> Figure: Cover page with “Installation Manual for the” above the Linear PRO ACCESS™ logo; large outlined “3000XLS” with “NCB” at right; “SINGLE Gate Operator System” and “PROFESSIONAL INSTALLATION RECOMMENDED!” An outlined warning box includes warning-triangle icons. Bottom includes ETL Listed / Intertek logo, GTO ACCESS SYSTEMS, LLC logo, and publication information.
# SINGLE Gate Operator System
## PROFESSIONAL INSTALLATION RECOMMENDED!
## ⚠ WARNING! ⚠
This equipment is similar to other gate or door equipment and meets or exceeds Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has hazards associated with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions. Failure to follow installation and safety instructions can result in hazards developing due to improper assembly. You agree to properly install this product and that if you fail to do so GTO Access Systems, (“GTO”) shall in no event be liable for direct, indirect, incidental, special or consequential damages or loss of profits whether based in contract tort or any other legal theory during the course of the warranty or at any time thereafter. The installer and/or user agree to assume responsibility for all liability and use of this product releasing GTO Access Systems, from any and all liability. If you are not in agreement with this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this product for full replacement value.
**READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY** before attempting to install and use this automatic gate operator. This gate operator produces a high level of force. Stay clear of the unit while it is operating and exercise caution at all times.
All automatic gate operators are intended for use on *vehicular gates only.*
This product meets and exceeds the requirements of UL 325, the standard which regulates gate operator safety, by Underwriters Laboratories Inc.
For more information on the GTO ACCESS SYSTEMS full line of automatic gate operators and access controls visit our website at **www.linearproaccess.com**.
©2016 GTO Access Systems
Printed in China for GTO
R4815 06-03-16
## Page 2
# Class Rating
The GTO 3000XLS Gate Operator is intended for use with **vehicular swing gates in single family residential applications.** The operator is system certified to be in compliance with UL 325, current edition, as of publication date.
## Vehicular Gate Operator Class Categories:
**Residential Vehicular Gate Operator—Class I:** A vehicular gate operator (or system) intended for use in a home of one-to-four single family dwelling, or a garage or parking area associated therewith.
**Commercial/General Access Vehicular Gate Operator—Class II:** A vehicular gate operator (or system) intended for use in a commercial location or building such as a multifamily housing unit (five or more single family units), hotel, garages, retail store, or other building servicing the general public.
**Industrial/Limited Access Vehicular Gate Operator—Class III:** A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public.
**Restricted Access Vehicular Gate Operator—Class IV:** A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.
> Figure: Boxed conversion-reference table.
### Converting Metric Units to English Equivalents
| When You Know | Multiply By | To Find | Symbol |
|---|---:|---|---|
| centimeters | 0.3937 | inches | in. (or ") |
| meters | 3.2808 | feet | ft. (or ') |
| kilograms | 2.2046 | pounds | lb. (or #) |
### Converting English Units to Metric Equivalents
| When You Know | Multiply By | To Find | Symbol |
|---|---:|---|---|
| inches | 2.5400 | centimeters | cm |
| feet | 0.3048 | meters | m |
| pounds | 0.4535 | kilograms | kg |
### Converting Temperature
| When You Know | Multiply By | To Find | Symbol |
|---|---|---|---|
| deg. Celsius | (°C x 1.8) + 32 | deg. Fahrenheit | °F |
| deg. Fahrenheit | (°F-32) ÷ 1.8 | deg. Celsius | °C |
> Figure: Boxed “FOR YOUR RECORDS” form with blank lines for serial number, date of purchase, and place of purchase.
# FOR YOUR RECORDS
Please record the following information product serial number (located on right side of control box), be sure to keep all receipts for proof of purchase. Refer to this information when calling GTO for service or assistance with your automatic gate opener.
Serial Number: ___________________________________ Date of Purchase: ________________
Place of Purchase: ___________________________________________________________________
## Page 3
# Table of Contents
| Section | Page |
|---|---:|
| Class Rating | inside cover |
| Please Read This First | ii |
| Important Safety Instructions | iii |
| Technical Specifications | 1 |
| Before You Begin... | 2 |
| Determine Charging Option for Battery: Transformer OR Solar | 2 |
| Solar Panel and Gate Activity Chart | 2 |
| Check Direction of Gate Swing | 3 |
| Prepare the Gate | 3 |
| Gate Grounding | 3 |
| 3000XLS Parts List | 4 |
| Tools Needed | 5 |
| Materials You may Need for the Installation: | 5 |
| Installation Overview | 6 |
| Install the Operator | 6 |
| Install the Post Bracket Assembly | 6 |
| Check Clearance | 8 |
| Install Gate Bracket | 9 |
| Attach Operator | 9 |
| Install Closed Position Stop Plate | 10 |
| Mount Battery Box and Control Box | 11 |
| Connect Operator Power Cable | 13 |
| Connect the Power Input | 14 |
| Control Board Settings | 16 |
| Set the Closed Position Limit (for Pull-To-Open Applications) | 16 |
| Adjust the Stall Force Setting | 17 |
| Set Auto Close Time | 17 |
| Program Your Personal Transmitter Setting | 18 |
| DIP Switch Settings | 19 |
| Connecting Accessories | 20 |
| Wiring Accessories | 20 |
| Connecting Other Auxiliary Devices (Sirens, Lights, etc.) | 21 |
| Push-To-Open Installation | 22 |
| Setting the Open Position Limit (Push-To-Open Installations) | 23 |
| Column Installation | 24 |
| Troubleshooting Guide | 25 |
| Voltage Readings | 26 |
| Repair Service | 27 |
| Accessories | 28 |
## Page 4
ii LPA 3000XLS Instruction Manual
> Figure: Header bar reading “Please Read This First,” with the GTO ACCESS SYSTEMS, LLC logo below.
# Please Read This First
Thank you for purchasing a Linear PRO Access 3000XLS. When correctly installed and properly used, your LPA 3000XLS operator will give you many years of reliable service. Please read the following information to ensure you have the correct system for your particular needs. This manual will enable you to properly install your 3000XLS Automatic Gate Operator.
The 3000XLS operator is designed for installation on a pull-to-open single leaf gate. The gate must not exceed 16 feet in length nor weigh more than 650 pounds* (please see Technical Specifications on page 1). The 3000XLS operator can be used on vinyl, aluminum, chain link, farm tube, and wrought iron gates. **Use on solid (wood) gates is not recommended. Solid surface gates have a high resistance to the wind. If the wind is strong enough, the operator will obstruct, stop, and blow fuses.**
\*NOTE: The 3000XLS can be installed on a push-to-open gate with the addition of the push-to-open bracket ⊕[R4388].
The 3000XLS operator accommodates extra transmitters, digital keypads, solar panels, push buttons, automatic gate locks, and other access control products. **These optional accessories are noted with the ⊕ symbol.**
The 3000XLS operator features **adjustable stall force.** This safety feature makes the gate stop and reverse direction within two seconds when it comes in contact with an obstruction. The “MIN” setting means the gate will exert the minimum force on an obstruction before it stops and reverses direction.
The 3000XLS operator also has an **adjustable auto-close** feature. It can be set to remain open from 3 to 120 seconds before automatically closing. Pressing the transmitter button at any time after the gate fully opens will cause it to close immediately. “OFF” is the factory setting; meaning the gate will stay open until you press the transmitter button (or keypad, etc.) again.
Please call Linear PRO Access at (800) 543-4283 for more information about our professional line of gate operators and accessories. Our Sales Department will be glad to give you the name and phone number of a Linear PRO Access dealer near you.
## BEFORE YOU BEGIN TO INSTALL YOUR AUTOMATIC GATE OPERATOR:
Read these instructions carefully and completely to become familiar with all parts and installation steps. You must read the installation manual for detailed instructions on gate operator safety and proper use of the gate operator.
> Figure: Small wizard illustration beside the text “24/7 Troubleshooting Wizard: http://support.gtoinc.com”.
## 24/7 Troubleshooting Wizard: http://support.gtoinc.com
> Figure: Gray boxed notice with a circled plus symbol. Text explains that the symbol denotes GTO accessories.
⊕ **GTO Accessories are noted with this symbol in this Installation Manual. Information about accessories can be found on page 28 and at www.linearproaccess.com.**
## Page 5
**IMPORTANT SAFETY INSTRUCTIONS**
Because automatic gate operators produce high levels of force, consumers need to know the potential hazards associated with improperly designed, installed, and maintained automated gate operator systems. *Keep in mind that the gate operator is just one component of the total gate operating system.* Each component must work in unison to provide the consumer with convenience, security, and safety.
This manual contains various safety precautions and warnings for the consumer. Because there are many possible applications of the gate operator, the safety precautions and warnings contained in this manual cannot be completely exhaustive in nature. They do, however, provide an overview of the safe design, installation, and use of this product. **CAREFULLY READ AND FOLLOW ALL SAFETY PRECAUTIONS, WARNINGS, AND INSTALLATION INSTRUCTIONS TO ENSURE THE SAFE SYSTEM DESIGN, INSTALLATION, AND USE OF THIS PRODUCT.**
Precautions and warnings in this manual are identified with this warning symbol. The symbol identifies conditions that can result in damage to the operator or its components, serious injury, or death.
**Because automatic gate operators are only part of the total gate operating system, it is the responsibility of the installer/consumer to ensure that the total system is safe for its intended use.**
---
# How To Manually Open and Close the Gate:
⚠ **CAUTION:** The gate can be opened and closed manually when the operator is disconnected. **ONLY** disconnect the operator when the operator power switch is **OFF** and the gate is **NOT** moving.
## Disconnecting the Operator
1. Turn operator power switch (Control Box) OFF.
2. Remove hairpin clip, clevis pin, and bushing from both the front and rear mounting points.
3. Remove the operator from the mount.
⚠ **CAUTION:** Because the GTO gate operator is battery powered, disconnect the operator **ONLY** when the power switch on the control box is turned **OFF**. Unplugging the transformer does not turn power to the operator **OFF**.
**NOTE:** Substitute a Pin Lock [FM345] for the clevis pin on the front mount of the gate operator to prevent unauthorized removal of the operator from the gate.
> Figure: Exploded drawing of the operator front mount connection. A gate operator push-pull tube aligns with a **Gate Bracket**. Labels and arrows identify **Front Mount**, **Clevis Pin**, **Bushing**, and **Hairpin Clip**. The clevis pin passes through the front mount and gate bracket; the bushing and hairpin clip are shown below it in alignment.
>
> A second drawing shows the operator front mount attached to the gate bracket with a padlock/pin lock installed beneath the bracket, illustrating the optional Pin Lock [FM345].
## Page 6
**IMPORTANT SAFETY INSTRUCTIONS**
# For The Consumer
⚠ **WARNING:** To reduce the risk of injury or death:
1. **READ AND FOLLOW ALL INSTRUCTIONS.** Failure to meet the requirements set forth in the instruction manual could cause severe injury or death, for which the manufacturer cannot be held responsible.
2. When designing a system that will be entered from a highway or main thoroughfare, make sure the system is placed far enough from the road to prevent traffic congestion.
3. The gate must be installed in a location that provides adequate clearance between it and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates must not open into public access areas.
4. The gate and gate operator installation **must comply with any applicable local codes.**
## I. Before Installation
1. Verify this operator is proper for the type and size of gate, its frequency of use, and the proper class rating.
2. Make sure the gate has been properly installed and swings freely in both directions. Repair or replace all worn or damaged gate hardware prior to installation. A freely moving gate will require less force to operate and will enhance the performance of the operator and safety devices used with the system.
3. Review the operation of the system to become familiar with its safety features. Understand how to disconnect the operator for manual gate operation (page iii).
4. This gate operator is intended for vehicular gates ONLY. A separate entrance or gate must be installed for pedestrian use (page vi).
5. Always keep people and objects away from the gate and its area of travel. **NO ONE SHOULD CROSS THE PATH OF A MOVING GATE.**
6. Pay close attention to the diagram below and be aware of these areas at all times.
**Entrapment Zones for a proper Pull-To-Open installation:**
**Zone 1** – leading edge of the gate and post.
**Zone 2** – between the gate and the gate post.
**Zone 3** – the path of the gate.
**Zone 4** – the space between the gate in the open position and any object such as a wall, fence, etc.
**Zone 5** – pinch points between the operator and gate.
> Figure: Plan-view diagram of a pull-to-open swing gate installation. Labels identify **ZONE 1**, **ZONE 2**, **ZONE 3**, **ZONE 4**, **ZONE 5**, **Driveway**, and **Gate in the Open Position**. A shaded curved sector marks the swing path of the gate as Zone 3. Zone 1 is at the leading edge/post at the closed gate position. Zone 2 is between the gate and gate post near the open position. Zone 4 is the area adjacent to the open gate and a nearby boundary. Zone 5 marks pinch points between the gate operator and gate. No dimensions are shown.
## Page 7
**IMPORTANT SAFETY INSTRUCTIONS**
## II. During Installation
1. Install the gate operator on the inside of the property and fence line. **DO NOT** install an operator on the outside of the gate where the public has access to it.
2. Be careful with moving parts and avoid close proximity to areas where fingers or hands could be pinched.
3. **Devices such as contact sensors (safety edges) and non contact sensors (photo beams) provide additional protection against entrapment.**
4. If push buttons or keypads are installed, they should be within sight of the gate, yet located at least 10 feet from any moving part of the gate (see diagram below). **Never install any control device where a user will be tempted to reach through the gate to activate the gate operator.**
5. Do not activate your gate operator unless you can see it and can determine that its area of travel is clear of people, pets, or other obstructions. Watch the gate through its entire movement.
6. Secure outdoor or easily accessed gate operator controls in order to prohibit unauthorized use of the gate.
> Figure: Plan-view safety diagram of a swing gate and its **Moving Gate Area** shaded gray. The diagram labels **Driveway** and states: **NEVER INSTALL any control device within gray area**. Four arrows indicate required separation of **10'** from the moving gate area: left, right, above, and below. The gate and operator are illustrated at the right side of the moving gate area.
## III. After Installation
1. Attach the warning signs *(included)* to each side of the gate to alert the public of automatic gate operation. It is **your responsibility** to post warning signs on both sides of your gate. If any of these signs or warning decals become damaged, illegible or missing, replace them immediately. Contact GTO for free replacements.
2. The gate is automatic and could move at any time, posing a serious risk of entrapment. No one should be in contact with an activated gate when it is moving or stationary.
3. Do not attempt to drive into the gate area while the gate is moving; wait until the gate comes to a complete stop.
4. Do not attempt to “beat the gate” (drive through) while the gate is closing. This is extremely dangerous.
5. Do not allow children or pets near your gate. **Never let children operate or play with gate controls.** Keep ALL gate controls away from children and unauthorized users; store controls where children and unauthorized users do not have access to them.
6. **KEEP GATE AND GATE Operator PROPERLY MAINTAINED.** Always turn power to operator OFF before performing any maintenance. Regularly grease the gate hinges. Apply silicone spray to a soft, dry cloth and clean the push-pull tube at least once a month.
## Page 8
**IMPORTANT SAFETY INSTRUCTIONS**
7. To operate this equipment safely, YOU must know how to disconnect the operator for manual gate operation (page iii). If you have read the instructions and still do not understand how to disconnect the operator, contact the LPA Service Department.
8. Disconnect the operator **ONLY** when the power is **TURNED OFF** and the gate is **NOT** moving.
9. Make arrangements with local fire and law enforcement for emergency access.
10. Distribute and discuss copies of the **IMPORTANT SAFETY INSTRUCTIONS** section of this manual with all persons authorized to use your gate.
11. **IMPORTANT: Save these safety instructions. Make sure everyone who is using or will be around the gate and gate operator are aware of the dangers associated with automated gates. In the event you sell the property with the gate operator or sell the gate operator, provide a copy of these safety instructions to the new owner.**
Should you lose or misplace this manual, a copy can be obtained by downloading one from the Linear PRO Access web site (www.linearproaccess.com), by contacting GTO Access Systems., at 3121 Hartsfield Road, Tallahassee, Florida 32303 or by calling 1-800-543-4283 and requesting a duplicate copy. One will be provided to you free of charge.
# Required Safety Precautions for Gates
## Install Warning Signs
Warning signs alert people of automatic gate operation and are **required** when installing the GTO Gate Operator. The Warning Signs included must be installed on both sides of each gate. Furthermore, a walk-through gate must be installed for pedestrian traffic. We recommend using the **GTO Bulldog Pedestrian Gate Lock [FM145]** for controlled access.
## Entrapment Protection
GTO’s inherent obstruction settings, even when properly adjusted, **may not be sensitive enough to prevent bodily injury in some circumstances.** For this reason, safety devices such as safety edge sensors (or photoelectric sensors), which stop and reverse gate direction upon sensing an obstruction, are suggested for enhanced protection against entrapment.
> Figure: Elevation drawing of a chain-link fence installation with a **Pedestrian Gate** at left and a **Vehicular Gate** at center. Labels identify **GTO Bulldog Pedestrian Gate Lock (recommended, not included)**, **Contact Sensor (recommended, not included)** at the pedestrian-gate area, a **Warning Sign** mounted on the vehicular gate, and additional **Contact Sensor (recommended, not included)** locations on the vehicular gate. **Photo Beam (recommended, not included)** devices are shown near ground level on both sides of the gate opening. The gate operator/control box is illustrated at the right gate post.
## Page 9
LPA 3000XLS Instruction Manual vii
# IMPORTANT SAFETY INSTRUCTIONS
## Secondary Means of Protection Against Entrapment
As specified by Gate Operator Safety Standard, UL 325 (30A.1.1), automatic gate operators shall have an inherent entrapment sensing system, and shall have *provisions for, or be supplied with,* at least one independent secondary means to protect against entrapment. The 3000XLS utilizes **Type A**, an inherent (i.e., built-in) entrapment sensing system as the **primary** type of entrapment protection. Also, the 3000XLS has **provisions for** the connection of **Type B1 or B2** protection to be used as the **secondary** type of entrapment protection, if desired.
1. For gate operators utilizing a non-contact sensor (e.g., photo-electric sensor– Type B1) in accordance with UL 325 (51.8.4 [h]):
A. Refer to the sensor manufacturer’s instructions on the placement of non-contact sensors for each type of application.
B. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving.
C. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier.
2. For gate operators utilizing a contact sensor (e.g., safety edge sensor– Type B2) in accordance with UL 325 (51.8.4 [i]):
A. One or more contact sensors shall be located at the leading edge, bottom edge, and post edge, both inside and outside of a vehicular swing gate system.
B. A hard wired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage.
C. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.
You may want to consider adding photo beams to your installation. GTO Photo Beams [R4222] provide a “non contact” means of entrapment protection.
> Figure: Diagram of a vehicular swing gate with an operator/control box at the right gate post. Labels identify “Leading Edge Contact Sensor on both sides of the gate” at the gate’s leading edge, “Bottom Edge Contact Sensor on both sides of the gate” along the gate bottom, and “Post Edge Contact Sensor on both sides of the gate” at the post edge. Two “Photo Beam” units are shown at ground level, one on each side of the gate opening. The gate is labeled “Vehicular Gate.” No dimensions, part numbers, torque values, wire specifications, or step order are shown.
## ENTRAPMENT ALARM (UL 325; 30A.1.1A)
The 3000XLS Gate Operator is designed to stop and reverse within 2 seconds when the gate comes in contact with an obstruction. Additionally, these operators are equipped with an **audio entrapment alarm** which will activate if the unit obstructs **twice** while opening or closing. This alarm will sound for a period of 5 minutes, or until the operator receives an intended signal from a hard wired entry/exit source (e.g. push button control or keypad) and the gate returns to a fully open or fully closed position. Turning the power switch on the control box OFF and back ON will also deactivate the alarm. Wireless controls such as transmitters and wireless keypads will not deactivate the alarm.
## Page 10
viii LPA 3000XLS Instruction Manual
# IMPORTANT SAFETY INSTRUCTIONS
> Figure: Warning sign with an exclamation-triangle icon and a drawing of a person beside a moving gate. A left-pointing arrow appears beneath the gate. Readable sign text: “WARNING”; “Moving Gate Can Cause Injury Or Death”; “1. KEEP CLEAR! Gate may move at any time.”; “2. Do not allow children to operate gate or play in gate area.”; “3. This gate is for vehicles only. Pedestrians must use a separate entrance.” Caption: “Warning signs (2 enclosed) to be installed on each side of the gate (3–5 feet above the bottom of the gate).”
> Figure: Product identification and manual-operation instruction label. Readable text: “ETL LISTED c us”; “3000XLS SERIES DC Swing Gate Operator”; “P/N LPA-3000XLS”; “Conforms to UL STD 325”; “Certified to CSA STD C22.2 No.247”; “Maximum Gate: 650 lb. (294.8 kg); 16 ft. (4.9 m)”; “Voltage: 12 Vdc; Frequency: 0 Hz; Power: 60 W”; “Class I & II Vehicular Swing Gate Operator.”; “Serial Number: LPA3000XLS-0000000”; “TO MANUALLY OPEN AND CLOSE THE GATE:” “1. Turn control box power switch OFF.” “2. Disconnect front or rear mount from mounting bracket.” “3. Pull operator away from mounting brackets and move gate.” “Disconnect operator ONLY when the control box power switch is OFF and the gate is NOT moving.” “MMDDYY”; “GTO Access Systems, LLC - Tallahassee, Florida USA”; “9901178.” Caption: “Product identification and manual operation instruction label (1) installed on right side of control box.”
> Figure: Two labels intended for the operator housing. Left label includes “3000 PRO XLS,” “1-800-543-GATE,” “www.linearproaccess.com,” and “Linear PRO ACCESS™.” Right warning label includes an exclamation-triangle icon, “WARNING,” “MOVING GATE Can Cause Injury or Death,” and a left-pointing arrow. Smaller readable text: “1. KEEP CLEAR! Gate may move at any time. 2. Do not allow children to operate gate or play in gate area. 3. This gate is for vehicles only. Pedestrians must use separate entrance.” Caption: “Logo and warning labels (2) installed on each side of operator housing.”
## Page 11
LPA 3000XLS Instruction Manual 1
# Technical Specifications
## GTO/ACCESS SYSTEMS 3000XLS AUTOMATIC GATE OPERATOR
### DRIVE
- Low friction screw drive (linear actuator) rated for -5 ºF to +160 ºF (-21 ºC to +71 ºC). Use of GTO battery heater FM316 (Not solar compatible) is recommended in extreme cold temperatures.
- Powered by a 12 V motor with integral case hardened steel gear reducer. Motor speed reduced to 375 rpm.
- Maximum opening arc of 110º. Approximate opening time (90º): 15-20 seconds, depending on weight of gate.
### POWER
- The system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable acid battery.
- Battery charge is maintained by a 120 Vac, 18 Vac output transformer. Blade-style control board fuse is rated for 25 A.
NOTE: The transformer should not be directly connected to any battery. Do not replace fuses with higher ampere rated fuses; doing so will void your warranty and may damage your control board.
- For optional solar charging see page 2.
### CONTROL
- GTO microprocessor-based control board is set for pull-to-open gate installations. DIP switches can be adjusted to accommodate an optional kit for push-to-open gates (see Accessory Catalog).
- A circuit on the control board regulates charging. “Sleep draw” is 25 mA; “active draw” is 3 to 7 A.
- Auto-memorization of digital transmitter code.
- GTO remote-mounted RF receiver tuned to 318 MHz.
- Operator length with push-pull tube fully retracted is 40 1/4”, mounting point to mounting point, arm stroke 16” max.
- Minimum gate length is 5 ft.
- Adjustable auto-close (3 to 120 seconds), and stall force potentiometers.
- Power terminal block accommodates a transformer or solar panels (not both).
- DIP switches simplify setup of gate operator.
- Accessory terminal block fully compatible with GTO push button controls, digital keypads, loops detectors, etc.
- Control board allows connection of safety edge sensors and photoelectric sensors.
- Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing.
### OPERATIONAL CAPACITY
- The Gate Capacity Chart shows approximate cycles, per day, you can expect from the LPA 3000XLS Automatic Gate Operator when powered with a transformer. Actual cycles may vary slightly depending upon the type and condition of gate and installation.
NOTE: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LB.
> Figure: “GTO/ACCESS SYSTEMS 3000XLS Gate Capacity Chart.” Subtitle: “Estimated number of daily cycles, based on use with a transformer and one(1) 12 Volt battery.” Table axes are Gate Length and Gate Weight.
| Gate Length | 50 lb. | 100 lb. | 150 lb. | 200 lb. | 300 lb. | 400 lb. | 500 lb. | 650 lb. |
|---|---:|---:|---:|---:|---:|---:|---:|---:|
| 16 ft. | 160 | 150 | 140 | 130 | 120 | 110 | 100 | 90 |
| 14 ft. | 170 | 160 | 150 | 140 | 130 | 120 | 110 | 100 |
| 12 ft. | 180 | 170 | 160 | 150 | 140 | 130 | 120 | 110 |
| 5 – 10 ft. | 190 | 180 | 170 | 160 | 150 | 140 | 130 | 120 |
To determine the number of cycles the gate operator will perform using solar panels, please see the specifications listed on page 2.
\* An operation cycle is one full opening and closing of the gate.
These specifications are subject to change without notice.
## Page 12
2 LPA 3000XLS Instruction Manual
# Before You Begin...
## 1. Determine Charging Option for Battery: Transformer OR Solar
> Figure: Boxed warning: “NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME. It will damage the control board.”
**IMPORTANT:**
- The 3000XLS’ 12 volt battery must be charged by either connecting the transformer (included) or solar panel kit [FM123] to the control board.
- The transformer is designed for indoor use. If the transformer can be plugged only into an outside electrical outlet, a weatherproof cover/housing (available at local electrical supply stores) must be used.
- If your gate is more than 1000 ft. from an AC power source, you will need to use at least 10 watts solar charging power to charge the battery [FM123]. Refer to the Solar Panel and Gate Activity chart below.
- All low voltage wire used with the GTO Gate Operator must be 16 gauge dual conductor, stranded, direct burial wire [RB509]. Do not run more than 1000 ft. of wire.
# Solar Panel and Gate Activity Chart
> Figure: Drawing of a tilted solar panel on a support pole, alongside explanatory text: “The table and map illustrate the maximum number of gate cycles to expect per day in a particular area when using from 10 to 30 watts of solar charging power. The figures shown are for winter (minimum sunlight).” No readable dimensions are shown.
| Winter Ratings for 12 V Single Gate | Zone 1 | Zone 2 | Zone 3 |
|---|---:|---:|---:|
| 10 watts | 8 | 16 | 26 |
| 15 watts | 11 | 20 | 30 |
| 20 watts | 14 | 28 | 38 |
| 25 watts | 17 | 36 | 46 |
| 30 watts | 20 | 44 | 54 |
Accessories connected to your system will draw additional power from the battery.
NOTE: A minimum of 10 watts solar charging power is needed to charge the batteries. Adding a second battery [RB500] will improve the number of gate cycles.
- 10 Watt Solar Panel [FM123]
- 5 Watt Solar Panel [FM122]
> Figure: Map of the United States, including Alaska and Hawaii in insets, divided into solar zones. Labels identify “Zone 1” across the northern and northeastern region, “Zone 2” across a central/eastern band, and “Zone 3” across the southwest, southern Florida area, Alaska, and Hawaii. Horizontal shading bands mark zone boundaries.
## Page 13
### 2. Check Direction of Gate Swing
The 3000XLS is designed for PULL-TO-OPEN installations. PUSH-TO-OPEN installations require a Push-To-Open Bracket [R4388]. Please refer to specific Push-To-Open Installation Information on page 22.
> Figure: Two gate-swing diagrams. Left: “Pull-To-Open (arm retracts to open)” with “Your Property” below the gate and a curved arrow showing the gate swinging inward. Right: “Push-To-Open (arm extends to open)” with “Your Property” below the gate and a curved arrow showing the gate swinging outward.
### 3. Prepare the Gate
- The gate must be plumb, level, and swing freely on its hinges.
- The gate must move throughout its arc without binding or dragging on the ground.
- Wheels must NOT be attached to the gate.
- Gates over 250 lb. should have ball bearing hinges with grease fittings.
- Post must be secured in the ground with concrete (minimizes twist/flex when the operator is activated).
- Make sure there is a stable area for mounting the gate bracket (this may require the addition of a horizontal or vertical cross member).
- We recommend you position the operator near the center-line of the gate to keep the gate from twisting and flexing, and to avoid back-splash from rain.
> Figure: Chain-link gate diagram labeled A–F. Labels: “A – Level”; “B – Plumb”; “C – Free Swinging”; “D – Posts Secured in Concrete”; “E – Centerline Mounting”; “F – Good Working Hinges.” A level is shown across the top; posts are embedded in concrete.
> Figure: Two chain-link gate examples showing mounting reinforcement. Upper drawing label: “Horizontal Cross Member.” Lower drawing label: “Vertical Cross Member.”
### 4. Gate Grounding
- Shorter cable is better, 1 to 2 feet recommended.
- Bolt ring terminal at end of cable 4 - 6 inches above ground level.
R4196 Kit Includes:
1. Ground Rod Clamp
2. 6 AWG Wire (3 feet)
**NOTE:** No grounding system absolutely protects against lightning strikes. If installed correctly, a grounding system will help minimize damage to your gate opener.
> Figure: Gate grounding diagram. A cable connects a “Metal Gate Post” to an “8 Foot Ground Rod.” Enlarged detail identifies “Ground Rod Clamp” (1) and “6 AWG Wire” (2). Ground rod specification: “5/8” Copper Clad Steel (not included) - available at local homecenter and hardware stores -”. The wire runs from a ring terminal on the metal gate post to the ground rod clamp. Arrows identify the post, wire, clamp, and rod.
## Page 14
### 5. 3000XLS Parts List
> Figure: Illustrated parts list showing master operator arm, customer support card, 6-foot power cable, bracket box contents, and hardware bag contents.
| Item | Quantity / Part Number |
|---|---|
| Customer Support Card | 1 |
| Master Operator Arm | 1 — PRO3000ARMXLS |
| 6’ Power Cable | [illegible quantity] |
| **BRACKET BOX - HB301** | |
| Closed Position Stop Plate | 1 |
| Gate Bracket | 1 |
| Post Bracket | 1 |
| Post Pivot Bracket | 1 |
| **HARDWARE BAG - H301P** | |
| 8" Nylon Cable Tie | 14 |
| 3/8" x 8" Bolt | 4 |
| 3/8" x 3" Bolt | 2 |
| 1/2" x 2-3/4" Bolt | 2 |
| 3/8" x 2-1/2" Clevis Pin | 1 |
| 3/8" x 1-3/4" Clevis Pin | 1 |
| Hairpin Clip | 2 |
| 3/8" Washer | 12 |
| 3/8" Lock Washer | 6 |
| 3/8" Nut | 6 |
| 1/2" Washer | 2 |
| 1/2" Lock Nut | 2 |
| 2" Screw | 5 |
| 3/8" x 1/2" Bushing | 1 |
| 3/8" x 3/16" Bushing | 2 |
## Page 15
> Figure: Illustrated components: “GTO Transmitter (1),” “Battery (1),” “Transformer (1),” “Control Box (1),” “Receiver (1),” and “Warning Signs (2).” The warning sign reads: “WARNING”; “Moving Gate Can Cause Injury Or Death”; “1. KEEP CLEAR! Gate may move at any time.” “2. Do not allow children to operate gate or play in gate area.” “3. This gate is for vehicles only. Pedestrians must use a separate entrance.”
### 6. Tools Needed
- Power Drill
- Pliers
- Level
- Tape Measure
- Wire Strippers
- Center Punch
- Open End Wrenches: 9/16” and 3/4”
- Drill Bits: 3/8” and 1/2”
- Hacksaw or Heavy Duty Bolt Cutters
- Small (Flat Head) Screwdriver
- Phillips Screwdriver
- C-Clamps: small, medium, and large
- Adjustable Wrench
- Extra person will be helpful
> Figure: Tool illustration labeled: “Drill,” “Drill Bit,” “Pliers,” “Level,” “Pen,” “Center Punch,” “Hack Saw,” “Open End Wrenches,” “Hammer,” “Flat Head Screwdriver,” “Phillips Head Screwdriver,” “Wire Stripper,” “Small Flat Head,” “Tape Measure,” “Adjustable Wrench,” and “Clamps Small, Medium, Large.”
### 7. Materials You may Need for the Installation:
Depending on the type of gate and post, you may need some additional materials/hardware.
- Low voltage wire [RB509]. Length depends upon the distance between the transformer power supply and the control box. (Page 15)
- If the gate is more than 1000’ away from an AC power source you will need to use at least one 10 watt Solar Panel [FM123] to trickle charge the battery. (Page 2)
- PVC Conduit. (Page 6)
- The diameter of the post should be at least 6” in order to mount the post bracket. (Page 6)
- Depending upon the diameter of the post, you may need longer bolts than those provided. Bolts should be at least 1” longer than the diameter of the post. (Page 6)
- Metal plate for wooden posts. (Page 6)
- A horizontal or vertical cross member or mounting plate may be needed to mount the operator to the gate. (Page 3)
- Some types of installations require U-Bolts. (Page 10)
- Surge protection for transformer. (Page 15)
- Weatherproof cover for transformer if installed outside. (Page 15)
- For push-to-open applications you must have PTO Bracket [R4388).
## Page 16
### 8. Installation Overview
#### Pull-To-Open Gates (Gate Opens into the Property)
The diagram shown below is an example of a Pull-To-Open installation on a chain link fence and single gate. Mounting the operator on a masonry column requires special procedures; see Column Installation Information on page 24. Furthermore, if you have a Push-To-Open gate, see Push-To-Open Installation on page 22 before proceeding.
> Figure: Pull-to-open single chain-link gate installation overview. Labels identify “Receiver,” “Control Box with Battery,” “120 Volt indoor Transformer,” “(surge protector not supplied),” “Run 1000' (max.) of low voltage wire to control box from transformer (wire not included),” “PVC conduit (not included) to protect wire from lawn mowers and weed eaters,” “Fence Post Set in Concrete,” “Power Cable,” “Post Bracket Assembly,” “Single Gate Opener,” “Warning Sign,” “Gate Bracket,” “Closed Position Stop Plate,” “Horizontal Cross Member,” and “Gate Swings Evenly and Freely Hung Firmly and Plumb.” Arrows point from labels to the respective components.
# Install the Operator
## Install the Post Bracket Assembly
The post bracket is designed to work on a flat post. Posts must be at least 6” square in order to bolt the post bracket. When using bolts to mount the post bracket, the bolts must completely penetrate the post.
- The best method of attaching the post bracket to a metal post is welding.
- If your post exceeds 8”, it will be necessary to use hex head bolts longer than those supplied.
- Round wood posts (no smaller than 8” diameter) may be notched to create a flat surface for attaching the post bracket.
- Wood posts will require a metal plate (not provided) between the nuts and post to prevent the operator from pulling the bolts and washers through the wood.
- A post smaller than 6” in diameter should be made of metal instead of wood so that it will remain stable while the operator is moving the gate.
- Masonry columns will require masonry anchors/hardware (not provided).
> Figure: Exploded drawing of a post bracket assembly mounted to a square post and a round post. The round-post installation shows a metal plate behind the post, bolts passing through the post, and washers and nuts on the outside. No readable dimensions or torque specifications are shown.
## Page 17
**Step 1:**
Close the gate and place your level against the horizontal cross member. Position the level so that the top should be in the center of the cross member and overlaps the post. Scribe a line across the cross member and post. You will use this line to help determine position of post and gate brackets.
> Figure: Front view drawing of a closed decorative gate and gate post. A level is positioned horizontally across the center cross member and overlaps the post. A dashed horizontal scribe line extends across the cross member and post.
**Step 2:**
Position the post bracket on the post with the mounting holes centered over the scribe line. The post bracket should be flush with the edge of the post closest to the gate. Mark the position of post bracket holes on the post.
> Figure: Plan-style drawing showing the gate’s horizontal cross member meeting the gate post. A dashed scribe line runs through both; a post bracket with mounting holes is positioned on the gate-side edge of the post.
**Step 3:**
Drill holes through post as marked using a 3/8” drill bit. Install the post bracket using the four 3/8” x 8” hex head bolts and 3/8” flat washers, lock washers, and nuts (provided).
> Figure: Exploded drawing of a post bracket being bolted through a wood post with four long bolts, washers, lock washers, nuts, and a labeled **Metal reinforcement plate for wood post**.
**Step 4:**
Place the end of post pivot bracket with two holes inside the post bracket. (Notched end of Post Pivot Bracket should face gate, to accommodate the operator arm.) Align the back hole in the post pivot bracket with back hole in the post bracket. Insert 3/8” x 3” hex head bolt and washer through post pivot bracket and post bracket and secure with 3/8” washer, lock washer and nut.
> Figure: Exploded drawing of the post bracket and Post Pivot Bracket mounted on a post. Arrows identify: **3/8" x 3" Bolt**, **3/8" Washer** (above bracket), **Post Bracket**, **Post Pivot Bracket**, **3/8" Washer** (below bracket), **3/8" Lock Washer**, and **3/8" Nut**.
## Page 18
**Step 5:**
Position the operator rear mount between post pivot bracket. Place a 1/2” bushing above the rear mount and a 3/16” bushing under the rear mount. Align the hole in rear mount, bushings and post pivot bracket and secure with the 2 1/2” clevis pin and hair pin clip.
> Figure: Exploded drawing of the operator rear mount connected to the post pivot bracket. Labels and arrows identify **3/8” x 2-1/2” Clevis Pin**, **3/8” x 1/2” Delrin Bushing**, **3/8” x 3/16” Delrin Bushing under rear mount**, **Hairpin Clip**, and **Operator**.
**Step 6:**
Place a 3/16” bushing under the front mount and attach the gate bracket to the front mount using the 1 3/4” clevis pin and hairpin clip.
> Figure: Exploded drawing of the operator front mount and gate bracket. Labels and arrows identify **Front Mount**, **Gate Bracket**, **3/8” x 1-3/4” Clevis Pin**, **3/8” x 3/16” Delrin Bushing under front mount**, and **Hairpin Clip**.
# Check Clearance
**Step 7:**
Open the gate to the desired open position. Position the operator so that the gate bracket rests against the gate along the level scribed line. Check the clearance between the operator and the gate. The operator should only make contact with the gate at the gate bracket. There should be a minimum clearance of 2” between the widest part of the operator arm and the gate.
When you have achieved the best position for the post pivot bracket in the open position, insert the 3/8” x 3 3/4” bolt and 3/8” flat washer through the aligned holes of the post bracket and post pivot bracket to hold it in place.
Clamp the gate bracket to the gate using c-clamps or another type of clamp.
**IMPORTANT:** While determining the position of the post pivot bracket, be sure that the position allows for minimum 2“ of clearance between the gate and the operator in both the open and closed positions. This clearance will give the operator the most efficient leverage point for opening and closing the gate and, more importantly, provides the least possible pinch area.
> Figure: Drawing of the gate in the **OPEN POSITION (Arm fully retracted)**. The operator is shown between post and gate, with a shaded **Pinch Area** between operator and gate. An arrow marks **2" minimum** clearance at the widest part of the operator arm. A **Clamp** holds the gate bracket to the gate.
## Page 19
**Step 8**
Remove the clevis pin from the front mount and while supporting the gate operator, swing the gate and gate operator to the closed position. With the gate and gate operator in the closed position check the clearance and be sure that the gate operator is not binding at the post pivot bracket.
If you don’t have 2” clearance or the gate operator is binding on the post pivot bracket, remove the bolt in the post bracket and readjust the pivot bracket until you can achieve the proper clearance.
With the post pivot bracket in the optimum position for clearance and freedom of movement, replace the bolt in a post bracket adjustment hole and secure with washer, lock washer and nut. Return the operator to the open position and reattach the gate bracket. Recheck the gate operator level and clearance in the open position. Adjustment of the gate bracket will be necessary if the post bracket was moved. After verifying clearance, make sure the gate bracket is clamped securely.
> Figure: Side-view drawing of the gate in the **CLOSED POSITION**. The operator is below the gate cross member. Labels identify **2" minimum**, **Pinch Area**, **Clamp**, and **MAX 16"**. An inset exploded drawing shows the post bracket adjustment bolt, washer, lock washer, and nut.
# Install Gate Bracket
**Step 9**
Detach the front mount from the gate bracket. Check that the gate bracket holes are centered over the scribe line. Mark the gate in the center of the gate bracket holes. Remove the gate bracket and drill the 1/2” holes through the gate cross member and attach the gate bracket using the 1/2” x 2 3/4” bolts, washers and lock nuts.
> Figure: Diagram of a gate bracket beneath a labeled **LEVEL horizontal cross member**. Instruction label: **Mark cross member through middle of gate bracket slots and drill 1/2" holes**. Lower diagrams provide **FRONT VIEW** and **SIDE VIEW** for **Round Tube & Chain Link Gate** and **Square Tube Gate**. Additional front and side views show a decorative gate mounting arrangement labeled **Mounting Plate Created for Decorative Gate (required but not supplied)**.
# Attach Operator
**Step 10**
Make sure the gate is in the open position and the operator arm is fully retracted. Attach the operator to the securely bolted post bracket assembly and gate bracket using clevis pins, bushings, and hairpin clips, or optional Pin Lock [FM345]. Verify that the operator is level, bolts are tight, and adjust the post bracket assembly if necessary.
> Figure: Perspective drawing labeled **Gate In Open Position** showing an operator mounted from a **Fence Post** to an open gate. Labels identify **Level Operator** and **Clevis Pin, Bushing, and Hairpin Clip**.
## Page 20
# Install Closed Position Stop Plate
The closed position stop plate helps to stabilize the gate leaf in the closed position. To further enhance the stability and security of your gate, install the optional GTO Automatic Gate Lock [FM144]
**Step 11**
Remove hairpin, clevis pin, and 3/16” bushing from front mount and close the gate. Fasten the closed position stop plate to the end of the gate frame on the gate center-line (in line with the operator arm), but do not tighten it completely. Slide the closed position stop plate toward the post until they touch. Once you have moved the closed position stop plate to the correct position, tighten its hardware completely.
Use the appropriate hardware for your type of gate (U-bolts for tube or chain link gate; wood or lag screws for wood gates, etc.). This hardware is not provided.
**Step 12** Return gate to the open position and reattach operator to gate.
> Figure: Installation diagram with top and front views. The top view shows a gate opening arc with label **The gate must open 110° (max.)**, a **Gate Hinge**, and a **Closed Position Stop Plate** at the gate end. The front view labels **Closed Position Stop Plate mounted on metal post with U-bolts.** Lower top view labels **Gate Post** and **Fence Post**.
> Figure: Perspective drawing of a decorative gate in the closed position between posts. A callout identifies the **Closed Position Stop Plate** mounted where the gate meets the post. Label at bottom: **Gate In Closed Position**.
## Page 21
# Mount the Battery Box and Control Box
### Step 1
Remove the Control box from the Battery Box by removing four screws as shown in *Illustration A*.
> Figure: Illustration A shows the control box lifted from an open battery box. Four screws are shown with upward arrows indicating removal.
### Step 2
Mount the Battery Box using the screws (provided) or another secure mounting method as shown in *Illustration B*.
The battery/control box must be mounted at least 3 feet above the ground to protect it from rain splash, snow, etc., and at least 3 feet from an AC power source to prevent electrical interference.
> Figure: Illustration B shows the battery box mounted to a vertical surface with screws. An “UP” arrow is visible inside the box. Three mounting screws are indicated.
### Step 3
Slide the battery into position with the terminals to the right as shown in *Illustration C*.
> Figure: Illustration C shows a battery being slid into the battery box from the right, indicated by a left-pointing arrow. The battery terminals are on the right.
> Figure: Illustration D shows the control box and a close-up of its ON/OFF switch. The switch is shown in the OFF position.
# Connecting the Battery
### Step 4
Verify that the ON/OFF switch on the Control Box is in the OFF position. *Illustration D*.
Connect the BATTERY WIRE HARNESS wires to the battery --- RED wires to POSITIVE (+) battery terminal and BLACK wires to NEGATIVE (–) battery terminal.
The BATTERY WIRES from the CONTROL BOARD should extend through the KNOCK-OUT in the back of the CONTROL BOX. Plug the BATTERY HARNESS wires into the wires coming from the CONTROL BOX.
> Figure: Diagram shows the battery box and detached control box connected by battery harness wires. Labels and arrows identify “Red to Positive (+),” “Black to Negative (–),” and “Connectors for second battery.” Red and black wire connectors are shown.
LPA 3000XLS Instruction Manual 11
## Page 22
### Step 5
Tuck the excess battery leads into the battery box and reattach the CONTROL BOX to the BATTERY BOX.
> Figure: Open control box diagram shows four screws being inserted, indicated by arrows.
# Mounting the Receiver
### Step 1
Temporarily mount the receiver at this time. You will need to use the transmitter (page 18) to check the range of the receiver *before permanently mounting* it. You may have to try different locations before permanently mounting the receiver. The receiver range can vary from 50 to 100 feet depending upon weather, topography, and external interference.
**Mount the receiver:**
- Ensuring a line-of-sight between transmitter and antenna.
- At least 3 feet away from AC voltage.
- As high as possible for optimum range.
- DO NOT mount receiver upside down.
- DO NOT mount receiver on metal fence or post (this will decrease signal range). If attaching receiver to metal fence, you should mount receiver on a piece of wood attached to the fence (see illustration).
**The receiver cable:**
- Cable length is 10 ft. (receivers with longer cables are available as special order items; call the GTO Sales Department).
- NEVER splice receiver cable!
- Run the receiver cable through PVC conduit to protect it from damage.
- DO NOT run cable in conduit containing AC wiring.
> Figure: Receiver with antenna is mounted on a piece of wood attached to a fence post. A label reads “Receiver mounted on piece of wood.” The receiver cable runs downward and loops.
> Figure: Boxed FCC notice:
>
> This device complies with FCC rules Part 15. Operation is subject to the following conditions:
>
> 1. This device may not cause harmful interference.
> 2. This device must accept an interference that may cause undesired operation.
>
> Transmitter distance may vary due to circumstances beyond our control. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
12 LPA 3000XLS Instruction Manual
## Page 23
# Connect Operator Power Cable
### Step 1
Loosen sealing nut on strain relief hub at bottom of control box. Insert power cable into control box through strain relief. Thread approximately 6” of the power cable into the control box and re-tighten sealing nut until the power cable locks into place.
> Figure: Exploded strain relief drawing labeled “Strain Relief,” with components labeled “Lock Nut,” “Hub,” and “Sealing Nut.”
> Figure: Open control box drawing. An arrow points to the bottom opening labeled “Strain Relief.” The cable is labeled “Operator Power Cable.”
### Step 2
Insert the stripped power cable wires into the appropriate terminals on the MASTER OPERATOR terminal block. Insert the green wire into the GRN terminal, white wire into WHT, blue wire into BLUE, brown wire into BRN, orange wire into ORG, red wire into RED, black wire into the BLK.
Tighten the set screws against the end of the wires.
**NEVER SPLICE WIRES.**
Splicing permits corrosion and seriously degrades the wire’s ability to carry an adequate current.
> Figure: Wiring diagram labeled “Power Cable from the Master Operator Arm.” Wire terminals on the MASTER OPERATOR block are labeled GRN, WHT, BLU, BRN, ORG, RED, and BLK. Other terminal labels shown are COM, COM, CYCLE, SAFETY, EXIT, SHADOW, CLOSE EDGE, OPEN EDGE, GRN, BLK, and RED. Sections are labeled “MASTER OPERATOR,” “CONTROL INPUTS,” “GTO RCVR.,” and “RECEIVER.”
> Figure: Three wire-terminal examples: “Correct” shows wire secured under the screw; “Wrong” shows “Screwed into wire insulation”; “Wrong” shows “Exposed strands of wire.”
LPA 3000XLS Instruction Manual 13
## Page 24
# Connect the Power Input
**IMPORTANT:**
- The transformer is designed and intended for indoor use. If the transformer can only be plugged only an outside electrical outlet, a weatherproof cover/housing (available at local electrical supply stores) must be used.
- The only wire acceptable for use with GTO products is 16 gauge stranded, low voltage, direct burial wire [RB509]. This gauge enables the transformer to provide an adequate charge through the control board to the battery at distances up to 1000 ft.
- DO NOT use telephone wire or solid wire.
- NEVER SPLICE WIRES. Splicing permits corrosion and seriously degrades the wire’s ability to carry an adequate current.
- **NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME! Doing so will damage the control board.**
- If your gate is more than 1000 ft. from an AC power source, you will need to use at least 10 watts solar charging power [FM122/FM123] to charge the battery. Refer to the Solar Panels and Gate Activity Chart on page 2.
### Step 1
Make sure the control box power switch is OFF.
> Figure: Control box drawing with an arrow pointing to the ON/OFF switch. Enlarged inset shows the switch in the OFF position.
### Step 2
Select the electrical outlet into which you will plug the transformer. Measure the distance from this outlet to the control box following the path where the wire will be laid (allow for an additional 6” to be pulled into the control box).
### Step 3
Lay the low voltage wire in a trench following a path from the selected electrical outlet to the control box. Wires coming up from the ground should be run through PVC conduit to protect them from lawn mower blades, weed eaters, and grazing animals. Bury the wire in the trench.
### Step 4
Feed the low voltage wires upward through the strain relief opening on the lower left of the control box. Pull 6” to 8” of wire into the control box.
> Figure: Open control box with wires entering from below through PVC pipe. Labels identify “Power Cable from Master Arm,” “Low Voltage Wire from Transformer,” and “PVC Pipe.”
14 LPA 3000XLS Instruction Manual
## Page 25
### Step 5
Strip the ends of the low voltage wire and twist tightly. Attach these ends to the 18 VAC OR SOLAR terminals located on the POWER INPUTS terminal block. Be certain **not to let the exposed wires touch each other!**
Insert one transformer wire into an 18 VAC OR SOLAR terminal. Insert the other transformer wire into the remaining 18 VAC OR SOLAR terminal. The transformer wires can be connected to the 18 VAC OR SOLAR terminals regardless of color/polarity.
Tighten set screws against exposed end of wires.
> Figure: Control-board terminal illustration. A two-conductor low voltage wire is labeled **RED** and **BLACK** and **Low Voltage Wire from AC Transformer or Solar Panel**. The wires connect to the **18 VAC OR SOLAR** terminals in the vertically labeled **POWER INPUT** section. Adjacent labels include **CONTROL OUTPUTS**, **PWR LOCK**, **RLY**, **AUX**, **2ND OPERATOR**, and **MASTER OPERATOR**. Second-operator wire labels: **GRN, WHT, BLU, BRN, ORG, RED, BLK**. Master-operator wire labels: **WHT, BLU, BRN, ORG, RED, BLK**.
### Step 6
At the transformer, strip 1/2” of insulation from the ends of the low voltage wire. Attach wires to the transformer terminals. **Make sure the exposed wires do not touch each other.**
> Figure: Drawing of a transformer with two terminal screws. A screwdriver tightens a terminal screw while two low-voltage wires are attached.
### Step 7
Plug the transformer into the electrical outlet. (Use of a surge protector with the transformer is strongly recommended.) IMPORTANT: This is a class II indoor transformer; if using transformer outdoors be sure to enclose it in a weatherproof case.
> Figure: Drawing showing a plug-in transformer labeled **Class 2 Transformer** being plugged into a surge protector, which plugs into a wall outlet. The surge protector is labeled **SURGE PROTECTOR**.
LPA 3000XLS Instruction Manual 15
## Page 26
# Control Board Settings
## Set Closed Position Limit (for Pull-To-Open Applications)
### Step 1
Power switch is on, gate is in the **OPEN** position, operator arm fully retracted.
> Figure: Gate diagram labeled **Gate in OPEN Position**. A retracted operator arm is attached to the gate. An arrow identifies the **Control Box**. Inset shows an **ON/OFF** power switch.
### Step 2
Press the transmitter to activate operator arm. The gate will begin to **CLOSE**.
> Figure: Remote transmitter drawing and gate diagram labeled **Gate Closing**. The operator arm moves the gate; a curved arrow indicates the closing direction. The control box is labeled **Control Box**.
### Step 3
When the gate reaches the desired **CLOSED** position, press the transmitter to stop the gate.
> Figure: Remote transmitter drawing and gate diagram labeled **Gate Closed**. The operator arm is extended horizontally. The control box is labeled **Control Box**.
### Step 4
With the gate at the correct position, program the closed limit setting by pressing and holding LEARN MAST LIMIT.
> Figure: Control-board button detail showing buttons and labels **LEARN MAST LIMIT**, **LEARN 2ND LIMIT**, **S3**, **S2**, and **S4**. An arrow identifies the **Learn Master Limit Button**.
### Step 5
Press the transmitter again to allow the gate to return to the fully **OPEN** position.
> Figure: Remote transmitter drawing and gate diagram labeled **Gate in OPEN Position**. A curved arrow indicates gate movement toward open. The control box is labeled **Control Box**.
The gate closed position is now programmed. If you make a mistake and set the limit at the wrong position: press your transmitter to return the gate to the fully opened position, then press and hold the LEARN MAST LIMIT button for 5 seconds. This will clear the memory for the closed limit position. Repeat Steps 1-5.
16 LPA 3000XLS Instruction Manual
## Page 27
# Adjust the Stall Force Setting
The Stall Force potentiometer on the control board controls the obstruction sensitivity (or the amount of force the operator will apply to an obstruction for two (2) seconds before it automatically stops and reverses direction).
**IMPORTANT:** For safety reasons the stall force setting will need to be adjusted for your particular application.
The Stall Force potentiometer on the control board operates like a volume control on a radio. Use a small flat blade screwdriver to adjust the potentiometer. Adjust the stall force from the MIN position until the gate operates smoothly without obstructing from its own weight or wind conditions.
NOTE: you may need to increase the stall force in cold temperatures due to increased resistance from gate hinges.
> Figure: Enlarged **STALL FORCE** potentiometer dial with curved adjustment arrows and positions **MIN** and **MAX**. An arrow points to the stall-force dial on the control board. Board labels visible include **AUTO CLOSE TIME**, **OFF**, **120**, **SOFT START OFF**, **WARNING OFF**, **OPEN PULL**, **2ND OPEN DLY.**, **MODE1 OFF**, **MODE2 OFF**, and DIP-switch labels **1, 2, 3, 4**, **ON**, **DIP**, **PUSH**, **SIMULT.**
# Set Auto Close Time
The Auto-Close Time potentiometer controls the Auto-Close feature, and determines how long the gate will remain open (at the fully open position) before it begins to close. The settings for this feature are OFF, or from 3 to 120 seconds.
Adjust the Auto-Close potentiometer by using a small flat blade screwdriver.
> Figure: Control-board illustration with an enlarged **AUTO CLOSE TIME** potentiometer. The dial has curved adjustment arrows and is labeled **OFF** and **120**. An arrow identifies **Auto Close Time Potentiometer**. The adjacent dial is labeled **STALL FORCE**, with **MIN** and **MAX**. Additional readable board labels: **STATUS**, **LEARN RMT**, **LEARN MAST LIMIT**, **LEARN 2ND LIMIT**, **S3**, **S2**, **SOFT START OFF**, **WARNING OFF**, **OPEN PULL**, **2ND OPEN DLY.**, **MODE1 OFF**, **MODE2 OFF**, **ON**, **DIP**, **PUSH**, **SIMULT.**
LPA 3000XLS Instruction Manual 17
## Page 28
# Program Your Personal Transmitter Setting
All GTO transmitters are set to a standard code at the factory and are ready to operate your GTO gate operator. For your safety and security, we **strongly recommend** that you replace the factory setting with your own personal setting. Follow the directions below:
NOTE: If you have multiple transmitters, you should adjust all of them at this time. [RB741/RB742/RB743].
### Step 1
Use a small phillips head screw driver to remove the transmitter cover.
> Figure: Exploded drawing of a transmitter. The cover, transmitter circuit board, screws, battery, LED, and DIP-switch bank are shown. The battery label reads **A23S 12V ALKALINE BATTERY**. The circuit board LED is labeled **LED**.
### Step 2
Set the transmitter DIP switches using a small screwdriver. There are nine (9) switches; each can be placed in three different positions (+, 0, –). **DO NOT** set all the switches in the same position, such as all +, all 0, or all –. Once the DIP switches have been reset, replace and close the access cover.
WARNING: No other adjustments should be made inside the transmitter.
> Figure: Nine-position transmitter DIP-switch diagram. Switches are numbered **1 2 3 4 5 6 7 8 9**; positions are labeled **+**, **0**, and **–**. The switch bank is labeled **ECE**.
### Step 3
Program the new setting into the control board:
A. Press and hold transmitter button.
B. Press and hold the LEARN RMT (Learn Remote) button on the control board until the alarm sounds.
C. Release transmitter button. The new code is stored in control board memory.
D. Release the LEARN RMT (Learn Remote) button.
NOTE: If you have purchased additional transmitters, program the settings for all at this time.
> Figure: Control-board detail. An arrow identifies the **Learn Remote Button** at **LEARN RMT**. Other readable labels include **STATUS**, **LEARN MAST LIMIT**, **LEARN 2ND LIMIT**, **S3**, **S2**, **S4**, **AUTO CLOSE TIME**, **STALL FORCE**, **OFF**, **120**, **MIN**, **MAX**, **ON**, **DIP**, **PUSH**, and **SIMULT.**
### Step 4
**AT THIS POINT YOU SHOULD TEST RECEIVER RANGE BEFORE PERMANENTLY INSTALLING IT.**
> Figure: Wizard mascot illustration beside text: **The Troubleshooting Wizard has detailed information this and other Installations.**
**24/7 Troubleshooting Wizard: http://support.gtoinc.com**
18 LPA 3000XLS Instruction Manual
## Page 29
# DIP Switch Settings
## DIP Switches
### DIP Switch Settings (MODES)
**DIP Switch #1: Soft Start/Stop**
ON– Soft start enabled (factory preset).
OFF– Soft start disabled.
The Soft Start/Stop feature slowly starts the gate as it begins to open and slows the gate as it comes to the closed position. This saves wear and tear on the gate and gate operator system.
**DIP Switch #2: Warning Buzzer**
ON– Buzzer warning enabled (factory preset).
OFF– Buzzer warning disabled.
The Warning Buzzer alerts you when the gate operator is beginning to either open or close the gate. It sounds for the first 2 seconds in each direction. It also sounds a warning when the gate obstructs two times in one cycle. Switching this to OFF only disables the open and close warning not the obstruction warning.
**DIP Switch #3: Push/Pull-To-Open**
ON: Push-To-Open.
OFF: Pull-To-Open (factory preset).
If your gate opens into the property the DIP Switch is set to the OFF position (factory setting). If your gate opens out from the property the DIP Switch must be set to the ON position. NOTE: if you have a Push-to-Open gate application you will need a Push-To-Open bracket (see Push-To-Open Instructions on page 22).
**DIP Switch #4: Dual Operation**
ON– Second opens simultaneously with master.
OFF– Second opens after master (factory preset).
Note: Not applicable for single gate operator.
> Figure: Controller-board diagram showing a 4-position DIP switch, numbered 1–4, with ON direction marked. Arrows connect each switch to the descriptions above. Switch legend: 1—SOFT START: OFF / ON; 2—WARNING: OFF / ON; 3—OPEN: PULL / PUSH; 4—2ND OPEN DLY. / SIMULT.; MODE1: OFF / ON; MODE2: OFF / ON. Board labels include AUTO CLOSE TIME, STALL FORCE, OFF, 120 MIN, MAX, STATUS, LEARN RMT (S3), LEARN MAST LIMIT (S2), LEARN 2ND LIMIT (S4), and DIP.
## Page 30
# Connecting Accessories
## Input Connections
- All control inputs are dry-contact, normally open, inputs. DO NOT apply external voltage sources to these inputs.
- All inputs are connected with respect to COMMON terminal.
- The status LED will blink once when its corresponding input is activated.
**1 COM:** Circuit common (reference for all logic input)
- Two (2) terminals to provide extra common connection point.
**2 CYCLE/CLOSE:** (Typically for use with push button or hard-wired keypad)
- Each activation at this input will cycle the operation as follows:
OPEN–STOP–CLOSE–STOP–OPEN
**3 SAFETY:** (Typically for use with photo beam device, loop detector or other non-contact sensors)
- Activation of this input while the gate is closing will cause the gate to stop and return to the opened position.
- Activation of this input while the gate is opening has no effect (gate will continue to open).
- Activation of this input while gate is idle will prevent gate from closing.
**4 EXIT/OPEN:** (Typically for use with exit loop or wand)
- Activation of this input will open the gate if it’s not already at the open position
- Activation of this input while at open limit will restart the auto close time (if enabled).
- Activation of this input while gate at the fully open position will prevent gate from closing.
**5 SHADOW LOOP:** (Typically for use with loop detector)
- This input is only monitored when the gate is at the fully open position. At any other position, activation of this input has no effect on gate operation.
- Activation of this input while gate at the fully open position will prevent gate from closing.
**6 CLOSE EDGE:** (Typically for use with safety edge device)
- Activation of this input while the gate is closing will cause the gate to stop and reverse direction for approximately 2 seconds.
- Activation of this input while the gate is opening has no effect (gate will continue to open).
- Activation of this input while gate is idle will prevent gate from closing.
**7 OPEN EDGE:** (Typically for use with safety edge device)
- Activation of this input while the gate is opening will cause the gate to stop and reverse direction for approximately 2 seconds.
- Activation of this input while the gate is closing has no effect (gate will continue to close).
- Activation of this input while gate is idle will prevent gate from opening.
> Figure: Controller-board terminal diagram. Numbered arrows identify: 1—two COM terminals; 2—CYCLE; 3—SAFETY; 4—EXIT; 5—SHADOW; 6—CLOSE EDGE; 7—OPEN EDGE. Other readable labels: CONTROL INPUTS, RECEIVER, GTO RCVR., GRN, BLK, RED, and ALM.
## Page 31
# Wiring Accessories
> Figure: Wiring diagram for accessories connected to a controller board. Board labels include POWER INPUT, “GTO 18 VOLT TRANSF. OR SOLAR PANEL,” CONTROL OUTPUTS, LOCK PWR, AUX RLY, 2ND OPERATOR, MASTER OPERATOR, CONTROL INPUTS, COM, CYCLE, SAFETY, EXIT, SHADOW, CLOSE EDGE, OPEN EDGE, RECEIVER, GTO RCVR., GRN, BLK, RED, and ALM. Wire-color labels between operators: BLU, BRN, ORG, RED, BLK; repeated for 2ND OPERATOR and MASTER OPERATOR.
>
> Accessory connections shown: Automatic Gate Lock (FM144 & FM142) connects to LOCK PWR terminals. Push Button Control (RB101) connects wires numbered 1 and 2 to COM and CYCLE. Digital Keypad (F310) connects wires numbered 1 and 2 to COM and CYCLE. Photo Beams (R4222) connect wires numbered 3 and 1 to SAFETY and COM. Vehicle Sensor (FM139) connects wires numbered 4 and 1 to EXIT and COM; text states “Refer to Vehicle Sensor manual for additional connections.” Edge Sensor connects wire 1 to COM and, according to application, wire 6 to CLOSE EDGE and/or wire 7 to OPEN EDGE. Note: “There may be additional connection options for applications that are not illustrated here. Refer to accessory manuals for details.”
## Connecting Other Auxiliary Devices (Sirens, Lights, etc.)
- These 2 terminals are normally open “dry-contact” (no voltage) relay output.
- Relay is closed when the gate is in motion; Relay is open when the gate is not in motion.
- These 2 terminals maximum rating is 24Vdc, 1 Amp.
> Figure: Two-terminal auxiliary relay block labeled AUX RLY.
## Page 32
# Push-To-Open Installation Information
**Swinging gates shall not open into public access areas!**
A “Push-to-Open” gate opens out from the property (operator arm extends to open the gate). A Push-To-Open installation requires the purchase of a Push-To-Open Bracket [R4388].
**In a Push-To-Open installation the operator is installed while the gate is in the CLOSED POSITION.**
## Install the Operator
Follow directions for installing the 3000XLS beginning on page 7. *The Push-To-Open installation differs from the Pull-To-Open installation in the following ways:*
1. In a Push-To-Open installation, the arm fully extends to open the gate, and it fully retracts to close the gate. (C)
2. You will install the operator while the gate is in the **CLOSED POSITION** (arm fully retracted). (A)
3. You must use the Push-to-Open Post Pivot Bracket [R4388] in the Post Bracket assembly. (B)
4. IMPORTANT: While determining the mounting point for the post pivot bracket assembly be sure that the position allows for 2” clearance between the gate and the operator in both the open and closed positions (see diagram below). This clearance will give the operator the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area. (C)
> Figure: Diagram A, “Gate In Closed Position.” A gate is shown attached to a fence post with an operator arm fully retracted. Labels: Level Operator, Fence Post, and Clevis Pin, Bushing, and Hairpin Clip.
> Figure: Exploded assembly diagram B for the Push-To-Open Post Pivot Bracket [R4388]. Assembly order shown from top: 3/8" x 3" Bolt, 3/8" Washer, Post Bracket, 3/8" Washer, 3/8" Lock Washer, and 3/8" Nut. The bracket is labeled “Push-To-Open Post Pivot Bracket [R4388].”
> Figure: Diagram C showing gate/operator clearances in open and closed positions. In the open position, the gate is vertical and the operator arm is extended; a “Pinch Area” is marked and maximum dimension is “MAX 16".” In the closed position, the gate is horizontal and the operator arm is retracted; “Pinch Area” is marked. Both positions specify “2" minimum” clearance. Clamp labels appear at the gate mounting locations.
> Figure: Wizard illustration beside note: “*The Troubleshooting Wizard has detailed information on Push-To-Open installations.”
## Page 33
# Set Control Board for Push-To-Open
Make sure the control box power switch is OFF. Use a small screwdriver to move the Number 3 DIP switch from the factory setting (OFF / Pull-To-Open) to ON for Push-To-Open. Turn power switch ON. The control board is now configured to push the gate open.
> Figure: Control board illustration with a magnified DIP switch. DIP switches numbered 1, 2, 3, 4; switch 3 is indicated by an arrow labeled “DIP#3.” An ON/OFF direction indicator appears beside the switch. Labels: “ON: Push-to-open operation.” “OFF: Pull-to-open operation (factory setting).”
# Setting the Open Position Limit (Push-To-Open Installations)
**Step 1**
Power switch is on, gate is in the **CLOSED** position, operator arm fully retracted.
> Figure: Gate diagram labeled “Gate in Closed Position,” showing a retracted operator arm and “Control Box.” Small drawing of control-box power switch labeled “ON/OFF.”
**Step 2**
Press the transmitter to activate operator arm. The gate will begin to **OPEN**.
> Figure: Gate-opening diagram showing operator arm extending and a curved motion path. A large arrow indicates gate movement. Labels: “Gate Opening” and “Control Box.” Drawing of a transmitter is included.
**Step 3**
When the gate reaches the desired **OPEN** position, press the transmitter to stop the gate.
> Figure: Gate diagram labeled “Gate Opened,” with the gate at its open position and the operator arm extended. “Control Box” is labeled. Drawing of a transmitter is included.
**Step 4**
With the master gate at the correct position, program the open limit setting by pressing and holding **LEARN MAST LIMIT**.
> Figure: Detail of control-board buttons. Labels include “S3,” “LEARN MAST LIMIT,” “S2,” “LEARN 2ND LIMIT,” and “S4.” An arrow points to the LEARN MAST LIMIT button and is labeled “Learn Master Limit Button.”
**Step 5**
Press the transmitter again to allow the gate to return to the fully **CLOSED** position.
Gate is now programmed
> Figure: Gate diagram labeled “Gate in Closed Position,” with a retracted operator arm and “Control Box.” Text within diagram: “Gate open position is now programmed.” Drawing of a transmitter is included.
The gate closed position is now programmed. If you make a mistake and set the limit at the wrong position: press your transmitter to return the gate to the fully opened position, then press and hold the LEARN MAST LIMIT button for 5 seconds. This will clear the memory for the closed limit position. Repeat Steps 1-5.
## Page 34
# Column Installation
If this operator will be used with gates that are mounted on masonry, brick, or rock (etc.) columns, read the following carefully before proceeding
A. The simplest solution is to install the operator in a push-to-open configuration. The minimum clearance is easier to achieve and clearance is no longer a problem, since the operator will be pushing the gate away from the column instead of pulling it toward the column. It is recommended that you place a steel plate between the operator mounting brackets and masonry surface for additional strength.
B. If a push-to-open installation is impossible due to traffic hazards, terrain, etc., another option is to re-hang the gate. You may hang it on a post, either in the center of the column or at the back corner, or move the gate to the back corner of the column.
C. The most difficult solution is to cut a notch in the column to accommodate the operator and power cable. This job is NOT for the inexperienced!*
> Figure: Column-mount example diagram. A rectangular “Column” supports a horizontal “Gate” at a circular “Hinge,” indicated by an arrow. A “Pivot Bracket” below the column is indicated by an arrow. Dashed dimension lines mark horizontal dimension “A” between the pivot-bracket location and the hinge alignment, and vertical dimension “B” from the gate/hinge level to the pivot-bracket level. Text: “Column Mount Example (A + B can not exceed 16 inches) Example: If A is 7” then B cannot exceed 9”.”
> Figure: Small wizard illustration beside note: “*The Troubleshooting Wizard has detailed information on column mounting.”
## Page 35
# Troubleshooting Guide
If your gate operator does not function properly after it is installed, use this guide before calling the GTO Service Department.
# Generation 3 Audible Feedback
| SYMPTOM | DIAGNOSIS | CHECK: |
|---|---|---|
| 1 short beep upon power up | Circuit Board Powered Up & Ready | • Normal Operation |
| 1 short beep upon activation | Blown Fuse<br><br>Low or Bad Battery<br><br>Loose Battery Connection | • Fuse<br>• Battery Under Load<br>• Battery Harness Connections |
| Continuous Uninterrupted Alarm | Circuit Board Senses an Obstruction | • Path of Gate<br>• Gate for Level and Plumb<br>• Stall Force Adjustment<br>• Disconnect Safety Devices<br>• Rev Counter |
| 1 beep with 10 seconds off | Low Battery Condition | • Fuses<br>• Battery Harness Connections<br>• Battery Under Load |
| 1 beep then 2 beeps | Master Motor Terminals Shorted | • Connections to Master Inputs<br>• Master Arm Power Cable<br>• Motor<br>• Circuit Board |
| 1 beep with 2 seconds off | Master Arm Limit Switch Error | • Connections to Master Inputs<br>• Master Arm Power Cable<br>• [illegible] |
| 3 beeps with 2 seconds off | Master Arm Rev Counter Error | • Connections to Master Inputs<br>• Master Arm Power Cable<br>• Rev Counter |
## Page 36
# Generation 3 Visual Feedback
| SYMPTOM | DIAGNOSIS | CHECK: |
|---|---|---|
| Status (clear) 1 blink | Cycle Terminal Shorted | • Disconnect the push button, keypad, intercom keypad, or any other accessory wired to this terminal.<br>• Try the remote. If the remote works, then the problem is the accessory. |
| Status (clear) 2 blinks | Safety Terminal Shorted | • Disconnect the loop detector, photo beam, or any other accessory wired to this terminal.<br>• Try the remote. If the remote works, the problem is the accessory. |
| Status (clear) 3 blinks | Exit Terminal Shorted | • Disconnect exit wand, loop detector, photo beam, or any other accessory wired to this terminal.<br>• Try remote. If the remote works, the problem is the accessory. |
| Status (clear) 4 blinks | Shadow Terminal Shorted | • Disconnect the loop detector, photo beam, or any other accessory wired to this terminal.<br>• Try remote. If the remote works, the problem is the accessory. |
| Status (clear) 5 blinks | Close Edge Terminal Shorted | • Disconnect the edge sensor, photo beam, or any other accessory wired to this terminal.<br>• Try the remote. If the remote works, the problem is the accessory. |
| Status (clear) 6 blinks | Open Edge Terminal Shorted | • Disconnect edge sensor, photo beam, or any other accessory wired to this terminal.<br>• Try the remote. If the remote works, the problem is the accessory. |
| RF (yellow) Flickers | Receiving 318 MHz RF | • Normal operation when remote or wireless keypad is used. |
| RF (yellow) OFF | No 318 MHz RF Received | • Battery in Remote<br>• Program Remote<br>• Antenna Receiver Connections<br>• Antenna Receiver |
| Power (green) ON | AC or Solar Power Present | • Normal Operation |
# VOLTAGE READINGS
| Item | Reading |
|---|---|
| 18 Vac Transformer | 18.0 to 22.0 Vac |
| 10 W Solar panel (single) | 18.0 to 22.0 Vdc |
| In FULL SUN — measure voltage with the Solar Panel Disconnected. | |
| 12 V, 7 amp hour Battery<br>or Two 12V, 7 amp hour Batteries if using solar power | 12.5 to 13.5 Vdc |
| Measure voltage at battery terminals with battery disconnected | |
| Charging circuit | 12.0 to 14.8 Vdc |
| Measure voltage at battery terminals with battery connected | |
## Page 37
# Repair Service
If your LPA 3000XLS Gate Operator is not operating properly, please follow the steps below:
1. First use the procedures found in the Troubleshooting Guide (see page 25).
2. Use the 24/7 Troubleshooting Wizard at http://support.gtoinc.com.
3. If you are unable to solve the problem, call the LPA Service Department at (800) 543-1236. Refer to the serial number (located on the right side of the control box) and date of purchase when calling for assistance.
4. If repair or replacement of your gate operator is necessary, the Service Department will assign a Return Goods Authorization (RGA) number to you.
5. Once you have received your RGA# you are required to send in your original equipment for repair. Please refer to Manufactures’ Limited Warranty for complete details. Securely pack the component(s) authorized for return to the factory. Include a copy of your sales receipt for the purchase of the product(s). Write the RGA number issued to you on the outside of the package in LARGE BOLD PRINT.
Ship the package(s) freight prepaid to: GTO, 3121 Hartsfield Road, Tallahassee, Florida, USA 32303.
**NOTE: Products returned to GTO without a Return Goods Authorization (RGA) number in LARGE BOLD PRINT on the outside of the package WILL NOT be accepted. Also, items returned to GTO freight collect WILL NOT be accepted.**
## LPA Technical Service
**8:00am–7:00pm • Monday–Friday (EST)**
> Figure: GTO Access Systems, LLC logo. A small wizard illustration appears beside the troubleshooting-wizard contact line.
3121 Hartsfield Road • Tallahassee, Florida, USA 32303
800-543-4283 • Fax (850) 575-8912
Web site www.linearproaccess.com
24/7 Troubleshooting Wizard: http://support.gtoinc.com
## Page 38
# Accessories for 3000XLS
Please visit www.linearproaccess.com for photos and detailed descriptions of LPA Accessories. Or call 1-800-543-4283.
## POWERING ACCESSORIES
> Figure: Illustrations of a coiled low-voltage wire, a solar panel on a mounting post, and a rectangular battery.
**Low Voltage Wire [RB509]**
The 16 gauge, stranded, dual conductor low voltage Wire is for connecting the AC powered transformer, solar panel or wired accessories to the system’s control board. This specially designed wire is UV treated, PVC coated, and ready for direct burial.
**Solar Panel Kits [FM122/FM123]**
If your gate operator is more than 1000 ft. away from an AC power outlet, you can choose to maintain the battery charge with the GTO Solar Panel Kit.
- 10 Watt Solar Panel Charging Kit [FM123]
- 5 Watt Solar Panel Charging Kit [FM122]
**Additional/Replacement Battery [RB500]**
For additional battery power or replacement.
## “FROM VEHICLE” ENTRY AND EXIT ACCESSORIES
> Figure: Illustrations of remote transmitters, a universal antenna receiver, and a digital keypad. The keypad buttons are labeled 1–9 and 0, with letter groupings ABC, DEF, GHI, JKL, MNO, PRS, TUV, and WXY.
**Transmitters [RB741/RB742/RB743]**
Purchase an additional transmitter for each vehicle in your family. The Two-Button Transmitter can be programmed to operate both your gate operator and a garage door opener using the Universal Receiver. Or it can be programmed to open two gate operator systems.
- Single Button Transmitter [RB741]
- Dual Button Transmitter [RB742]
- Three Button Transmitter [RB743]
**Universal Receiver [RB709U-NB]**
The Universal Antenna Receiver gives you the ability to use one remote to activate your gate operator and your garage door opener. Connects to any brand garage door opener. Up to 100 ft. range.
**Digital Keypad [F310]**
Allow friends access to your property using an identification code that you provide. Program up to 25 entry codes for added security. Powered by three “AA” batteries (not included).
## Page 39
> Figure: Illustrations of a goose neck pedestal and a residential wireless entry intercom system with indoor base unit.
**Residential Wireless Entry Intercom [F3100MBC]**
Designed for added security to your automated gate with the ability to “speak to” and “screen” visitors safely from inside your home. Ideal for securing gate entrances while providing controlled access.
**Goose neck Pedestal [F100/F110]**
Designed to mount digital keypads, wireless intercom systems, and other access control devices for your gate automation system.
## “HANDS FREE” ENTRY & EXIT ACCESSORIES
> Figure: Illustrations of a wired driveway vehicle sensor with coiled cable, and a wireless vehicle sensor with antenna, sensor/transmitter, and receiver.
**Driveway Vehicle Sensor [FM139]**
Automatically activates gate operator “Hands-Free” when a vehicle exits the property. Electromagnetic sensor detects vehicles in motion.
- 50 ft. [FM139]
- 100 ft. [FM140]
- 150 ft. [FM141]
- 250 ft. [FM141-250]
**Wireless Vehicle Sensor [R4500]**
Automatically activates gate operator “Hands-Free” when a vehicle exits the property. 100 ft. range between transmitter and receiver. Easy installation.
## LOCKING & SECURITY ACCESSORIES
> Figure: Illustrations of an Automatic Gate Lock and its receiver bracket, a Bulldog Pedestrian Gate Lock with keypad and receiver bracket, and a Wireless Driveway Alarm sensor and base station. Readable product labels include “AUTOMATIC GATE LOCK” and “Bulldog.”
**Automatic Gate Lock [FM144/FM142]**
The #1 Accessory For Swing Gate Operators! Designed for added security in conjunction with GTO Automatic Gate Operators. The gate lock unlocks and locks automatically when the gate opens and closes. The perfect solution for high wind conditions.
**Bulldog Pedestrian Gate Lock [FM145]**
Designed to mount on horizontal swing “walk through” wood, chain link, and metal pedestrian gates opening in or out. Ideal for securing pools, condominiums, schools and any pedestrian gate.
**Wireless Driveway Alarm [R4450].**
This device alerts you of vehicles entering your driveway (with or without an automated gate). The indoor base station signals you with a door chime when a vehicle passes the driveway sensor.
## Page 40
## ADDITIONAL ACCESSORIES
> Figure: Illustrations of two photo beams, a pin lock, an unlit push-button control, a replacement transformer, and a gate grounding kit with cable and connectors.
**Photo Beams [R4222]**
Primary “through beam” photo beam device. Provides “non-contact” entrapment protection.
**Pin Lock [FM345]**
Use as a substitute for the clevis pin at the front mount of the 3000XLS to prevent theft of the operator.
- Pin Lock 10-pack: ten Pin Locks keyed alike [FM345KA].
**Push Button Control [RB101]**
Wire this unlit push button directly to your gate operator for simple open/close/stop operation from up to 1000 ft. away. Use 16 gauge low-voltage wire.
**Replacement Transformer [RB570]**
Standard 18 volt, 2200 mA AC transformer included with the 3000XLS to maintain battery charge.
**Gate Grounding Kit [R4196]**
The purpose of the grounding kit is to REDUCE THE RISK of damage to electronic equipment from lightning strikes. There is no protection or grounding system that can completely eliminate this risk.
## HARDWARE ACCESSORIES
> Figure: Illustrations of a Push To Open Bracket and a Column Mount Lock Receiver.
**Push To Open Bracket [R4388]**
Required when the 3000XLS must push a gate open (arm extends to open), such as away from a sloping driveway or where space prevents gate from opening into the property (pull to open). Order two brackets for a dual swing gate installation.
**Column Mount Lock Receiver [433IH]**
For use with the Automatic Gate Lock or Bulldog Pedestrian Gate Lock when mounting on brick columns or applications with limited space.