PRO-SW2000XLS installation manual (pin lock on the front mount)
## Page 1
Installation Manual for the
> Figure: Linear PRO ACCESS™ logo.
2000XLS
SINGLE Gate Operator System
PROFESSIONAL INSTALLATION RECOMMENDED!
> Figure: Boxed warning with two triangular exclamation-mark icons.
**WARNING!**
This equipment is similar to other gate or door equipment and meets or exceeds Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has hazards associated with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions. Failure to follow installation and safety instructions can result in hazards developing due to improper assembly. You agree to properly install this product and that if you fail to do so GTO Access Systems, LLC, (“GTO”) shall in no event be liable for direct, indirect, incidental, special or consequential damages or loss of profits whether based in contract tort or any other legal theory during the course of the warranty or at any time thereafter. The installer and/or user agree to assume responsibility for all liability and use of this product releasing GTO Access Systems, LLC, from any and all liability. If you are not in agreement with this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this product for full replacement value.
**READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY** before attempting to install and use this automatic gate operator. This gate operator produces a high level of force. Stay clear of the unit while it is operating and exercise caution at all times.
All automatic gate operators are intended for use on *vehicular gates only*.
> Figure: ETL Listed / Intertek certification mark with “c”, “us”, and “CM” labels.
This product meets and exceeds the requirements of UL 325, the standard which regulates gate operator safety, by Underwriters Laboratories Inc.
> Figure: GTO ACCESS SYSTEMS, LLC logo.
For more information on the GTO/ACCESS SYSTEMS full line of automatic gate operators and access controls visit our website at **www.linearproaccess.com**.
©2015 GTO Access Systems, LLC Printed in China for GTO Access Systems, LLC. R4717 06-03-16
## Page 2
# Class Rating
The 2000XLS Gate Operator is intended for use with **vehicular swing gates in single family residential applications.** The operator is system certified to be in compliance with UL 325, current edition, as of publication date.
## Vehicular Gate Operator Class Categories:
**Residential Vehicular Gate Operator—Class I:** A vehicular gate operator (or system) intended for use in a home of one-to-four single family dwelling, or a garage or parking area associated therewith.
**Commercial/General Access Vehicular Gate Operator—Class II:** A vehicular gate operator (or system) intended for use in a commercial location or building such as a multifamily housing unit (five or more single family units), hotel, garages, retail store, or other building servicing the general public.
**Industrial/Limited Access Vehicular Gate Operator—Class III:** A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public.
**Restricted Access Vehicular Gate Operator—Class IV:** A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.
> Figure: Box containing metric/English conversion tables.
### Converting Metric Units to English Equivalents
| When You Know | Multiply By | To Find | Symbol |
|---|---:|---|---|
| centimeters | 0.3937 | inches | in. (or ") |
| meters | 3.2808 | feet | ft. (or ') |
| kilograms | 2.2046 | pounds | lb. (or #) |
### Converting English Units to Metric Equivalents
| When You Know | Multiply By | To Find | Symbol |
|---|---:|---|---|
| inches | 2.5400 | centimeters | cm |
| feet | 0.3048 | meters | m |
| pounds | 0.4535 | kilograms | kg |
### Converting Temperature
| When You Know | Multiply By | To Find | Symbol |
|---|---|---|---|
| deg. Celsius | (°C x 1.8) + 32 | deg. Fahrenheit | °F |
| deg. Fahrenheit | (°F-32) ÷ 1.8 | deg. Celsius | °C |
> Figure: Bordered “FOR YOUR RECORDS” form with blanks for serial number, date of purchase, and place of purchase.
## FOR YOUR RECORDS
Please record the following information product serial number (located on right side of control box), be sure to **keep all receipts for proof of purchase.** Refer to this information when calling GTO for service or assistance with your automatic gate opener.
Serial Number: ____________________________________ Date of Purchase: __________________
Place of Purchase: ____________________________________________________________________
## Page 3
# Table of Contents
| | |
|---|---:|
| Class Rating | inside cover |
| Please Read This First | ii |
| Important Safety Instructions | iii |
| Technical Specifications | 1 |
| Before You Begin | 2 |
| Determine Charging Option for Battery: Transformer OR Solar | 2 |
| Solar Panel and Gate Activity Chart | 2 |
| Check Direction of Gate Swing | 3 |
| Prepare the Gate | 3 |
| Gate Grounding | 3 |
| 2000XLS Parts List | 4 |
| Tools Needed | 5 |
| Materials You may Need for the Installation: | 5 |
| Installation Overview | 6 |
| Install the Operator | 8 |
| Install the Post Bracket Assembly | 8 |
| Check Clearance | 9 |
| Install Gate Bracket | 10 |
| Attach Operator Arm | 10 |
| Installation of the Closed Position Stop Plate | 11 |
| Mount the Battery Box / Control Box | 12 |
| Connect Operator Power Cable | 14 |
| Connect the Transformer | 14 |
| Control Board Settings | 16 |
| Set the Closed Position Limit (for Pull-To-Open Installations) | 16 |
| Adjust the Stall Force Setting | 17 |
| Set Auto Close Time | 17 |
| Personal Transmitter Setting | 18 |
| Push-To-Open Installation Information | 19 |
| Setting the Open Position Limit (Push-To-Open Installations) | 20 |
| Solar Panel Instructions | 21 |
| Connecting Accessories | 22 |
| Wiring Accessories | 22 |
| Connecting Other Auxiliary Devices | 23 |
| Column Installation | 24 |
| Troubleshooting Guide | 25 |
| Voltage Readings | 26 |
| Repair Service | 27 |
| Accessories | 28 |
## Page 4
# Please Read This First
> Figure: GTO ACCESS SYSTEMS, LLC logo.
Thank you for purchasing the Linear Access 2000XLS. When correctly installed and properly used, your 2000XLS operator will give you many years of reliable service. Please read the following information to ensure you have the correct system for your particular needs. This manual will enable you to properly install your 2000XLS Automatic Gate Operator.
The 2000XLS operator is designed for installation on a pull-to-open single leaf gate. Each leaf must not exceed 16 feet in length nor weigh more than 500 pounds* (please see Technical Specifications on page 1). The 2000XLS operator can be used on vinyl, aluminum, chain link, farm tube, and wrought iron gates. **Use on solid (wood) gates is not recommended. Solid surface gates have a high resistance to the wind. If the wind is strong enough, the operator will obstruct, stop, and blow fuses.**
The 2000XLS can be installed on a push-to-open gate with the addition of the push-to-open bracket [3471H].
The 2000XLS operator accommodates extra transmitters, digital keypads, solar panels, push buttons, automatic gate locks, and other access control products. These optional accessories are noted with the ⊕ symbol.
The 2000XLS operator features **adjustable stall force.** This safety feature makes the gate stop and reverse direction within two seconds when it comes in contact with an obstruction. The “MIN” setting means the gate will exert the minimum force on an obstruction before it stops and reverses direction.
The 2000XLS operator also has an **adjustable auto-close** feature. It can be set to remain open from 3 to 120 seconds before automatically closing. Pressing the transmitter button at any time after the gate fully opens will cause it to close immediately. “OFF” is the factory setting; meaning the gate will stay open until you press the transmitter button (or keypad, etc.) again.
Please call Linear PRO Access at (800) 543-4283 for more information about our professional line of gate operators and accessories. Our Sales Department will be glad to give you the name and phone number of a Linear PRO Access dealer near you.
## BEFORE YOU BEGIN TO INSTALL YOUR AUTOMATIC GATE OPERATOR:
Read these instructions carefully and completely to become familiar with all parts and installation steps. You must read the installation manual for detailed instructions on gate operator safety and proper use of the gate operator.
> Figure: Wizard illustration beside the troubleshooting notice.
## 24/7 Troubleshooting Wizard: http://support.gtoinc.com
> Figure: Box with a circled plus symbol. Text: “GTO Accessories are noted with this symbol in this Installation Manual. Information about accessories can be found on page 28 and at www.linearproaccess.com.”
ii LPA 2000XLS Instruction Manual
## Page 5
# IMPORTANT SAFETY INSTRUCTIONS
Because automatic gate operators can produce high levels of force, consumers need to know the potential hazards associated with improperly designed, installed, and maintained automated gate operator systems. *Keep in mind that the gate operator is just one component of the total gate operating system.* Each component must work in unison to provide the consumer with convenience, security, and safety.
This manual contains various safety precautions and warnings for the consumer. Because there are many possible applications of the gate operator, the safety precautions and warnings contained in this manual cannot be completely exhaustive in nature. They do, however, provide an overview of the safe design, installation, and use of this product. **CAREFULLY READ AND FOLLOW ALL SAFETY PRECAUTIONS, WARNINGS, AND INSTALLATION INSTRUCTIONS TO ENSURE THE SAFE SYSTEM DESIGN, INSTALLATION, AND USE OF THIS PRODUCT.**
Precautions and warnings in this manual are identified with this warning symbol. The symbol identifies conditions that can result in damage to the operator or its components, serious injury, or death.
**Because the automatic gate operators are only part of the total gate operating system, it is the responsibility of the installer/consumer to ensure that the total system is safe for its intended use.**
## How To Manually Open and Close the Gate:
**CAUTION:** The gate can be opened and closed manually when the operator is disconnected. **ONLY** disconnect the operator when the operator power switch is **OFF** and the gate is **NOT** moving.
### Disconnecting the Operator
1. Turn operator power switch (Control Box) OFF.
2. Remove hairpin clip, clevis pin, and bushing from both the front and rear mounting points.
3. Remove the operator from the mount.
> Figure: Exploded drawing of the front mount connection. Arrows label the operator’s **Front Mount**, **Clevis Pin**, **Gate Bracket**, **Bushing**, and **Hairpin Clip**. The clevis pin is shown above the aligned front mount and gate bracket; the bushing and hairpin clip are shown below.
**CAUTION:** Because the Linear PRO Access gate operator is battery powered, disconnect the operator **ONLY** when the power switch on the control box is turned OFF. Unplugging the transformer does not turn power to the operator OFF.
NOTE: Substitute a Pin Lock [FM345] for the clevis pin on the front mount of the gate operator to prevent unauthorized removal of the operator from the gate.
> Figure: Drawing of the front mount and gate bracket secured with a pin lock in place of the clevis pin.
LPA 2000XLS Instruction Manual iii
## Page 6
# IMPORTANT SAFETY INSTRUCTIONS
## For The Consumer
**WARNING:** To reduce the risk of injury or death:
1. **READ AND FOLLOW ALL INSTRUCTIONS.** Failure to meet the requirements set forth in the instruction manual could cause severe injury or death, for which the manufacturer cannot be held responsible.
2. When designing a system that will be entered from a highway or main thoroughfare, make sure the system is placed far enough from the road to prevent traffic congestion.
3. The gate must be installed in a location that provides adequate clearance between it and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates must not open into public access areas.
4. The gate and gate operator installation **must comply with any applicable local codes.**
### I. Before Installation
1. Verify this operator is proper for the type and size of gate, its frequency of use, and the proper class rating.
2. Make sure the gate has been properly installed and swings freely in both directions. Repair or replace all worn or damaged gate hardware prior to installation. A freely moving gate will require less force to operate and will enhance the performance of the operator and safety devices used with the system.
3. Review the operation of the system to become familiar with its safety features. Understand how to disconnect the operator for manual gate operation (page iii).
4. This gate operator is intended for vehicular gates ONLY. A separate entrance or gate must be installed for pedestrian use (page vi).
5. Always keep people and objects away from the gate and its area of travel. **NO ONE SHOULD CROSS THE PATH OF A MOVING GATE.**
6. Pay close attention to the diagram below and be aware of these areas at all times.
> Figure: Plan-view diagram of entrapment zones for a pull-to-open swinging gate installation. Shaded swing path is labeled **ZONE 3**. Circular areas at the gate’s leading edge/post and gate/post are labeled **ZONE 1** and **ZONE 2**. The area beside the gate in its open position is labeled **ZONE 4**. A circular pinch-point area around the operator and gate is labeled **ZONE 5**. Additional labels: **Driveway** and **Gate in the Open Position**.
**Entrapment Zones for a proper Pull-To-Open installation:**
- **Zone 1** – leading edge of the gate and post.
- **Zone 2** – between the gate and the gate post.
- **Zone 3** – the path of the gate.
- **Zone 4** – the space between the gate in the open position and any object such as a wall, fence, etc.
- **Zone 5** – pinch points between the operator and gate.
iv LPA 2000XLS Instruction Manual
## Page 7
# IMPORTANT SAFETY INSTRUCTIONS
### II. During Installation
1. Install the gate operator on the inside of the property and fence line. **DO NOT** install an operator on the outside of the gate where the public has access to it.
2. Be careful with moving parts and avoid close proximity to areas where fingers or hands could be pinched.
3. **Devices such as contact sensors (safety edges) and non contact sensors (photo beams) provide additional protection against entrapment.**
4. If push buttons or keypads are installed, they should be within sight of the gate, yet located at least 10 feet from any moving part of the gate (see diagram below). **Never install any control device where a user will be tempted to reach through the gate to activate the gate operator.**
5. Do not activate your gate operator unless you can see it and can determine that its area of travel is clear of people, pets, or other obstructions. Watch the gate through its entire movement.
6. Secure outdoor or easily accessed gate operator controls in order to prohibit unauthorized use of the gate.
> Figure: Plan-view gate diagram showing a gray prohibited area around the moving gate. Arrows marked **10'** extend from the moving-gate area to the top, left, right, and bottom boundaries. Labels: **Moving Gate Area**, **Driveway**, and **NEVER INSTALL any control device within gray area**.
### III. After Installation
1. Attach the warning signs *(included)* to each side of the gate to alert the public of automatic gate operation. It is *your responsibility* to post warning signs on both sides of your gate. If any of these signs or warning decals become damaged, illegible or missing, replace them immediately. Contact GTO for free replacements.
2. The gate is automatic and could move at any time, posing a serious risk of entrapment. No one should be in contact with an activated gate when it is moving or stationary.
3. Do not attempt to drive into the gate area while the gate is moving; wait until the gate comes to a complete stop.
4. Do not attempt to “beat the gate” (drive through) while the gate is closing. This is extremely dangerous.
5. Do not allow children or pets near your gate. **Never let children operate or play with gate controls.** Keep ALL gate controls away from children and unauthorized users; store controls where children and unauthorized users do not have access to them.
6. **KEEP GATE AND GATE OPERATOR PROPERLY MAINTAINED.** Always turn power to operator OFF before performing any maintenance. Regularly grease the gate hinges. Apply silicone spray to a soft, dry cloth and clean the push-pull tube at least once a month.
LPA 2000XLS Instruction Manual v
## Page 8
# IMPORTANT SAFETY INSTRUCTIONS
7. To operate this equipment safely, YOU must know how to disconnect the operator for manual gate operation (page iii). If you have read the instructions and still do not understand how to disconnect the operator, contact the Linear PRO Access Service Department.
8. Disconnect the operator **ONLY** when the power is **TURNED OFF** and the gate is **NOT** moving.
9. Make arrangements with local fire and law enforcement for emergency access.
10. Distribute and discuss copies of the **IMPORTANT SAFETY INSTRUCTIONS** section of this manual with all persons authorized to use your gate.
11. **IMPORTANT: Save these safety instructions. Make sure everyone who is using or will be around the gate and gate operator are aware of the dangers associated with automated gates. In the event you sell the property with the gate operator or sell the gate operator, provide a copy of these safety instructions to the new owner.**
Should you lose or misplace this manual, a copy can be obtained by downloading one from the Linear PRO Access web site (www.linearproaccess.com), by contacting GTO Access Systems, LLC., at 3121 Hartsfield Road, Tallahassee, Florida 32303 or by calling 1-800-543-4283 and requesting a duplicate copy. One will be provided to you free of charge.
# Required Safety Precautions for Gates
## Install Warning Signs
Warning signs alert people of automatic gate operation and are **required** when installing the GTO Gate Operator. The Warning Signs included must be installed on both sides of each gate. Furthermore, a walk-through gate must be installed for pedestrian traffic. We recommend using the **GTO Bulldog Pedestrian Gate Lock** [FM145] for controlled access.
## Entrapment Protection
The operator’s inherent obstruction settings, even when properly adjusted, **may not be sensitive enough to prevent bodily injury in some circumstances.** For this reason, safety devices such as safety edge sensors (or photoelectric sensors), which stop and reverse gate direction upon sensing an obstruction, are suggested for enhanced protection against entrapment.
> Figure: Elevation drawing of a fenced gate installation. A smaller **Pedestrian Gate** is at left, with a **GTO Bulldog Pedestrian Gate Lock (recommended, not included)** at its top. A larger **Vehicular Gate** is at right with a **Warning Sign** mounted on it. Labels identify a **Contact Sensor (recommended, not included)** at the pedestrian-gate area and contact sensors along the vehicular gate’s lower edge and closing edge. **Photo Beam (recommended, not included)** units are shown near the ground on both sides of the vehicular gate.
vi LPA 2000XLS Instruction Manual
## Page 9
# IMPORTANT SAFETY INSTRUCTIONS
## Secondary Means of Protection Against Entrapment
As specified by Gate Operator Safety Standard, UL 325 (30A.1.1), automatic gate operators shall have an inherent entrapment sensing system, and shall have provisions for, or be supplied with, at least one independent secondary means to protect against entrapment. The 2000XLS utilizes Type A, an inherent (i.e., built-in) entrapment sensing system as the primary type of entrapment protection. Also, the 2000XLS has provisions for the connection of Type B1 or B2 protection to be used as the secondary type of entrapment protection, if desired.
1. For gate operators utilizing a non-contact sensor (e.g., photo-electric sensor– Type B1) in accordance with UL 325 (51.8.4 [h]):
A. Refer to the sensor manufacturer’s instructions on the placement of non-contact sensors for each type of application.
B. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving.
C. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier.
2. For gate operators utilizing a contact sensor (e.g., safety edge sensor– Type B2) in accordance with UL 325 (51.8.4 [i]):
A. One or more contact sensors shall be located at the leading edge, bottom edge, and post edge, both inside and outside of a vehicular swing gate system.
B. A hard wired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage.
C. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.
You may want to consider adding photo beams to your installation. GTO Photo Beams [R4222] provide a “non contact” means of entrapment protection.
> Figure: Diagram of a vehicular swing gate with safety devices. Labels and arrows identify: “Leading Edge Contact Sensor on both sides of the gate”; “Bottom Edge Contact Sensor on both sides of the gate”; “Post Edge Contact Sensor on both sides of the gate”; two “Photo Beam” units, one on each side of the gate; and “Vehicular Gate.”
## ENTRAPMENT ALARM (UL 325; 30A.1.1A)
The 2000XLS Gate Operator is designed to stop and reverse within 2 seconds when the gate comes in contact with an obstruction. Additionally, these operators are equipped with an audio entrapment alarm which will activate if the unit obstructs twice while opening or closing. This alarm will sound for a period of 5 minutes, or until the operator receives an intended signal from a hard wired entry/exit source (e.g. push button control or keypad) and the gate returns to a fully open or fully closed position. Turning the power switch on the control box OFF and back ON will also deactivate the alarm. Wireless controls such as transmitters and wireless keypads will not deactivate the alarm.
LPA 2000XLS Instruction Manual vii
## Page 10
# IMPORTANT SAFETY INSTRUCTIONS
> Figure: Warning sign label. Orange header with warning triangle and “WARNING.” Drawing shows a person near a moving gate, with a left-pointing arrow. Readable text: “Moving Gate Can Cause Injury Or Death”; “1. KEEP CLEAR! Gate may move at any time.”; “2. Do not allow children to operate gate or play in gate area.”; “3. This gate is for vehicles only. Pedestrians must use a separate entrance.”
Warning signs (2 enclosed) to be installed on each side of the gate (3–5 feet above the bottom of the gate).
> Figure: Product identification and manual operation instruction label. Readable text: “2000XLS SERIES DC Swing Gate Operator”; “P/N LPA-2000XLS”; “Conforms to UL STD 325”; “Maximum Gate: 500 lb. (226.7 kg); 16 ft. (4.9 m)”; “Voltage: 12 Vdc; Frequency: 0 Hz; Power: 30 W”; “Class I & II Vehicular Swing Gate Operator.” Intertek logo, “9901178.” “Serial Number: LPA2000XLS-0000000.” “TO MANUALLY OPEN AND CLOSE THE GATE:” Steps: “1. Turn control box power switch OFF.” “2. Disconnect front or rear mount from mounting bracket.” “3. Pull operator away from mounting brackets and move gate.” “Disconnect operator ONLY when the control box power switch is OFF and the gate is NOT moving.” “MMDDYY”; “GTO Access Systems, LLC - Tallahassee, Florida USA.”
Product identification and manual operation instruction label (1) installed on right hand side of control box.
> Figure: Logo and warning labels for operator housing. Left section reads “2000 PRO XLS,” “1-800-543-GATE,” “www.linearproaccess.com,” and “Linear PRO ACCESS™.” Right section is a warning label with a warning triangle, “WARNING,” a gate/person drawing and left-pointing arrow, and: “MOVING GATE Can Cause Injury or Death”; “1. KEEP CLEAR! Gate may move at any time.”; “2. Do not allow children to operate gate or play in gate area.”; “3. This gate is for vehicles only. Pedestrians must use a separate entrance.”
Logo and warning labels (2) installed on each side of operator housing.
viii LPA 2000XLS Instruction Manual
## Page 11
# Technical Specifications
## LINEAR PRO ACCESS 2000XLS AUTOMATIC GATE OPERATOR
### DRIVE
- Low friction screw drive (linear actuator) rated for -5˚F to +160˚F (-21˚C to +71˚C). Use of LPA battery heater FM316 (Not solar compatible) is recommended in extreme cold temperatures
- Powered by a 12 V motor with integral case hardened steel gear reducer. Motor speed reduced to 395 rpm.
- Maximum opening arc of 110˚. Approximate opening time (90˚): 15-19 seconds, depending on weight of gate.
### POWER
- The system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable acid battery.
- Battery charge is maintained by a 120 Vac, 14 Vac output transformer.
**NOTE:** The transformer should not be directly connected to any battery. Do not replace fuses with higher ampere rated fuses; doing so will void your warranty and may damage your control board.
- One (1) blade style fuse is rated for 15 A.
- For optional solar charging see page 2.
### CONTROL
- LPA microprocessor-based control board is set for pull-to-open gate installations. Jumper can be removed to accommodate an optional kit for push-to-open gates (see Accessory Catalog).
- A circuit on the control board regulates charging. “Sleep draw” is 15 mA; “active draw” is 2 to 5 A.
- Auto-memorization of digital transmitter code.
- LPA built in RF receiver tuned to 318 MHz.
- Operator length with push-pull tube fully retracted is 33 3/4”, mounting point to mounting point, arm stroke 15” max.
- Minimum gate length is 5 ft.
- Adjustable auto-close (3 to 120 seconds), and stall force potentiometers.
- Power terminal block accommodates a transformer or solar panels (not both).
- Accessory terminal block fully compatible with LPA push button controls, digital keypads, loops detectors, etc.
- Control board allows connection of safety edge sensors and photoelectric sensors.
- Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing.
- Direct drive for automatic gate lock.
### OPERATIONAL CAPACITY
- The Gate Capacity Chart shows approximate cycles, per day, you can expect from the LPA 2000XLS Automatic Gate Operator when powered with a transformer. Actual cycles may vary slightly depending upon the type and condition of gate and installation.
> Figure: PRO-SW2000XLS Gate Capacity Chart. Subtitle: “Estimated number of daily cycles, based on use with a transformer and one(1) 12 Volt battery.”
| Gate Length | 50 lb. | 100 lb. | 150 lb. | 200 lb. | 300 lb. | 400 lb. | 500 lb. |
|---|---:|---:|---:|---:|---:|---:|---:|
| 16 ft. | 135 | 120 | 105 | N/R | N/R | N/R | N/R |
| 14 ft. | 145 | 130 | 115 | 100 | 80 | N/R | N/R |
| 12 ft. | 155 | 140 | 125 | 110 | 90 | 70 | N/R |
| 5 to10 ft. | 165 | 150 | 135 | 120 | 100 | 80 | 60 |
Gate Weight
N/R - Not Recommended
**NOTE: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LB.**
To determine the number of cycles the gate operator will perform using solar panels, please see the specifications listed on page 2.
\* An operation cycle is one full opening and closing of the gate.
These specifications are subject to change without notice.
LPA 2000XLS Instruction Manual 1
## Page 12
# Before You Begin...
## 1. Determine Charging Option for Battery: Transformer OR Solar
> Figure: Boxed warning: “NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME. It will damage the control board.”
**IMPORTANT:**
- The 2000XLS’ 12 volt battery must be charged by either connecting the transformer (included) or solar panel kit [FM122] to the control board.
- The transformer is designed for indoor use. If the transformer can be plugged only into an outside electrical outlet, a weatherproof cover/housing (available at local electrical supply stores) must be used.
- If your gate is more than 1000 ft. from an AC power source, you will need to use at least 5 watts solar charging power to charge the battery [FM122]. Refer to the Solar Panel and Gate Activity chart below.
- All low voltage wire used with the GTO Gate Operator must be 16 gauge dual conductor, stranded, direct burial wire [RB509]. Do not run more than 1000 ft. of wire.
## Solar Panel and Gate Activity Chart
> Figure: Drawing of a solar panel on a stand with wire extending below it.
The table and map illustrate the maximum number of gate cycles to expect per day in a particular area when using from 5 to 20 watts of solar charging power. The figures shown are for winter (minimum sunlight).
| Winter Ratings for 12 V Single Gate | Zone 1 | Zone 2 | Zone 3 |
|---|---:|---:|---:|
| 5 watts | 4 | 8 | 13 |
| 10 watts | 8 | 16 | 26 |
| 15 watts | 11 | 20 | 30 |
| 20 watts | 14 | 28 | 38 |
Accessories connected to your system will draw additional power from the battery.
10 Watt Solar Panel [FM123]
5 Watt Solar Panel [FM122]
> Figure: Map of the United States, including Alaska and Hawaii, divided into solar zones. Labels: “Zone 1” across the northeastern/upper central area; “Zone 2” across the southeastern/central band; “Zone 3” across the western/southwestern area, Alaska/Hawaii inset, and southern Florida/Caribbean area. Shading and horizontal line patterns indicate zone boundaries.
2 LPA 2000XLS Instruction Manual
## Page 13
### 2. Check Direction of Gate Swing
The 2000XLS is designed for PULL-TO-OPEN installations.
PUSH-TO-OPEN installations require a Push-To-Open Bracket [3471H]. Please refer to specific Push-To-Open Installation Information on page 19.
> Figure: Two gate-swing diagrams. Left diagram: “Your Property”; gate swing arrow labeled “Pull-To-Open (arm retracts to open).” Right diagram: “Your Property”; gate swing arrow labeled “Push-To-Open (arm extends to open).”
### 3. Prepare the Gate
- The gate must be plumb, level, and swing freely on its hinges.
- The gate must move throughout its arc without binding or dragging on the ground.
- Wheels must NOT be attached to the gate.
- Gates over 250 lb. should have ball bearing hinges with grease fittings.
- Post must be secured in the ground with concrete (minimizes twist/flex when the operator is activated).
- Make sure there is a stable area for mounting the gate bracket (this may require the addition of a horizontal or vertical cross member).
- We recommend you position the operator near the center-line of the gate to keep the gate from twisting and flexing, and to avoid back-splash from rain.
> Figure: Chain-link double-gate drawing identifying installation requirements: A – Level; B – Plumb; C – Free Swinging; D – Posts Secured in Concrete; E – Centerline Mounting; F – Good Working Hinges. Adjacent drawings label “Horizontal Cross Member” and “Vertical Cross Member.”
### 4. Gate Grounding
- Shorter cable is better, 1 to 2 feet recommended.
- Bolt ring terminal at end of cable 4 - 6 inches above ground level.
R4196 Kit Includes:
1. Ground Rod Clamp
2. 6 AWG Wire (3 feet)
**NOTE:** No grounding system absolutely protects against lightning strikes. If installed correctly, a grounding system will help minimize damage to your gate opener.
> Figure: Gate grounding drawing. A metal gate post is connected by “6 AWG Wire” to an “8 Foot Ground Rod,” specified as “5/8” Copper Clad Steel (not included) - available at local homecenter and hardware stores -.” The wire is secured to the rod using a “Ground Rod Clamp” marked 1; “6 AWG Wire” is marked 2. Arrows identify the metal gate post, clamp, wire, and ground rod.
## Page 14
### 5. 2000XLS Parts List
> Figure: Parts layout showing:
>
> - Customer Support Card (1)
> - Operator Arm (1), PRO2000ARMXLS
> - 6’ Power Cable
>
> **BRACKET BOX - HB100**
>
> - Closed Position Stop Plate (1)
> - Gate Bracket (1)
> - Post Bracket (2)
> - Post Pivot Bracket (1)
>
> **HARDWARE BAG - H101P**
>
> - 8" Nylon Cable Tie (14)
> - 3/8" x 8" Bolt (4)
> - 3/8" x 2-3/4" Bolt (2)
> - 3/8" x 2" Bolt (1)
> - 5/16" x 1-3/4" Bolt (1)
> - 3/8" x 1-1/2" Clevis Pin (2)
> - Hairpin Clip (2)
> - 3/8" Washer (9)
> - 3/8" Lock Washer (7)
> - 3/8" Nut (7)
> - 5/16" Washer (1)
> - 5/16" Nut (1)
> - 3/8" x 3/16" Bushing (2)
> - 2" Screw (5)
## Page 15
> Figure: Included components: GTO Transmitter (1); Battery (1); Transformer (1); Wire Harness (1); Control Box w/ Battery Box (1); Warning Signs (2). Warning sign text: “WARNING”; “Moving Gate Can Cause Injury Or Death”; “1. KEEP CLEAR! Gate may move at any time. 2. Do not allow children to operate gate or play in gate area. 3. This gate is for vehicles only. Pedestrians must use a separate entrance.”
> Figure: Tool illustrations labeled Drill, Drill Bit, Pen, Center Punch, Pliers, Hack Saw, Hammer, Flat Head Screwdriver, Open End Wrenches, Phillips Head Screwdriver, Level, Clamps Small, Medium, Large, Adjustable Wrench, Wire Stripper, Small Flat Head, and Tape Measure.
### 6. Tools Needed
- Power Drill
- Level
- Wire Strippers
- Open End Wrenches: 9/16” and 1/2”
- Drill Bits: 3/8”
- Hacksaw or Heavy Duty Bolt Cutters
- Small (Flat Head) Screwdriver
- Phillips Screwdriver
- C-Clamps: small, medium, and large
- Adjustable Wrench
- Pliers
- Tape Measure
- Center Punch
- Extra person will be helpful
### 7. Materials You may Need for the Installation:
Depending on the type of gate and post, you may need some additional materials/hardware.
- Low voltage wire [RB509]. Length depends upon the distance between the transformer power supply and the control box. (Page 14)
- If the gate is more than 1000’ away from an AC power source you will need to use at least one 5 watt Solar Panel [FM122] to trickle charge the battery. (Page 2)
- PVC Conduit. (Page 6)
- The diameter of the post should be at least 6” in order to mount the post bracket. (Page 7)
- Depending upon the diameter of the post, you may need longer bolts than those provided. Bolts should be at least 1” longer than the diameter of the post. (Page 7)
- Metal plate for wooden posts. (Page 10)
- A horizontal or vertical cross member or mounting plate may be needed to mount the operator to the gate. (Page 3)
- Some types of installations require U-Bolts. (Page 11)
- Surge protection for transformer. (Page 16)
- Weatherproof cover for transformer if installed outside. (Page 16)
- For push-to-open applications you must have PTO Bracket [3471H). (Page 19)
## Page 16
# Installation Overview for Pull-To-Open Gate
**PUSH-TO-OPEN** installation instructions begin on page 19.
Example of an installation on a chain link fence:
> Figure: Pull-to-open chain-link gate installation overview. Labels identify: Control Box / Battery Box; Gate Swings Evenly and Freely Hung Firmly and Plumb; Horizontal Cross Member; Post Bracket Assembly; Single Gate Opener; Gate Bracket; Warning Sign; Power Cable; Closed Position Stop Plate; Fence Post Set in Concrete; PVC conduit (not included) to protect wire from lawn mowers and weed eaters. A “120 Volt indoor Transformer” is shown with “(surge protector not supplied).” Text and arrow specify: “Run 1000' (max.) of low voltage wire to control box from transformer (wire not included).”
**IMPORTANT:** To achieve the most efficient leverage for the gate opener and ensure long trouble free service, the gate opener needs to be installed within the following parameters.
The diagrams below show the optimum positions for the gate opener arm in relation to the gate in the open and closed positions. Be sure the position of the gate opener and brackets allows for 2" of clearance between the gate and the opener in both the open and closed positions.
> Figure: Gate in the OPEN POSITION diagram. The operator arm and gate post are shown with arrows identifying a “Pinch Area” and “2" minimum” clearance between gate and opener.
> Figure: Gate in the CLOSED POSITION diagram. Labels and arrows identify “2" minimum” clearance, “Pinch Area,” and “MAX 15"” along the operator arm.
> Figure: Post bracket alternative mounting diagram. Text: “If the gate post is larger than 6" the Post Pivot Bracket can be removed and the center hole of the Post Bracket can be the mounting point for the gate opener.” Arrow labels the “Center hole of post bracket.”
## Page 17
We recommend you position the opener near the centerline of the gate to keep the gate from twisting and flexing and to avoid backsplash from rain water.
### The Post Bracket Assembly
The position of the post bracket assembly determines the leverage and efficiency of the opener. The post bracket assembly position also sets the clearance between the opener and the gate in the open and closed positions.
The post bracket works well for installations on round and square fence posts. Because the post bracket carries the entire thrust of the active opener, bolts must completely penetrate the post.
On wood posts, place a metal plate or washer (not supplied) between the nuts and the post to prevent the thrust of the opener from pulling the bolts and washers out of the wood.
The post pivot bracket may not be necessary on posts larger than 6" in diameter (see page 6). Fence posts smaller than 6" in diameter or 6" square should be made of metal instead of wood to remain stable while the opener is moving the gate.
> Figure: Diagram of post bracket assembly mounted to round and square wooden posts. Labels: “Wooden Post,” “Metal Plate,” “Post Bracket,” “Post Pivot Bracket,” and “Post Bracket Assembly.” A detail circle shows the Post Pivot Bracket positioned between two Post Brackets. Bolts pass completely through each post, with a metal plate at the outer nut.
### Reinforcing Gates for the Gate Brackets
We recommend using a muffler clamp, wood, or metal, to reinforce thin-walled tube gates, or wood to reinforce panel gates as shown. These reinforcement methods will prevent damage to the opener and gate. Additional hardware may be needed depending on the installation.
> Figure: “Muffler Clamp for Gate Bracket” diagram. A Gate Bracket is bolted to a Thin Walled Tube Gate reinforced with a “Muffler Clamp (not supplied).” Arrows identify the muffler clamps, gate bracket, and thin-walled tube gate.
> Figure: Diagram showing a Gate Bracket mounted on a tubular gate with “Wood or Metal Reinforcement (not supplied)” behind the bracket. Label: “Wood or Metal Reinforcement.”
> Figure: Diagram showing a Gate Bracket mounted to a Panel Gate using vertical “1" x 6" Wood Reinforcement.” Labels: “Panel Gate,” “Gate Bracket,” and “1" x 6" Wood Reinforcement.”
LPA 2000XLS Instruction Manual 7
## Page 18
# Install the Operator
### Step 1
Insert the 3/8" x 2" bolt through the center hole of the post brackets and post pivot bracket as shown. Fasten a 3/8" lock washer, 3/8" washer and 3/8" nut on the end of the bolt. **DO NOT** overtighten the nut because the post pivot bracket will have to be adjusted later.
> Figure: Exploded assembly diagram. A “3/8" x 2" Bolt” passes through a Post Bracket, Post Pivot Bracket, and second Post Bracket. Hardware below is labeled “3/8" Washer,” “3/8" Lock Washer,” and “3/8" Nut.”
### Step 2
Attach post bracket assembly to the rear mount of the opener with a clevis pin and a 3/8” washer. Secure the clevis pin with a hairpin clip.
> Figure: Diagram of the rear of the Operator attaching to the Post Bracket Assembly. Labels: “Clevis Pin,” “Bushing,” “Rear Mount,” “Operator,” “Hairpin Clip,” and “Post Bracket Assembly.” Dashed alignment line shows the clevis pin installation order.
### Step 3
Attach gate bracket to the front mount of the opener with a clevis pin and a 3/8” bushing. Secure the clevis pin with a hairpin clip.
> Figure: Exploded diagram of Operator Front Mount attaching to Gate Bracket. Labels: “Front Mount,” “Clevis Pin,” “Gate Bracket,” “Bushing,” and “Hairpin Clip.” Dashed vertical line indicates assembly order.
### Step 4
With the gate in the fully open position and the opener arm fully retracted, adjust the post bracket assembly and gate bracket until the opener is level. While holding the opener level, use C-clamps to temporarily secure the post bracket assembly and gate bracket to the post and gate.
> Figure: Installation diagram with gate in open position. The Operator is mounted between a Fence Post and gate cross member and held in place with two C-clamps. Labels: “Post Bracket Assembly,” “Level Operator,” “LEVEL horizontal cross member,” “Gate Bracket,” “Gate In Open Position,” and “Fence Post.”
LPA 2000XLS Instruction Manual 8
## Page 19
### Step 5
After verifying that you have the best position for the post pivot bracket in the open position, insert the 5/16" x 1-3/4" bolt through the aligned holes of the post bracket and post pivot bracket to hold it in place. Remove the clevis pin from the front mount and while supporting the gate opener, swing the gate and gate opener to the closed position.
**TIP:** Turn the post pivot bracket over for more hole alignment options. You can also move the entire post bracket assembly to different positions on the post.
### Step 6
Be sure the position of the gate opener and brackets allows for 2” of clearance between the gate and the opener in both the open and closed positions (A), and maintaining a maximum distance of 15” from the clevis pin opening of the retracted opener arm to the gate bracket with the gate in the closed position. (B) see *graphic to right*. This mounting position will give the opener the most efficient leverage point for operation and provides the least possible pinch area.
Again, check the clearance and be sure that the gate opener is not binding at the post pivot bracket.
If you don't have the required clearance, or if the gate opener is binding on the post pivot bracket, remove the 5/16" x 1-3/4" bolt and readjust the post pivot bracket.
> Figure: Gate clearance diagram. Top view, “Gate in the CLOSED POSITION,” shows the operator under the gate cross member with a “2" minimum” clearance marked as (A), a “Pinch Area,” and “MAX 15"” marked as (B) between the retracted opener arm clevis-pin opening and gate bracket. Inset detail states: “Be sure gate opener and bracket don't bind.” Lower view, “Gate in the OPEN POSITION,” shows another “Pinch Area” and “2" minimum” clearance.
> Figure: Detail of post bracket alignment. Labels: “Determine Best Hole Alignment to Achieve 2" Clearance,” “Post Bracket,” “Post Pivot Bracket,” “5/16" x 1-3/4" Bolt,” “5/16" Washer,” and “5/16" Nut.” Arrows indicate bolt, washer, and nut assembly order.
### Step 7
When the post bracket assembly is in the optimum position for clearance and freedom of movement, reattach the opener to the gate bracket (gate in the open position); recheck the gate opener level; make sure the brackets are clamped securely. Secure the 5/16” x 1-3/4” bolt with a 5/16” washer and 5/16” nut.
### Step 8
Mark reference points for bolt holes on the post through middle of post bracket assembly slots. Mark reference points for bolt holes on the gate cross member through middle of gate bracket slots. After marking your reference points, remove the opener and brackets from the fence and gate.
> Figure: Gate in open position with operator level against a horizontal cross member. Label: “Gate In Open Position,” “LEVEL horizontal cross member,” and “Mark cross member through middle of gate bracket slots and drill 3/8" holes.” An arrow points to the gate bracket slots.
> Figure: Post bracket marking and drilling diagram. Label: “Mark gate post through middle of bracket slots and drill 3/8" holes.” The Post Bracket Assembly is shown against a round post, with four bolt holes and four bolts aligned through the post.
LPA 2000XLS Instruction Manual 9
## Page 20
### Step 9
Drill 3/8" holes through post as marked. Fasten post bracket assembly to the fence post using four 3/8" x 8" bolts, lock washers and nuts. You must use bolts that completely penetrate the post.
### Step 10
Drill 3/8" holes through the gate cross member as marked. Mount gate bracket using two 3/8" x 2 3/4" bolts, lock washers, and nuts.
**NOTE:** After the gate opener installation is complete and operation of the opener system has been tested, you should remove excess bolt length extending beyond the tightened nuts with a hacksaw or bolt cutters.
> Figure: Post bracket mounting examples. Heading: “EXAMPLES,” “TOP VIEW,” and “SIDE VIEW.” Top-view examples are labeled “Round Metal Post” and “Square Metal Post.” Side-view examples are labeled “Square Wood Post” and “Round Wood Post.” Arrow text: “Remove excess bolt length with hacksaw or bolt cutters.”
### Gate Bracket Mounting Examples
> Figure: Gate bracket mounting examples. Left examples show “FRONT VIEW” and “SIDE VIEW” for “Round Tube & Chain Link Gate” and “Square Tube Gate.” Right examples show “FRONT VIEW” and “SIDE VIEW” of a decorative gate mounting. Labels: “Mounting Plate Created for Decorative Gate (required but not supplied)” and “Remove excess bolt length with hacksaw or bolt cutters.”
## Attach Operator Arm
Attach the opener to the securely bolted post bracket assembly and gate bracket using clevis pins, bushings, and hairpin clips, or optional Pin Lock [FM345] (page 30). Verify that the opener is level and adjust the post bracket assembly, if necessary.
> Figure: Installed operator arm with gate in open position. Labels: “Post Bracket Assembly bolted to gate post,” “Level Operator,” “LEVEL horizontal cross member,” “Gate Bracket bolted to gate cross member,” “Clevis Pin, Bushing and Hairpin Clip” at both mounting ends, “Gate Post,” and “Gate In Open Position.” Arrows identify the bracket connections and hardware.
LPA 2000XLS Instruction Manual 10
## Page 21
# Installation of the Closed Position Stop Plate
The 2000XLS Gate Operator firmly holds the gate in the closed position using the closed position stop plate. The closed position stop plate helps stabilize the gate leaf in the closed position. To further enhance the stability and security of your gate, install the optional GTO Automatic Gate Lock (see Accessory Catalog).
**Step 1**
Remove hairpin, clevis pin, and washer from front mount and close the gate (remember to support operator). Fasten the closed position stop plate to the end of the gate frame on the gate centerline, but do not tighten it completely. Slide the stop plate toward the fence post until they touch (see illustration). Once you have moved the stop plate to the correct position, tighten its hardware completely.
Use the appropriate hardware for your type of gate (use U-bolts if you have a tube or chain link gate; wood or lag screws for wood gates; etc.). This hardware is not provided.
**Step 2**
Return the gate to the open position and reattach the gate opener to the gate.
> Figure: Diagram of a gate opening from a fence post. Labels: “Gate Hinge,” “Closed Position Stop Plate,” and “The gate must open 80º (min.) to 110º (max.).” A curved arrow shows the gate opening arc. Lower detail shows the closed position stop plate mounted on metal posts with U-bolts, with “SIDE VIEW” and “TOP VIEW” labels. Parts are labeled “Gate Post” and “Fence Post.”
LPA 2000XLS Instruction Manual 11
## Page 22
# Mount the Battery Box / Control Box
**Step 1**
Remove the Control box from the Battery Box by removing the three screws as shown in Illustration A.
> Figure: Illustration A shows a Battery Box behind a Control Box. Three screws are shown being removed with arrows. Labels: “Battery Box,” “Control Box,” and “Illustration A.” A circular inset shows a mounting screw detail.
**Step 2**
Mount the Battery Box using the screws (provided) or another secure mounting method. The battery/control box must be mounted at least 3 feet above the ground to protect it from rain splash, snow, etc., and at least 3 feet from an AC power source to prevent electrical interference.
**Step 3**
Slide the battery into position with the terminals at the TOP as shown in Illustration B.
> Figure: Illustration B shows a battery being slid into the Battery Box, indicated by an arrow. Label: “Illustration B.”
> Figure: Diagram of a control box installed on a piece of wood mounted to a chain-link gate post. Labels: “Control Box” and “Piece of Wood for Mounting.” The gate operator and gate are also depicted.
> Figure: Rear view of the battery box showing four mounting locations. Label: “Screw Placement Guides.” Interior labels read “LOCATION FOR MOUNTING SCREWS.”
This device complies with FCC rules Part 15. Operation is subject to the following conditions:
1. This device may not cause harmful interference.
2. This device must accept an interference that may cause undesired operation.
Transmitter distance may vary due to circumstances beyond our control. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
LPA 2000XLS Instruction Manual 12
## Page 23
# Connecting the Battery Box / Control Box
**Step 4**
## Connecting the Battery
Verify that the ON/OFF switch is in the OFF position.
Connect the BATTERY WIRE HARNESS wires to the battery — RED wires to POSITIVE (+) battery terminal and BLACK wires to NEGATIVE (–) battery terminal.
The BATTERY WIRES from the CONTROL BOARD should extend through the KNOCK-OUT in the back of the CONTROL BOX. Plug the BATTERY HARNESS wires into the wires coming from the CONTROL BOX.
> Figure: Open Battery Box containing a battery with red and black wire connections. The separated Control Box is at right, with red and black wires extending from its back through a knock-out and connected to the battery wire harness. Labels: “Battery,” “Battery Wire Harness with In-Line Fuse,” and “Back of Control Box.” Arrows identify the plug connections.
**Step 5**
Tuck the excess battery leads into the battery box and reattach the CONTROL BOX to the BATTERY BOX
> Figure: Battery Box and Control Box being reattached with screws. Labels: “Battery Box” and “Control Box.” Arrows show the three screws being installed; circular inset shows a mounting detail.
**Step 6**
## Remove the Control Box Cover
Remove the four (4) control box cover screws and remove the cover to access the CONTROL BOARD.
> Figure: Control Box Cover removed from the box, exposing the Control Board. Four screws are shown with arrows. Labels: “Control Board” and “Control Box Cover.” Circular inset shows a mounting detail.
**Step 7**
Attach antenna to control box cover. First, remove the Phillips screw (labeled ANT) from the control box cover. Place one end of the antenna coil over the antenna plug (antenna wire will fit into groove). Tighten the Phillips screw to secure antenna.
> Figure: Control box cover with antenna plug. A Phillips screwdriver removes/installs the screw above the plug; curved arrows show screwdriver rotation and a downward arrow shows screw placement. The antenna wire/coil is shown entering the groove.
LPA 2000XLS Instruction Manual 13
## Page 24
# Connect Operator Power Cable
Bring power cable into the control box through a strain relief slot, leaving enough wire to reach the FIRST OPR. terminal block.
Insert the individual power cable wires into appropriate terminals on the FIRST OPR. terminal block (white to WHT; green to GRN; red to RED; black to BLK). Tighten the set screws.
> Figure: Wire-terminal connection examples. “Correct” shows wire inserted properly beneath the terminal screw. Two “Wrong” examples show “Screwed into wire insulation” and “Exposed strands of wire.”
> Figure: Control box interior and control board. The FIRST Opener Power Cable enters through “Strain Relief Slots” and connects to “FIRST OPR.” terminals labeled “WHT,” “GRN,” “RED,” and “BLK.” Label: “(Battery Wires Not Shown).” Control-board readable labels include: “STATUS”; “1st OPR.”; “OPEN < JOG > CLOSE”; “2nd OPR.”; “PWR.”; “SET LIMIT”; “MIN”; “STALL FORCE”; “MAX”; “OFF”; “120 SEC.”; “AUTO CLOSE”; “REMOVE JUMPER FOR PUSH TO OPEN OPTION”; “SFTY.”; “EXIT”; “CYCLE”; “EDGE”; “SENSOR”; “COMMON”; “LOCK+”; “LOCK–”; “FIRST OPR.”; “SECOND OPR.”; “14 VAC OR SOLAR”; “BATT +”; “BATT –”; “ON OFF”; “JP1”; “PF1”; “K1”; “K2”; “K3”; “K4”; “VAR1” through “VAR6”; “R4722”; and “GTO Inc. Tallahassee, FL.”
# Connect the Transformer
(*Solar Instructions on Page 21*)
> Figure: Warning box containing: “NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME!”
## IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE:
- The only wire acceptable for use with GTO products is 16 gauge stranded, low voltage, direct burial wire. This gauge enables the transformer to provide an adequate charge through the control board to the battery at distances up to 1000'.
- DO NOT use telephone wire or solid wire.
- NEVER SPLICE WIRES. Splicing permits corrosion and seriously degrades the wire's ability to carry an adequate current.
**Step 1**
Make sure the power switch is OFF.
**Step 2**
Select the electrical outlet where you will plug the transformer. Measure the distance from this outlet to the control box following the path where the wire will be laid. (Allow for an additional 6” to be pulled into the control box.)
> Figure: Detail of control box interior showing the ON/OFF Switch. An arrow points to the switch, and a horizontal arrow is labeled “ON/OFF.”
LPA 2000XLS Instruction Manual 14
## Page 25
### Step 3
Lay the low voltage wire in a trench following a path from the selected electrical outlet to the control box. Wires coming up from the ground should be run through PVC conduit to protect them from accidental damage. Be sure to bury the wire laid in the trench.
> Figure: Installation drawing of a gate, control and battery box, gate opener, and 120 Volt indoor transformer. Labels: “Control and Battery Box,” “Gate Opener,” “120 Volt indoor Transformer,” “(surge protector not supplied),” “Run 1000' (max.) of low voltage wire to control box from transformer (wire not included),” and “PVC conduit (not included) to protect wire from lawn mowers and weed eaters.” The low-voltage wire runs underground through PVC conduit and up to the control box.
### Step 4
Bring enough wire up through the PVC conduit to reach the control board.
### Step 5
Strip 3/16” off the ends of the low voltage wire and twist tightly. Attach these ends to the 14VAC OR SOLAR terminals located on the terminal block. Be certain not to let the exposed wires touch each other!
Insert one transformer wire into a 14VAC OR SOLAR terminal. Insert the other transformer wire into the remaining 14VAC OR SOLAR terminal. The transformer wires can be connected to the 14VAC OR SOLAR terminals regardless of color/polarity.
Tighten set screws against exposed end of wires.
> Figure: Open control box showing control board and wiring. An arrow identifies “Low Voltage Wire from Transformer or Solar” entering the box and connecting to the “14 VAC OR SOLAR” terminal block. Readable board labels include: “STATUS,” “1st OPR.,” “OPEN < JOG > CLOSE,” “2nd OPR.,” “MIN,” “MAX,” “OFF,” “120 SEC.,” “STALL FORCE,” “AUTO CLOSE,” “PWR.,” “SET LIMIT,” “REMOVE JUMPER FOR PUSH TO OPEN OPTION,” “SFTY. EXIT,” “CYCLE EDGE SENSOR COMMON,” “LOCK+,” “LOCK–,” “FIRST OPR.,” “SECOND OPR.,” “WHT,” “GRN,” “RED,” “BLK,” “BATT +,” “BATT –,” “14 VAC OR SOLAR,” “VAR1” through “VAR6,” “JP1,” “PF1,” “K1” through “K4,” “ON OFF,” and “R4722 GTO Inc. Tallahassee, FL.”
> Figure: Enlarged circular detail of the control-board terminal block. Red and black low-voltage wires, labeled “Low Voltage Wire from Transformer or Solar Panel,” point into the two “14 VAC OR SOLAR” terminals. Nearby labels: “SECOND OPR.,” “WHT,” “GRN,” “RED,” “BLK,” “K4,” “VAR6,” and “ON OFF.”
### Step 6
At the AC outlet, strip 1/2” of insulation from the ends of the low voltage wire. Attach these stripped ends to the transformer terminals.
> Figure: Drawing of a screwdriver tightening a transformer terminal with two low-voltage wires attached. Text: “Make sure the exposed wires do not touch each other!”
LPA 2000XLS Instruction Manual 15
## Page 26
### Step 7
Plug the transformer into the electrical outlet. Use of a surge protector with the transformer is strongly recommended. If electrical outlet is located outdoors, outlet and transformer should be protected by a weatherproof cover.
> Figure: Transformer plugged through a surge protector into an electrical outlet. Labels: “Transformer” and “SURGE PROTECTOR.”
# Set the CLOSED Position Limit for PULL-TO-OPEN Installation
*Your transmitter must be able to operate the gate. If not, see "Personal Transmitter Setting" on page 18.*
Note: The OPEN limit is when the opener is fully retracted and the gate is in the full open position. The open limit setting can only be adjusted by moving the gate bracket. To achieve the optimum closed position, you must adjust the CLOSED limit setting:
### Step 1
Make sure the Control Box is ON and that the gate is in the OPEN POSITION (arm fully retracted).
### Step 2
Press and HOLD the 1st Opener CLOSE button on the control board and be prepared to RELEASE the button when the gate reaches the desired closed position/limit. Use the JOG OPEN and CLOSE buttons to "fine tune" the gate position if neccessary.
> Figure: Detail of control-board upper controls. Arrows identify “FIRST Opener JOG Buttons,” “SET LIMIT Button,” and “SET LIMIT Light.” Readable labels include: “STATUS,” “1st OPR.,” “OPEN < JOG > CLOSE,” “2nd OPR.,” “PWR.,” “SET LIMIT,” “MIN,” “MAX,” “STALL FORCE,” “OFF,” “120 SEC.,” “AUTO CLOSE,” and “REMOVE JUMPER FOR PUSH TO OPEN OPTION.”
### Step 3
With the gate in in the desired closed position PRESS and HOLD the SET LIMIT button until the alarm and RED Light come on. Then release the button.
NOTE: The opener must be extended more than 7 inches to set limits.
### Step 4
NOTE: When the control box cover is removed the receiver range is reduced to less than 5 feet.
Press the transmitter button once (within 5 feet of the control board) and allow the gate to fully open. The alarm will beep once when the gate reaches the OPEN LIMIT. This indicates the limits for the arm is programmed in memory.
### Step 5
Press the transmitter button and allow the gate to fully close to verify that it stops at the desired position. Repeat Steps 2-4 if correction is needed.
16 LPA 2000XLS Instruction Manual
## Page 27
# Adjust the Stall Force Setting
The Stall Force potentiometer controls the the amount of force the opener will apply against an obstruction before it stops and reverses direction within two seconds.
IMPORTANT: The Stall Force setting will need to be adjusted to compensate for the weight and size of your gate. For safety reasons, use the lowest possible setting to operate the gate.
The Stall Force potentiometer on the control board operates like a volume control on a radio. Use a small flat blade screwdriver to turn the arrow in the center of the potentiometer. Adjust the sensitivity from the MINIMUM position just to the point where the gate operates smoothly without obstructing from its own weight or wind conditions.
NOTE: You may need to increase the stall force in cold weather due to increased resistance from gate hinges.
> Figure: Control-board detail with a magnified callout of the Stall Force adjustment. The callout shows a screwdriver arrow at the center adjustment and labels “MIN,” “MAX,” and “STALL FORCE.” The board detail includes “STATUS,” “STALL FORCE,” “AUTO CLOSE,” “OFF,” “120 SEC.,” and “REMOVE JUMPER FOR PUSH TO OPEN OPTION.”
# Set Auto-Close Time
The Auto-Close determines how long the gate will remain open before it automatically closes. The factory setting is OFF. Use a small flat blade screwdriver, you can adjust the settings to OFF, or from 3 to 120 seconds.
NOTE: The Auto-Close timer will only funtion if the gate is in the fully open position.
> Figure: Control-board detail with a magnified callout of the Auto-Close adjustment. The callout shows a screwdriver arrow at the center adjustment and labels “OFF,” “120 SEC.,” and “AUTO CLOSE.” The board detail includes “STATUS,” “STALL FORCE,” “AUTO CLOSE,” and “REMOVE JUMPER FOR PUSH TO OPEN OPTION.”
LPA 2000XLS Instruction Manual 17
## Page 28
# Personal Transmitter Setting
All GTO transmitters have a standard setting and are ready to operate your Mighty Mule Gate Opener. For your safety and security, we strongly recommend that you replace the factory setting with your own personal setting.
NOTE: If you have multiple transmitters, you should adjust all of them at this time.
### Step 1
Use a small phillips head screw driver to remove the transmitter cover.
> Figure: Open transmitter with cover removed, showing battery, DIP switches, LED, and screws. Readable labels include: “LED,” “A23S 12V,” “ALKALINE BATTERY,” and switch positions “+,” “0,” and “–.”
### Step 2
Set the transmitter DIP switches using a small screwdriver. There are nine (9) switches; each can be placed in three different positions (+, 0, –). DO NOT set all the switches in the same position, such as all +, all 0, or all –. Once the DIP switches have been reset, replace and close the access cover.
WARNING: No other adjustments should be made inside the transmitter.
> Figure: DIP-switch configuration drawing. Nine switches are numbered “1 2 3 4 5 6 7 8 9,” with position markings “+,” “0,” and “–.” Label: “ECE.” A perspective drawing shows the nine switches.
### Step 3
Program the new setting in the control board memory.
A. Slide the control box ON/OFF switch to the OFF position.
B. Press and hold the transmitter button while sliding the ON/OFF switch to the ON position.
C. Continue to hold the transmitter button until the alarm sounds (3-5 seconds).
D. Release the transmitter button. The new transmitter setting is now programmed.
E. Verify that the transmitter operates the gate.
NOTE: It is NOT necessary to remove the cover of the control box to program the new transmitter code, but when the control box cover is removed the receiver range is reduced to less than 5 feet.
> Figure: Open control box with a hand pressing a transmitter button. An arrow points to the control-box “ON/OFF Switch,” with “ON/OFF” and directional arrows shown.
**FCC WARNING:** Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. In accordance with FCC Part 15, Section 15.21, the manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could VOID the user authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. The external solid wire antenna was used during FCC testing. Substitutes should not be used.
However, there is no guarantee that interference will not occur in particular installations. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.
18 LPA 2000XLS Instruction Manual
## Page 29
# Push-To-Open Installation Information
**Swinging gates shall not open into public access areas!**
A “Push-to-Open” gate opens out from the property (operator arm extends to open the gate). A Push-To-Open installation requires the purchase of a Push-To-Open Bracket [347IH].
**In a Push-To-Open installation the operator is installed while the gate is in the CLOSED POSITION.**
## Install the Operator
Follow directions for installing the 2000XLS beginning on page 8. *The Push-To-Open installation differs from the Pull-To-Open installation in the following ways:*
1. In a Push-To-Open installation, the arm fully extends to open the gate, and it fully retracts to close the gate. (C)
2. You will install the operator while the gate is in the **CLOSED POSITION (arm fully retracted).** (A)
3. You must use the Push-to-Open Post Pivot Bracket [347IH] in the Post Bracket assembly. (B)
4. IMPORTANT: While determining the mounting point for the post pivot bracket assembly be sure that the position allows for 2” clearance between the gate and the operator in both the open and closed positions (see diagram below). This clearance will give the operator the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area. (C)
> Figure: Diagram A, “Gate In Closed Position.” A gate post and gate horizontal cross member are shown with the operator installed level. Labels and arrows identify: “Gate Post,” “Level Operator,” “LEVEL horizontal cross member,” and “Clevis Pin, Bushing and Hairpin Clip.”
>
> Figure: Exploded bracket drawing B. Labels identify: “3/8" x 2" Bolt,” “Post Bracket” (upper and lower), “Push-To-Open Pivot Bracket,” “3/8" Washer,” “3/8" Lock Washer,” and “3/8" Nut.”
>
> Figure: Diagram C showing gate/operator clearance in open and closed positions. In the open position, a “15"” dimension is shown and the “Pinch Area” is identified. In the closed position, arrows show “2" minimum” clearance at two locations; another “Pinch Area” is identified.
>
> Figure: Troubleshooting Wizard mascot illustration beside the note: “*The Troubleshooting Wizard has detailed information on Push-To-Open installations.”
LPA 2000XLS Instruction Manual 19
## Page 30
### Step 1: Remove Push-To-Open Jumper
A. Make sure the control box power switch is OFF.
B. Use small pliers to remove the JUMPER for PUSH-TO-OPEN applications.
C. Turn power switch ON. The control board is now configured to push the gate open. (Keep the jumper, as it is necessary if there is ever a need to convert the opener for Pull-To-Open.)
> Figure: Control-board illustration identifying the “Push-To-Open Jumper,” with an arrow pointing to the jumper location. Readable board labels include: “STATUS,” “1st OPR.,” “OPEN < JOG > CLOSE,” “2nd OPR.,” “MIN,” “MAX,” “STALL FORCE,” “OFF,” “120 SEC.,” “AUTO CLOSE,” “PWR.,” “SET LIMIT,” and “REMOVE JUMPER FOR PUSH TO OPEN OPTION.”
### Step 2: Set the Open Position Limit (Push-to-Open)
The CLOSED limit is when the opener is fully retracted and the gate is in the closed position. The closed limit setting can only be adjusted by moving the gate bracket.
To acheive the optimum open position, you must adjust the OPEN Limit setting:
A. If not already ON slide the ON/OFF switch on the Control Box to the ON position and make sure the arm is in the CLOSED POSITION (fully retracted).
B. Press and HOLD the FIRST Opener OPEN button on the control board and be prepared to RELEASE the button when the gate reaches the desired open position/limit. Use the JOG OPEN and CLOSE buttons to "fine tune" the gate position if neccessary.
C. NOTE: The opener arm must be extended more than 7 inches to set limits. With the gate in in the desired open position PRESS and HOLD the SET LIMIT button until the alarm and RED Light come on. Then release the button.
D. NOTE: When the control box cover is removed the receiver range is reduced to less than 5 feet. Press the transmitter button once and allow the gate to fully close. The alarm will beep once when the gate reaches the CLOSED LIMIT. This indicates the LIMITS for the arm are learned and stored in memory.
E. Press the transmitter button and allow the gate to fully open to verify that it stops at the desired positions. Repeat Steps B – D if correction is needed.
> Figure: Control-board illustration with arrows identifying “FIRST Opener JOG Buttons,” “SET LIMIT Button,” and “SET LIMIT Light.” Readable board labels include: “STATUS,” “1st OPR.,” “OPEN < JOG > CLOSE,” “2nd OPR.,” “MIN,” “MAX,” “STALL FORCE,” “OFF,” “120 SEC.,” “AUTO CLOSE,” “PWR.,” “SET LIMIT,” and “REMOVE JUMPER FOR PUSH TO OPEN OPTION.”
*Note: Must have a transmitter that operates the gate. If not, see Personalize Your Transmitter Setting on page 18.*
20 LPA 2000XLS Instruction Manual
## Page 31
# Solar Panel Instructions
**NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME!**
**It will damage the control board!**
**IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE:**
- The only wire acceptable for use with GTO products is 16 gauge stranded, low voltage, PVC sheathed wire. This gauge enables the solar panel to provide an adequate charge through the control board to the battery at distances up to 250'.
- **DO NOT** use telephone wire or solid wire.
### Step 1
Make sure the power switch is OFF.
> Figure: Drawing of the control-box interior identifying the “ON/OFF Switch.” An arrow marked “ON/OFF” indicates switch direction.
### Step 2
Strip 3/16" off the ends of the low voltage wire and twist tightly. Attach these ends to the 14VAC OR SOLAR terminals located on the terminal block. Be certain not to let the exposed wires touch each other!
### Step 3
Insert one solar panel wire into a 14VAC OR SOLAR terminal. Insert the other solar panel wire into the remaining 14VAC OR SOLAR terminal. The wires can be connected to the 14VAC OR SOLAR terminals regardless of color/polarity.
> Figure: Close-up control-board terminal drawing. A low-voltage wire enters terminals labeled “14 VAC OR SOLAR.” Label: “Low Voltage Wire from Transformer or Solar Panel.” Other readable terminal labels include “WHT,” “GRN,” “RED,” “BLK,” “FIRST OPR.,” “SECOND OPR.,” and “VAR6.”
>
> Figure: Control-box interior diagram showing low-voltage wire routed into the enclosure and connected to the “14 VAC OR SOLAR” terminals. Arrow label: “Low Voltage Wire from Transformer or Solar.” Readable board labels include “SFTY.,” “EXIT,” “CYCLE,” “EDGE SENSOR,” “COMMON,” “LOCK+,” “LOCK–,” “BATT +,” and “BATT –.”
### Step 4
Tighten set screws against exposed end of wires.
NOTE: For multiple panels, wire the panels in parallel as shown in this diagram.
> Figure: Two solar panels wired in parallel. Heading: “Solar Panels connect in PARALLEL.” Both positive conductors are labeled “RED”; both negative conductors are labeled “BLACK.”
> Figure: Troubleshooting Wizard mascot illustration with text: “24/7 Troubleshooting Wizard: http://support.gtoinc.com”
LPA 2000XLS Instruction Manual 21
## Page 32
# Connecting Accessories
Although GTO strongly recommends the use of additional safety devices, we do not endorse any specific brands. Only use products that are certified and listed to be in compliance with any applicable UL standards (Underwriters Laboratories) and national and regional safety codes.
Call GTO Sales at 1-850-575-0176 for information on compatible products for your specific application.
### Step 1
Turn control box OFF before connecting safety device wires to the control board. (Unplugging the transformer does not turn power to the opener OFF.)
### Step 2
Run wires from safety devices and other accessories through the strain relief openings in the bottom of the control box.
### Step 3:
**Follow directions in Accessory Installation Manuals.**
> Figure: Control-box interior diagram showing accessory wires routed through bottom strain-relief openings to the control board. Arrow label: “Accessory Wire.”
>
> Figure: Accessory wiring diagram. Control-board terminal labels and numbered connection points are shown: “SFTY.” (1), “EXIT” (2), “CYCLE” (3), “EDGE SENSOR” (4), “COMMON” (5), “LOCK+” (6), and “LOCK–” (7). Additional readable labels include “WHT,” “GRN,” “RED,” “BLK,” “FIRST OPR.,” and “SECOND OPR.”
>
> The diagram shows:
> - “Automatic Gate Lock,” connected to terminals 6 and 7.
> - “Edge Sensor,” connected to terminals 4 and 5.
> - “Push Button Control,” connected to terminals 3 and 5.
> - “Photo Beams,” connected to terminals 1 and 5.
> - “Digital Keypad,” connected to terminals 3 and 5.
> - “Gate Opening Sensor,” with wire labels “Blue,” “Black,” “Red +,” “Yellow,” and “Shield -”; connection numbers 2 and 5 are shown.
>
> Note beside Gate Opening Sensor: “Refer to Sensor manual for additional information if needed.”
**NOTE:** Connections are for typical applications. For additional connection options not illustrated here refer to the accessory manual for details.
22 LPA 2000XLS Instruction Manual
## Page 33
### Accessory Inputs
1. **SAFETY:** Typically for use with photo beam device, loop detector or other non-contact sensors
- Activation of this input while the gate is closing will cause the gate to stop and return to the opened position.
- Activation of this input while the gate is opening has no effect. (gate will continue to open)
- Activation of this input while gate is idle will prevent gate from closing.
- Activation of this input while at open limit will restart the auto close time (if enabled).
2. **EXIT:** Typically for use with exit loop or wand
- Activation of this input will open the gate if it’s not already at the open position.
- Activation of this input while at open limit will restart the auto close time (if enabled).
- Activation of this input while gate is open will prevent gate from closing.
3. **CYCLE:** Typically for use with doorbell button or hardwired keypad
- Each activation at this input will cycle the operation as follows:
… → OPEN → STOP → CLOSE → STOP → OPEN → …
4. **EDGE SENSOR:** Typically for use with contact edge sensor
- Activation of this input while gate is moving will cause it to reverse direction for 2 seconds.
- Activation of this input while idle will prevent gate from running.
5. **COMMMON:** Common/Negative terminal for accessory devices.
### 12 Volt Power (Maximum Current: 100 mA)
5. **COM:** Common/Negative terminal for accessory power source.
6. **LOCK +:** Power source for GTO/Mighty Mule accessories, i.e. Gate Opening Sensor [FM139].
### Lock Outputs
6. **LOCK +:** Positive terminal to connect Automatic Gate Lock [FM144].
7. **LOCK –:** Negative terminal to connect Automatic Gate Lock.
### Charge Power Inputs
8. **14VAC or SOLAR:** Power Input Terminals:
- Input terminals for transformer or solar panel.
- Non-polarity sensitive.
> Figure: Control-board diagram. At top are labels “STATUS,” “1st OPR.,” “OPEN < JOG > CLOSE,” “2nd OPR.,” “MIN,” “MAX,” “OFF,” “120 SEC.,” “STALL FORCE,” and “AUTO CLOSE.” A “SET LIMIT” button is shown. A jumper area is labeled “REMOVE JUMPER FOR PUSH TO OPEN OPTION,” with “JP1.” Terminal blocks are numbered 1 through 8. Inputs 1–5 are labeled “SFTY.,” “EXIT,” “CYCLE,” “EDGE SENSOR,” and “COMMON.” Terminals 6–7 are “LOCK+” and “LOCK–.” Terminal 8 is “14 VAC OR SOLAR.” Variable labels “VAR1” through “VAR6,” “PF1,” relays “K1” through “K4,” and battery labels “BATT +” and “BATT –” appear. First operator wiring is labeled “FIRST OPR.” with wires “WHT,” “GRN,” “RED,” and “BLK”; second operator wiring is labeled “SECOND OPR.” with “WHT,” “GRN,” “RED,” and “BLK.” An “ON OFF” switch and a plug/connector are depicted.
LPA 2000XLS Instruction Manual 23
## Page 34
# Column Installation
If this operator will be used with gates that are mounted on masonry, brick, or rock (etc.) columns, read the following carefully before proceeding
A. The simplest solution is to install the operator in a push-to-open configuration. The minimum clearance is easier to achieve and clearance is no longer a problem, since the operator will be pushing the gate away from the column instead of pulling it toward the column. It is recommended that you place a steel plate between the operator mounting brackets and masonry surface for additional strength.
B. If a push-to-open installation is impossible due to traffic hazards, terrain, etc., another option is to re-hang the gate. You may hang it on a post, either in the center of the column or at the back corner, or move the gate to the back corner of the column.
C. The most difficult solution is to cut a notch in the column to accommodate the operator and power cable. This job is NOT for the inexperienced!*
> Figure: Column mount example diagram. A shaded rectangular **Column** stands at left, with a horizontal **Gate** extending right from a circled **Hinge** at the column edge. An arrow labels the hinge. A **Pivot Bracket** below the hinge is attached near the column and is identified by an arrow. Dashed vertical and horizontal reference lines show dimensions: horizontal dimension **A** between the pivot-bracket location and hinge reference line; vertical dimension **B** from gate/hinge level to pivot-bracket level. Text states: “Column Mount Example (A + B can not exceed 15 inches) Example: If A is 6" then B cannot exceed 9".”
> Figure: Small wizard/gnome illustration beside the note: “*The Troubleshooting Wizard has detailed information on column mounting.”
LPA 2000XLS Instruction Manual 24
## Page 35
# Troubleshooting Guide
If your gate opener does not function properly, use this guide or use the online troubleshooter at
http://support.gtoinc.com before calling the GTO Service Department.
## VISUAL AND AUDIBLE DIAGNOSTIC INDICATORS
1. **VISUAL INDICATORS:**
a. **Power LED (Green):**
- **ON:** AC power or Solar power is present.
- **OFF:** There is no input power.
b. **Status LED (Yellow):** (while unit is running this LED will be OFF)
- Rapid blinking in random pattern: GTO’s transmitter 318 MHz signal is detected.
- Continuously ON: Battery is in fast charge mode.
- 1 Blink every 2 seconds: Battery is in float charge mode (battery is fully charged)
- OFF: Switch is in the OFF position or there is no input power for at least 60 seconds.
2. **AUDIBLE INDICATORS (ALARM/BUZZER):**
a. **Beeps upon power up:**
- This is normal self test when the unit is turned on.
b. **Continuous beep after power up:**
- Unit has learned new transmitter code, releasing the transmitter button will shut off the alarm.
c. **Rapid beeping:**
- Unit has encountered two (2) obstructions without reaching either limit. (Power cycle to reset the alarm)
- Transmitter will not operate the gate.
- Alarm will automatically shut off after 5 minutes; gate will remain disabled until control box is restarted.
d. **1 beep every 20 seconds:**
- Low battery is detected.
e. **1 beep every 2 second:**
- Position sensor is open circuit. Call GTO Service department.
f. **2 beeps every 2 second:**
- Position sensor is short circuit. Call GTO Service department.
g. **1 or more beeps when attempting to activate the opener:**
- Blown fuse.
- Battery is extremely low or damaged.
- Loose connection from battery to circuit board.
3. **IF THE GATE STOPS AND REVERSES DIRECTION**
a. Check the gate for binding or hinge damage.
b. Adjust stall force if necessary.
c. Check the position of the mounting brackets and readjust or tighten if necessary.
LPA 2000XLS Instruction Manual 25
## Page 36
## VOLTAGE READINGS
| Item | Reading |
|---|---|
| 14 Vac Transformer | 13.0 to 16.0 Vac |
| 10 W Solar panel | 18.0 to 22.0 Vdc |
Measure voltage at panel and control box w/ panel disconnected.
| Item | Reading |
|---|---|
| 12 V Battery | 12.5 to 13.5 Vdc |
| Charging circuit | 13.8 to 14.8 Vdc |
Measure voltage at battery terminals with battery disconnected.
### Gate and Opener Maintenance:
1. Keep gates properly maintained. Grease hinges. Make sure gates remain level. Replace worn or damaged hardware. On gates over 250 lbs, grease ball bearing hinges at least 4 times annually (more if in a coastal area).
2. Service the gate opener regularly (make sure control box is OFF). Apply silicone spray to a soft, dry cloth and clean the push-pull tube at least once a month.
LPA 2000XLS Instruction Manual 26
## Page 37
# Repair Service
If your GTO 2000XLS Gate Operator is not operating properly, please follow the steps below:
1. First use the procedures found in the Troubleshooting Guide (see page 24).
2. Use the 24/7 Troubleshooting Wizard at http://support.gtoinc.com.
3. If you are unable to solve the problem, call the GTO Service Department at (800) 543-1236, or (850) 575-4144. Refer to the serial number (located on the right side of the battery box) and date of purchase when calling for assistance.
4. If repair or replacement of your gate operator is necessary, the Service Department will assign a Return Goods Authorization (RGA) number to you.
5. Once you have received your RGA# you are required to send in your original equipment for repair. Please refer to Manufacturers’ Limited Warranty for complete details. Securely pack the component(s) authorized for return to the factory. Include a copy of your sales receipt for the purchase of the product(s). Write the RGA number issued to you on the outside of the package in LARGE BOLD PRINT.
Ship the package(s) freight prepaid to: GTO, 3121 Hartsfield Road, Tallahassee, Florida, USA 32303.
**NOTE: Products returned to GTO without a Return Goods Authorization (RGA) number in LARGE BOLD PRINT on the outside of the package WILL NOT be accepted. Also, items returned to GTO freight collect WILL NOT be accepted.**
## GTO Technical Service
**8:00am–7:00pm • Monday–Friday (EST)**
> Figure: GTO Access Systems, LLC logo.
3121 Hartsfield Road • Tallahassee, Florida, USA 32303
800-543-4283 • Fax (850) 575-8912
Web site www.linearproaccess.com
24/7 Troubleshooting Wizard: http://support.gtoinc.com
> Figure: Small wizard mascot icon beside the 24/7 Troubleshooting Wizard information.
LPA 2000XLS Instruction Manual 27
## Page 38
# Accessories for 2000XLS
Please visit www.gtoaccess.com for photos and detailed descriptions of LPA Accessories. Or call 1-800-543-4283.
## POWERING ACCESSORIES
> Figure: Coiled low-voltage wire with two exposed conductor ends.
**Low Voltage Wire** [RB509]
The 16 gauge, stranded, dual conductor low voltage Wire is for connecting the AC powered transformer, solar panel or wired accessories to the system’s control board. This specially designed wire is UV treated, PVC coated, and ready for direct burial.
> Figure: Solar panel on a mounting post.
**Solar Panel Kits** [FM122/FM123]
If your gate operator is more than 1000 ft. away from an AC power outlet, you can choose to maintain the battery charge with the GTO Solar Panel Kit.
- 10 Watt Solar Panel Charging Kit [FM123]
- 5 Watt Solar Panel Charging Kit [FM122]
> Figure: Rectangular replacement battery.
**Additional/Replacement Battery** [RB500]
For additional battery power or replacement.
## “FROM VEHICLE” ENTRY AND EXIT ACCESSORIES
> Figure: Single-button transmitter and dual-button keychain transmitter.
**Transmitters** [RB741/RB742/RB743]
Purchase an additional transmitter for each vehicle in your family. The Two-Button Transmitter can be programmed to operate both your gate operator and a garage door opener using the Universal Receiver. Or it can be programmed to open two gate operator systems.
- Single Button Transmitter [RB741]
- Dual Button Transmitter [RB742]
- Three Button Transmitter [RB743]
> Figure: Universal antenna receiver with a long vertical antenna and connecting wire.
**Universal Receiver** [RB709U-NB]
The Universal Antenna Receiver gives you the ability to use one remote to activate your gate operator and your garage door opener. Connects to any brand garage door opener. Up to 100 ft. range.
> Figure: Digital keypad mounted on a curved protective housing; keypad buttons are shown.
**Digital Keypad** [F310]
Allow friends access to your property using an entry code that you provide. Program up to 25 entry codes for added security. Powered by three “AA” batteries (not included).
LPA 2000XLS Instruction Manual 28
## Page 39
> Figure: Gooseneck pedestal with a wireless entry intercom unit, including a keypad and base/receiver.
**Residential Wireless Entry Intercom** [F3100MBC]
Designed for added security to your automated gate with the ability to “speak to” and “screen” visitors safely from inside your home. Ideal for securing gate entrances while providing controlled access.
**Gooseneck Pedestal** [F100/F110]
Designed to mount digital keypads, wireless intercom systems, and other access control devices for your gate automation system. Available for in-ground or surface installations.
## “HANDS FREE” ENTRY & EXIT ACCESSORIES
> Figure: Driveway vehicle sensor consisting of a long cylindrical probe and coiled cable; wireless vehicle sensor consisting of a vertical sensor/transmitter on a stand, a coiled cable, and a separate horizontal component.
**Driveway Vehicle Sensor** [FM139]
Automatically activates gate operator “Hands-Free” when a vehicle exits the property. Electromagnetic sensor detects vehicles in motion.
- 50 ft. [FM139]
- 100 ft. [FM140]
- 150 ft. [FM141]
**Wireless Vehicle Sensor** [R4500]
Automatically activates gate operator “Hands-Free” when a vehicle exits the property. 100 ft. range between transmitter and receiver. Easy installation.
## LOCKING & SECURITY ACCESSORIES
> Figure: Automatic Gate Lock components, including a receiver bracket and lock labeled “GTO AUTOMATIC GATE LOCK.”
**Automatic Gate Lock** [FM144]
The #1 Accessory For Swing Gate Operators! Designed for added security in conjunction with GTO Automatic Gate Operators. The gate lock unlocks and locks automatically when the gate opens and closes. The perfect solution for high wind conditions.
> Figure: Bulldog Pedestrian Gate Lock components, including keypad, lock labeled “Bulldog,” and receiver bracket.
**Bulldog Pedestrian Gate Lock** [FM145]
Designed to mount on horizontal swing “walk through” wood, chain link, and metal pedestrian gates opening in or out. Ideal for securing pools, condominiums, schools and any pedestrian gate.
> Figure: Wireless driveway alarm sensor on a stand and indoor base station with antenna.
**Wireless Driveway Alarm** [R4450].
This device alerts you of vehicles entering your driveway (with or without an automated gate). The indoor base station signals you with a door chime when a vehicle passes the driveway sensor.
LPA 2000XLS Instruction Manual 29
## Page 40
# ADDITIONAL ACCESSORIES
> Figure: Pair of cylindrical photo beam devices.
**Photo Beams** [R4222]
Primary “through beam” photo beam device. Provides “non-contact” entrapment protection.
> Figure: Pin lock with a vertical locking pin and stacked metal body.
**Pin Lock** [FM345]
Use as a substitute for the clevis pin at the front mount of the PRO-SW2000XLS to prevent theft of the operator.
- Pin Lock 10-pack: ten Pin Locks keyed alike [FM345KA].
> Figure: Narrow rectangular unlit push-button control.
**Push Button Control** [RB101]
Wire this unlit push button directly to your gate operator for simple open/close/stop operation from up to 1000 ft. away. Use 16 gauge low-voltage wire.
> Figure: Replacement AC transformer with two plug prongs.
**Replacement Transformer** [RB502]
Standard 14 volt, 1430 mA AC transformer included with the 2000XLS to maintain battery charge.
> Figure: Gate grounding kit with coiled cable and connector ends.
**Gate Grounding Kit** [R4196]
The purpose of the grounding kit is to REDUCE THE RISK of damage to electronic equipment from lightning strikes. There is no protection or grounding system that can completely eliminate this risk.
## HARDWARE ACCESSORIES
> Figure: Flat Push To Open bracket with mounting holes.
**Push To Open Brackets** [347IH]
Required when the 2000XLS must push a gate open (arm extends to open), such as away from a sloping driveway or where space prevents gate from opening into the property (pull to open). Order two brackets for a dual swing gate installation.
> Figure: Column Mount Lock Receiver bracket.
**Column Mount Lock Receiver** [433IH]
For use with the Automatic Gate Lock or Bulldog Pedestrian Gate Lock when mounting on brick columns or applications with limited space.
LPA 2000XLS Instruction Manual 30
## Page 41
Notes
## Page 42
Notes
## Page 43
Notes
## Page 44
3121 Hartsfield Road • Tallahassee, Florida, USA 32303
800-543-4283 • Fax (850) 575-8912
Web site www.linearproaccess.com
24/7 Troubleshooting Wizard: http://support.gtoinc.com
> Figure: GTO ACCESS SYSTEMS, LLC logo. Text beneath: “3121 Hartsfield Road • Tallahassee, Florida, USA 32303”; “800-543-4283 • Fax (850) 575-8912”; “Web site www.linearproaccess.com”; and “24/7 Troubleshooting Wizard: http://support.gtoinc.com”. A small wizard-hat graphic appears beside the troubleshooting line.