connection. Check the wires that connect to the battery and where they connect to the circuit board from the battery. The unit will give one short beep when the remote is pressed or when an accessory is used. c. The battery is no longer taking a charge. The battery could have a dead cell. Unplug the transformer and check the voltage on the battery under a load (try to operate the gate opener). If the voltage drops more than 1 vdc, the battery has a dead cell. The unit will give one short beep when the remote is pressed or when an accessory is used. 2. ...the Red LED is off. a. The battery is charging if the unit is working. The battery voltage should increase until it gets to 14.5 vdc. b. The battery may be low if the unit is not working. Unplug the battery and check the voltage. The battery should have 12.5 to 13.5 vdc. Any voltage reading below 12 vdc is a little low and could cause intermittent or no operations. ## Page 39 35 3) If the AC Power LED is off and: 1. ...the Red LED is on and the unit is not working. a. If the unit is charging with solar in adequate sunlight, the battery is not connected or there is a loose connection. Check the wires that connect to the battery and where they connect to the circuit board from the battery. The unit will give one short beep when the remote is pressed or when an accessory is used. b. The battery is no longer taking a charge. The battery could have a dead cell. Disconnect the solar panel and check the voltage on the battery under a load (try to operate the gate opener). If the voltage drops more than 1 vdc, the battery has a dead cell. The unit will give one short beep when the remote is pressed or when an accessory is used. c. The fuse could be blown if the battery is being charged by solar panel. The unit will give one short beep when the remote is pressed or when an accessory is used. 2. ...the Red LED is off. a. If the unit is working, the battery is charged by a solar panel, and there is adequate sunlight, the battery is charging. b. If the unit is not working, the battery may be low. Disconnect the battery and check to see if there is over 12 vdc on the battery. If not, charge the battery with a trickle charger at 12 vdc 2 adc for three to four hours. c. If the unit is not working, the fuse could be blown. The unit will give one short beep when the remote is pressed or when an accessory is used. d. If the unit is not working, the battery is not connected or there is a loose connection. Check the wires that connect to the battery and where they connect to the circuit board from the battery. The unit will give one short beep when the remote is pressed or when an accessory is used. # Repair Service If your GTO/PRO SW-2500 Gate Opener is not operating properly, please follow the steps below: 1. First use the procedures found in the Maintenance & Troubleshooting Guide (see page 33). 2. If you are unable to solve the problem, call the GTO/PRO Service Department at (800) 543-1236, or (850) 575-4144. Refer to the serial number (located on the control box cover) and date of purchase when calling for assistance. 3. If repair or replacement of your gate opener is necessary, the Service Department will assign a Return Goods Authorization (RGA) number to you for warranty repair. 4. Securely pack the component(s) authorized for return to the factory. Write the RGA number issued to you on the outside of the package in LARGE BOLD PRINT. Ship the package(s) freight prepaid to: GTO/PRO, 3121 Hartsfield Road, Tallahassee, Florida, USA 32303. **NOTE:** Products returned to GTO/PRO without a Return Goods Authorization (RGA) number in LARGE BOLD PRINT on the outside of the package WILL NOT be accepted. Also, items returned to GTO/PRO freight collect WILL NOT be accepted. The GTO, Inc. Technical Service Department is open Monday – Friday 8:00 A.M. – 5:00 P.M. (Eastern Time) 1-800-543-1236 • FAX (850)575-8950 e-mail: techsupport@gtoinc.com ## Page 40 36 # Column Installation Information ## IF THIS OPENER WILL BE USED WITH GATES THAT ARE MOUNTED ON MASONRY, BRICK, OR ROCK (etc.) COLUMNS: ## READ THE FOLLOWING CAREFULLY BEFORE PROCEEDING A. The simplest solution is to install the opener in a push-to-open configuration (requires Push-To-Open Bracket, see Accessory Catalog). The minimum clearance is easier to achieve and clearance is no longer a problem, since the opener will be pushing the gate away from the column instead of pulling it toward the column. It is recommended that you place a steel plate between the opener mounting brackets and masonry surface for additional strength. B. If a push-to-open installation is impossible due to traffic hazards, terrain, etc., another option is to re-hang the gate. You may hang it on a post, either in the center of the column or at the back corner, or move the gate to the back corner of the columns. C. The most difficult solution is to cut a notch in the column to accommodate the opener and power cable. This job is **NOT** for the inexperienced! > Figure: Column mount example diagram. A rectangular **Column** is shown at left, with a horizontal **Gate** extending to the right from a circular **Hinge** at the column edge. A **Pivot Bracket** is mounted above the column; a bold arrow points right toward it. Dashed dimension lines identify horizontal dimension **A** from the pivot bracket to the column edge and vertical dimension **B** from the pivot bracket level down to the gate/hinge level. Text reads: “Column Mount Example (A + B can not exceed 14 inches) Example: If A is 2" then B can not exceed 12".” A bold arrow points upward toward the **Hinge**. ## Page 41 > Figure: GTO/PRO PROFESSIONAL ACCESS SYSTEMS logo. # ACCESSORIES > Figure: Drawings of two solar panels on tubular steel supports. **Solar Panel (FM123), (FM122)** The Solar Panel is a 10 watt solar powered battery charger for use with the all GTO/PRO DC gate operator systems. Particularly suited for remote installations, each Solar Panel comes with tubular steel support, mounting clips, wire connectors, and 8 ft. of low voltage wire (see Low Voltage Wire for additional wire). The GTO/PRO® control board has clearly labeled terminal connections for easy installation of the Solar Panel. Installation in some regions of the world will require multiple solar panels for adequate charging power. **Solar Panel (FM122) is a 5 watt solar powered battery charger with all the same features as (FM123).** > Figure: Drawing of a narrow rectangular push-button control with a circular button. **Push Button Control (RB101)** Unlit doorbell button for remote entry or exit control. Wires directly to the control board and uses 16 gauge multi-stranded, dual conductor low voltage wire (sold separately). > Figure: Drawing of a pin lock: a vertical pin with round head mounted in a rectangular lock body. **Pin Lock (FM345)** The Pin Lock substitutes for the clevis pin at the front end of the GTO/PRO® 1500 gate operator. Helps prevent theft of the operator from the gate, while allowing quick release of the operator. > Figure: Drawing of a key-chain mini transmitter with key ring. **Key Chain Mini Transmitter (RB744)** The Key Chain Mini Transmitter is a miniature version of the GTO/PRO® entry transmitter and has the same adjustable code settings. 12 Volt battery included. > Figure: Drawing of a single-button entry transmitter. **Entry Transmitter (RB741)** The GTO/PRO® entry transmitter, with adjustable code settings, is standard equipment with all GTO/PRO® systems. 9 Volt battery included. > Figure: Drawing of a digital keypad mounted in a tall rounded housing. **Digital Keypad (F300)** The specially designed digital keypad can be easily installed as a wireless or wired keypad. It can be programmed to use up to fifteen different personal identification number (PIN) codes. Each code is face programmable with additional security features built in. Wired installations require 16 gauge, low voltage, multi-stranded, dual conductor, direct burial wire (sold separately). Requires 3 AA batteries (not included). > Figure: Drawing of an Exit Wand: a long tubular wand with coiled wire. **GTO/PRO 50' Exit Wand (FM139), 100' Exit Wand (FM140), 150' Exit Wand (FM141)** The GTO/PRO® Exit Wand is designed for residential and agricultural applications and is compatible with all GTO/PRO® automatic gate operator models. The wand is an electromagnetic sensor, which offers 'hands free' operation of the GTO/PRO® Gate Operators with a 12 ft. radius of detection of vehicles in motion. > Figure: Drawing of an Automatic Gate Lock Pull-to-Open assembly, including lock receiver and lock body labeled “GTO/PRO.” **Automatic Gate Lock Pull-to-Open (FM144)** A MUST for added security. Solenoid driven, with a steel housing. Unlocks and locks automatically as gates open and close. Used with GTO/PRO® DC swing gate operating systems for maximum stability and security. Comes with a keyed manual release. Recommended for gates over 8 ft. long. Ideal for animal enclosures or high wind areas. > Figure: Drawing of a wireless entry intercom/keypad with antenna and base unit. **Wireless Entry Intercom / Keypad (FM136)** Allows owner to screen guest at the gate before allowing access to the property. Keypad also allows owner to give up to 25 programmable entry codes to family, friends or approved delivery personnel. Codes can be permanent or temporary. Can be wireless or hard wired up to 1000 feet. ## Page 42 # ACCESSORIES > Figure: Drawing of a rectangular replacement battery. **Replacement Battery (RB500)** Standard 12 volt, 7.0 amp-hour, maintenance-free battery for the **GTO/PRO SW-2000, GTO/PRO SW-2500, GTO/PRO SW-3000, GTO/PRO SW-4000** gate operator systems. This is the only battery approved for use with the **GTO/PRO** gate operator systems. Life expectancy is 3-5 years. > Figure: Drawing of a coiled roll of low-voltage wire. **Low Voltage Wire (RB509)** The 16 gauge, multi-stranded, dual conductor **Low Voltage Wire** is for connecting the AC powered transformer, or the **Solar Panel** to the control board. Also used for the connection of accessories, such as locks, keypads, push buttons and other wired control devices. This specially designed wire is UV treated, PVC coated and ready for direct burial. Available in 1000' rolls or special lengths. > Figure: Drawing of a flat Push to Open Bracket with mounting holes. **Push to Open Bracket (347 IH)** Required when **GTO/PRO SW-2500** gate operator(s) must push the gate open, such as on a sloping driveway or where space prevents gate(s) from opening inward (pulled open). Order two PTO brackets for conversion of a dual swing gate installation. > Figure: Drawing of a Column Mount Lock Receiver bracket. **Column Mount Lock Receiver (433IH)** For mounting the **Automatic Gate Lock** on brick columns, walls, or for other applications with limited space between gate and post. > Figure: Drawing of a replacement transformer with two electrical prongs. **Replacement Transformer (RB570)** Standard 18 volt AC transformer for maintaining the battery included with the **GTO/PRO SW-2500** gate operator. This is the only transformer approved for use with all UL325 **GTO/PRO** gate operator systems. > Figure: Drawing of a Garage Door Receiver unit. **Garage Door Receiver (RB709)** The Garage Door Receiver allows you to use the same **GTO/PRO** entry transmitter (see Dual and Triple Transmitters) to operate your gate operator and your garage door operator. Compatible with most garage door operators. > Figure: Drawings of Dual and Triple Button Transmitters. **Dual & Triple Button Transmitters (RB742 & RB743)** The Dual (RB742) & Triple (RB743) Button Transmitters are for remote control of multiple separate gate operators, and/or gate operator(s) and garage door operator(s) (see Garage Door Receiver). 9 Volt battery included. > Figure: GTO/PRO PROFESSIONAL ACCESS SYSTEMS logo. **If you have a question about any special order item, just call 1-800-543-GATE!** The contents of all material available on this installation manual are copyrighted by GTO, Inc. (“GTO”), unless otherwise indicated. All rights are reserved by GTO, and content may not be reproduced, downloaded, disseminated, published, or transferred in any form or by any means, except with the prior, written permission of GTO, Inc. Any reprinting of GTO publications is by permission only. Copyright infringement is a violation of federal law. GTO/PRO®, GTO/PRO® are registered trademarks of GTO, Inc. and are the exclusive property of GTO, Inc. (“GTO”). All rights are reserved by GTO, Inc., and these marks may not be used, in any form without the prior, written permission of GTO, Inc.