Skip to main content
## Page 1 Copyright © 2021 Nortek Security & Control LLC PRINTER’S INSTRUCTIONS: INSTR, INSTL, FM143 - P/N: 10024428 Rev-B - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - PRINT FRONT AND BACK - SCALE: 1-1 IMPORTANT: Before you install the automatic gate lock be sure your gate is level, moves freely on its hinges, and does not bind or drag against the ground. # GTO AUTOMATIC GATE LOCK® # Installation Manual > Figure: Cover-page product photograph showing the Automatic Gate Lock and its lock receiver bracket. The lock is a black rectangular unit with a key cylinder and slotted mounting bracket; the separate black receiver bracket has mounting holes. Readable logo text above: “GTO AUTOMATIC GATE LOCK®”. **PLEASE NOTE:** Because of the various mounting applications, no mounting hardware is provided with the Automatic Gate Lock. All necessary mounting hardware can be obtained from your local hardware store; all other hardware is provided. This manual shows two examples of the most common installations, and should provide insight into most other applications. If you have any questions during installation, please call (800) 543-1236 for technical support. FM143/FM144 Installation Manual Printed in China ## Page 2 FM143/FM144 Installation Manual \[5/20/21\] 2 # Before You Begin... For the Automatic Gate Lock to work properly, the gate must close firmly against a positive stop and engage the lock catch against the lock receiver. Achieving optimal closure may require slight adjustments to the gate opener settings. Installing the lock with the Gate Opener may require adjusting limits and stall force. Refer to your individual gate opener installation manual for information on these adjustments. Set the limits so that the arm holds the gate snug against the stop in the closed position. **IMPORTANT:** You may need to spray the locking mechanism with silicone spray initially to help the latch move freely. If you are installing the lock on a Push-to-Open gate (gate opens out), the lock must be installed on the outside of the gate. Depending upon the installation, the gate post may need to be "pocketed" to accommodate the lock receiver. Contact the Nortek Control Technical Service Department at (800) 543-1236 for assistance if needed. NOTE: Positive stops are required for dual gate applications. # Parts Included: A - Lock with 20' of low voltage wire B - Lock Receiver C - Clevis Pin D - Locking Cap E - Lock Board Battery Lead Wires F - White Wire (motor lead to lock board) G - Lock Control Board (Lock PCB) &nbsp;&nbsp;&nbsp;&nbsp;(Not required for most systems) H - 2 Double Spade Tongue terminals I - 6 Nylon Cable Tie J - Wire Connector K - Lock Keys (for manual release) L - Lock Decal > Figure: Parts diagram labeled A through L. A is the lock with coiled wire, labeled dimensions 2", 5½", and 8½". B is the lock receiver, labeled dimensions 2" and 2¾". C is the clevis pin, labeled 3½" and “¼” Diameter.” D is the locking cap. E is the lock board battery lead wires. F is the white wire. G is the Lock Control Board (Lock PCB). H shows 2 double spade tongue terminals. I shows 6 nylon cable ties. J is a wire connector. K shows lock keys. L is a decal reading “MIGHTY MULE AUTOMATIC GATE LOCK.” # What else do you need? Mounting hardware is not included. Read these instructions completely and review the installation examples to determine the mounting hardware required for your application. NOTE: The Automatic Gate Lock is designed to use mounting hardware up to **5/16"** in diameter. For a more secure installation, use lock washers and lock nuts on all mounting hardware. For most **IRON** or **ALUMINUM TUBE** gates you will need: Carriage bolts, washers, and nuts for the lock and receiver. (see Illustration B, page 4) For most **CHAIN LINK** gates you will need: U-Bolts, saddles or carriage bolts, washers and nuts for the lock. Bolts, washers, and nuts for the receiver. (see Illustration C, page 4) **The installation has two parts:** 1. Mounting The Lock and Lock Receiver 2. Connecting the Control Boards Once you have the necessary mounting hardware, you can begin the installation. ## Page 3 Copyright © 2021 Nortek Security & Control LLC 3 # Installing The Gate Lock NOTE: The Automatic Gate Lock can be installed on single and dual gate systems. Use the appropriate instructions for the system you have - **SINGLE GATE** (below) or **DUAL GATES** (page 5). # Single Gate Installation Turn power switch OFF on the bottom of the control box. Disconnect gate opener by removing hairpin clip and clevis pin from the gate bracket end of the opener. Disconnecting the opener will allow the gate to swing freely during installation of the gate lock. | | | |---|---| | Step 1: | With the gate in the closed position, determine the best location for the lock and lock receiver. The lock and receiver must be level and aligned with the opener. Also, the lock should have a solid surface or cross member to provide stability (see *Illustration A* below). | | Step 2: | Clamp receiver and lock together (with receiver pin hole and lock slot aligned) against the gate post, mark their positions to drill receiver holes (see *Illustration B and C, page 4*). The receiver must be mounted with carriage bolts, not U-bolts, to allow lock to seat properly. Fasten the receiver to the gate post. | | Step 3: | Hold latch open with key to operate gate and check closed limit and lock alignment. Drop pin in receiver but don’t put the cap on. Recheck the lock’s position and alignment, then mark its position for drilling holes. | | Step 4: | Drill the holes on gate supports through the slots in the lock bracket. U-bolts and saddles can be used to mount the lock on chain link gate supports. Secure the lock to the gate. Install clevis pin and locking cap by placing clevis pin through slots in lock receiver and hammering the clevis pin into the locking cap (see *Illustration D*), secure the lock bracket and check the alignment again. | > Figure: Illustration A. Line drawing of a single picket gate and gate opener. The lock receiver is mounted at the gate post on the left, with the Automatic Gate Lock mounted on the gate and aligned horizontally with the opener arm. A dashed horizontal alignment line is labeled: “Lock and receiver must be level and aligned with opener.” Smaller drawings below show a level, properly aligned gate/lock arrangement and an angled, misaligned arrangement. ## Page 4 FM143/FM144 Installation Manual \[5/20/21\] 4 > Figure: Illustration B — “Iron or Aluminum Tube Fence and Gate Installation.” Exploded drawing of a tube fence post and tube gate. Labels identify “Clevis Pin,” “Receiver,” “Locking Cap,” “GTO Automatic Gate Lock,” and “Carriage bolts, washers, and nuts (not provided; size of fasteners depends on the gate).” Dotted lines show the receiver and lock mounting fasteners passing through the post and gate. A completed installation is shown at right. Text states: “Remember to check the alignment and mark positions before drilling holes in fence post and gate.” > Figure: Illustration C — “Chain Link Fence and Gate Installation.” Exploded drawing of a chain-link fence post and gate. Labels identify “Clevis Pin,” “Receiver,” “Locking Cap,” “Lock,” “U-bolts, saddles & nuts (not provided),” and “Added cross member to support lock from force of slamming shut.” Dotted lines show receiver bolts through the fence post and U-bolts mounting the lock to the gate cross member. Text states: “Remember to check the alignment and mark positions before drilling holes in fence post.” > Figure: Illustration D — “Locking Cap Assembly.” Step-order drawing: a clevis pin is positioned above the receiver and locking cap; below, a hammer strikes the top of the clevis pin to drive it into the locking cap. Labels: “Clevis Pin,” “Receiver,” and “Locking Cap.” ## Page 5 # Dual Gate Installation Turn power switch OFF on the bottom of the control box. Disconnect gate openers by removing hairpin clip and clevis pin from the gate bracket end of the openers. Disconnecting the openers will allow the gates to swing freely during installation of the gate lock. **NOTE:** In a DUAL GATE INSTALLATION the gate opener on the same side of the driveway as the control box is known as the PRIMARY GATE OPENER and that gate is referred to as the PRIMARY GATE. Conversely the gate opener on the other gate is referred to as the SECONDARY GATE OPENER and the gate is referred to as the SECONDARY GATE. **IMPORTANT:** To use the gate lock on a dual gate system, the gate sequencing must be set so the PRIMARY GATE opens first and closes last, and the gate lock has to be mounted on the PRIMARY GATE and the lock receiver is mounted on the SECONDARY GATE. Some Linear and Mighty Mule gate operators are preprogrammed with this functionality. The secondary gate requires a positive stop. If your gates are not sequenced in a manner that works like this, you'll have to change the sequencing on your gate opener. Follow the instructions in your gate opener installation manual for programming dual gate sequencing. | | | |---|---| | Step 1: | With the gate in the closed position, determine the best location for the lock and lock receiver. The lock and receiver must be level and aligned with the opener. Also, the lock should have a solid surface or cross member to provide stability (see illustration below). | | Step 2: | Clamp receiver and lock together (with receiver pin hole and lock slot aligned) to the gates, mark their positions to drill holes. The receiver must be mounted on the SECONDARY GATE with carriage bolts, not U-bolts, to allow lock to seat properly. | | Step 3: | Recheck the lock’s position and alignment. Hold latch open with key and operate gate. Drill the holes on gate supports through the slots in the lock bracket. U-bolts and saddles can be used to mount the lock on chain link gate supports. Secure the lock to the PRIMARY GATE. Install clevis pin and locking cap by placing clevis pin through slots in lock receiver and hammering the clevis pin into the locking cap, secure the lock bracket and check the alignment again. | > Figure: Diagram of two closed swing gates. The left gate is labeled **SECONDARY GATE** and the right gate is labeled **PRIMARY GATE**. A gate opener is shown on each gate, with the control box on the far right. The automatic lock and receiver meet at the center of the gates. Text below states: “Lock and receiver must be level and aligned with opener.” A lower detail shows the lock aligned level with the receiver; an arrow points to the latch and the text states: “Hold latch open with key to operate gate. Receiver pin hole and lock slot must line up.” A second lower detail shows the gates and lock misaligned at an angle. Copyright © 2021 Nortek Security & Control LLC ## Page 6 # Manual Lock Release The Automatic Gate Lock is keyed for manual release. Should the electronic release be disabled for any reason, simply use the key to manually open the lock. Keys are unique for security purposes and can not be replaced by Nortek Security & Control. A locksmith will be required if all copies of the keys are lost. > Figure: Drawing of the Automatic Gate Lock housing with its mounting bracket behind it. A key is inserted into the keyed manual-release cylinder on the front end of the lock. FM143/FM144 Installation Manual [5/20/21] ## Page 7 # Wiring the Automatic Gate Lock ## Wiring the lock to MM371, MM372, MM571, MM572 and TS571 Operators **NOTE:** A wire jumper is required between ‘LOCK V-’ and ‘LOCK Relay Common’. > Figure: Wiring diagram for an Automatic Gate Lock connected to a terminal strip. The lock’s negative wire connects to **LOCK V-**; the positive wire connects to the lock relay terminal labeled **NO**. A jumper wire connects **LOCK V-** to the lock relay terminal labeled **C**. Terminal-strip labels, left to right, include **AUX V+**, **AUX V-**, lock relay **C**, **NO**, **NC** with **LOCK** beneath, then **LOCK V+**, **LOCK V-**, and auxiliary relay **C**, **NO**, **NC** with **AUX** beneath. Plus and minus symbols identify the lock wires. ## Wiring the lock to MM560, MM562, Linear Pro 3000XLS and 4000XLS series operators. > Figure: Wiring diagram of a controller section labeled **CONTROL OUTPUTS**. Terminal areas are labeled **POWER INPUT**, **LOCK PWR**, and **AUX RLY**. The lock wires connect to the two **LOCK PWR** terminals, with plus and minus symbols identifying polarity. The power-input label reads **18 VOLT TRANSF. OR SOLAR PANEL**. An Automatic Gate Lock and receiver are shown below. ## Wiring the lock to MM272, HD272, MM262, MM362, MM462 Operators and Linear Pro 2000XLS series. > Figure: Wiring diagram of an Automatic Gate Lock connected to a controller board. The lock positive wire connects to **LOCK+** and the negative wire connects to **LOCK-**. Other readable board labels include **SFTY.**, **EXIT**, **CYCLE**, **EDGE SENSOR**, **COMMON**, **WHT**, **GRN**, **RED**, **BLK**, **FIRST OPR.**, **SECOND OPR.**, **PWR. SET**, **LIMIT**, **1st OPR.**, **2nd OPR.**, **STATUS**, **AUTO CLOSE**, **STALL FORCE**, **OPEN < JOG > CLOSE**, **MIN MAX OFF**, **VAR1** through **VAR6**, **K1** through **K4**, **BATT +**, **BATT –**, **14 VAC OR SOLAR**, **ON OFF**, and “REMOVE JUMPER FOR PUSH TO OPEN OPTION.” The lock wires are marked with plus and minus symbols. Copyright © 2021 Nortek Security & Control LLC ## Page 8 ## Wiring the lock to MM271 and MM260 Operator > Figure: Wiring diagram of an Automatic Gate Lock connected to a controller board. The positive lock wire connects to **LOCK+** and the negative wire connects to **LOCK -**. The board labels include **CHGR**, **COM**, **SAFETY**, **EXIT**, **CYCLE**, **EDGE**, **LOCK+**, **LOCK -**, **VAR1**, **VAR3**, **VAR4**, **VAR5**, **VAR6**, **GRN**, **M_BLK**, and **M_RED**. Plus and minus symbols identify the lock wires. ## Wiring the lock to MM360 Operators. **NOTE:** Dip switch 4 must be set to LOCK (OFF). > Figure: Wiring diagram of an MM360 controller. The Automatic Gate Lock wires connect to **AUX OUT**, marked **H** and **L**, with plus and minus symbols. Other readable controller labels include **CHARGING**, **POWER**, **18VAC/SOLAR INPUT**, **LINK**, **EXIT**, **SAFETY**, **EDGE**, **CYCLE**, **COMMON**, **RCVR**, **GRN**, **BLK**, and **RED**. A detail of the DIP switch shows positions 1 through 4; the labels are **PULL-PUSH**, **MODE1**, **MODE2**, and **LOCK/BEACON**. An arrow points from the enlarged DIP-switch detail to its location on the controller, indicating switch 4 is set to **LOCK (OFF)**. FM143/FM144 Installation Manual [5/20/21] ## Page 9 # Wiring the Lock to Gate Opener Control Boards Manufactured prior to 2006. Call Nortek Control Technical Support at (800) 543-1236 for verification if needed. | Step | Instructions | |---|---| | Step 1: | Turn control box power switch OFF and unplug the transformer or disconnect the solar panel. Remove control box cover and disconnect battery lead wires from the battery terminals before wiring the lock board to the opener control board. | | Step 2: | Connect the WHITE wire *(included)* to Terminal #1 on the lock board. Connect the RED battery lead wire *(included)* to Terminal #5 on the lock board. | | Step 3: | Attach the RED control board battery lead wire to one spade tongue on a double spade tongue connector *(included)*. Attach the BLACK control board battery lead wire to one spade tongue on the other double spade tongue connector *(included)*. | | Step 4: | Pull RED and BLACK wires from gate lock through the strain relief and into the control box. Attach BLACK wire to Terminal #3 on lock board. Attach RED wire to Terminal #4 on lock board *(see Lock Board Wiring Chart, below).* | | Step 5: | Attach RED lock board battery lead wire to the double spade tongue terminal with the RED control board lead wire. Attach the BLACK lock board battery lead wire to the double spade tongue connector with the BLACK control board Lead Wire. | | Step 6: | Connect the WHITE wire from the lock board directly to the PRIMARY OPERATOR terminal block along with the power cable wire from the opener arm. Connect the WHITE wire to the RED terminal for a Pull-to-Open installation or connect WHITE wire to the BLACK terminal for a Push-to-Open installation. | | Step 7: | Reconnect opener to gate bracket. Connect the BLACK Battery lead wire *(included)* to Terminal #2 on the lock board. *(See Lock Board Wiring Chart, below).* Connect RED wires (with double spade tongue terminal) to POSITIVE (+) battery terminal and the BLACK wires (with double spade tongue terminal) to the NEGATIVE (–) battery terminal. Plug the transformer in or rewire the solar and turn the control box power switch ON. Test opener and lock to make sure it functions properly and make adjustments if necessary. | > Figure: **Lock Board Wiring Chart.** Drawing of a lock board with a five-position terminal strip labeled, left to right, **1 2 3 4 5**. An arrow labeled **Lock Board** points to the board. The board includes a knob labeled **Time Adj**. Wire connections shown: Terminal 1, **WHITE Wire to RED for Pull-to-Open or WHITE to BLACK for Push-to-Open**; Terminal 2, **BLACK Wire To Battery Negative (–) Terminal**; Terminal 3, **BLACK Wire From Lock**; Terminal 4, **RED Wire From Lock**; Terminal 5, **RED Wire To Battery Positive (+) Terminal**. Note in figure: “* Place a dab of petroleum jelly on the terminal contacts to prevent corrosion.” **NOTE:** It is recommended that the time adjustment knob is turned all the way to the right. Copyright © 2021 Nortek Security & Control LLC ## Page 10 FM143/FM144 Installation Manual [5/20/21] # Troubleshooting If lock hangs up and does not latch properly try the following steps before contacting Technical Support: - Reset closed position limit so gate is snug against stop plate - Lubricate latch with silicone spray to help latch to operate freely - Check alignment of lock by using the key to hold the latch open while operating the gate opener If lock still does not operate properly, contact Technical Support: Technical Support: (800) 543-1236 **IMPORTANT:** For the optimum service and safety, find the ideal stall force sensing setting for your gate opener. Depending on the weight of your gate, the ideal setting will be just enough to move your gate without self-obstruction (stopping or reversing due to its own weight), yet sensitive enough to reverse and stop when it meets with an obstruction such as a car. See the Gate Opener Installation Manual for information on obstruction settings. **NOTE:** Be sure your gate moves freely on its hinges without binding or dragging. ## Page 11 Mighty Mule, GTO, and Linear are wholly owned brands of Nortek Security & Control. # Limited Warranty This product is warranted to the original consumer (“You”) by Nortek Security & Control LLC (“Nortek Control”) against defects in material and workmanship. This limited warranty only extends to You if You purchased directly from Nortek Control or through one of Nortek Control’s authorized sales partners. The warranty period commences on the date of Your purchase and survives for the respective product warranty period, as set forth in the chart below. | Model | Warranty Length | |---|---| | Gate Accessories | 12 months | Please note, you are responsible for all labor costs associated with removing, reinstalling and returning the product to Nortek Control, including the cost of shipping the product to Nortek Control. Nortek Control will, at its option, either repair or replace any product that it confirms is defective and is eligible for service under this warranty and will return the repaired or replaced product to You at Nortek Control’s cost. Replacements may be made from b-stock products. If an exact replacement is not available, Nortek Control will, at its option, select the nearest equivalent product. Nortek Control will return warranted repaired or returned replacements by UPS Ground or an equivalent service. Second day or next-day service may be available at Your expense. This warranty does not apply to damage to the product from negligence, abuse, abnormal usage, misuse, accidents, acts of god, normal wear or tear or due to failure to follow the manufacturer’s instructions, or arising from improper installation, storage or maintenance. EXCEPT FOR THE EXPRESS WARRANTIES EXPRESSLY CONTAINED IN THIS LIMITED WARRANTY, NORTEK CONTROL MAKES NO OTHER PRODUCT REPRESENTATIONS OR WARRANTIES OF ANY KIND. ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING IMPLIED WARRANTIES OF TITLE, NON-INFRINGEMENT, MERCHANTABILITY, AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. IN NO EVENT WILL NORTEK CONTROL BE RESPONSIBLE FOR INCIDENTAL, COMPENSATORY, PUNITIVE, CONSEQUENTIAL, INDIRECT, SPECIAL, OR OTHER DAMAGES. Some states do not allow the exclusion or limitation of incidental and consequential damages, so the above limitation or exclusion may not apply to You. Any warranties implied by law are limited to the time periods set forth above. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to You. This warranty gives You specific legal rights, and You may also have other rights which vary from state to state. In order to be protected by this warranty, a copy of the receipt or other valid proof of purchase must be provided; the warranty cannot be honored without proof of purchase. You must send a copy of your proof of purchase with any product that is being repaired or replaced under this warranty. In order to initiate warranty service for Your product, please call Technical Services at (800) 543-1236 for a Return Authorization Number (“RA#”) and other important details. You must obtain a RA# before returning Your product for warranty service. www.mightymule.com • www.linear-solutions.com • www.nortekcontrol.com Copyright © 2021 Nortek Security & Control LLC ## Page 12 > Figure: Three brand logos across the top: **MIGHTY MULE** with a mule illustration and the URL **www.mightymule.com**; **GTO ACCESS SYSTEMS, LLC** and the URL **www.nortekcontrol.com**; and **LINEAR** with the URL **www.linear-solutions.com**. > Figure: Nortek Control logo and contact information: **NORTEK CONTROL**; **Nortek Security & Control**; **5919 Sea Otter Place • Carlsbad, CA 92010 • USA**; **Phone: (800) 421-1587**. ©2021 Nortek Security & Control LLC. All rights reserved. Mighty Mule, GTO Access Systems and Linear are registered trademarks of Nortek Security & Control LLC. FM143/FM144 Installation Manual [5/20/21] 10024428 Rev-B