Diablo Controls XLP-8-75 Free Exit Probe Kit, Vehicle Detector with 75 ft Lead-In
Opens the gate for vehicles leaving: a probe buried in one drilled hole replaces a saw-cut exit loop. Low-power XLP-8 detector, 75 ft lead-in.
- Ships next business day
- Exact carrier rate, no markup
- 5-year warranty
Delivery estimate shown at checkout.
Ships free with any of our gates - it rides in the crate
Ships for $11.00–$20.00 · 1–5 days in transit
Specifications
20 specifications
| Kit | |
|---|---|
| Part number | XLP-8-75 |
| Includes | XLP-8 detector + Free Exit Probe |
| Lead-in | 75 ft, attached to the probe |
| Probe | |
| Probe size | About 4½ × 1 in |
| Install hole | 1½–2 in wide, 6–12 in deep |
| Lead-in slot | ¼ in wide × 1 in deep |
| Placement | Mid-lane, 50–100 ft before the gate |
| Surfaces | Asphalt, concrete, pavers, gravel, dirt |
| Output | |
| Probe-mode output | 250 ms pulse on arrival |
| Relay | NO + NC, 1 A at 125 V AC / 60 V DC |
| Power | |
| Supply | 8–40 V DC or 8–28 V AC |
| Current draw | 0.85 mA idle, 30 mA max detecting |
| Settings | |
| Sensitivity | 9 levels + diagnostic mode |
| DIP switches | Frequency, loop/probe, boost, fail mode |
| Response time | About 160 ms |
| Environment | |
| Operating temperature | −35°F to 165°F |
| Humidity | Up to 95%, non-condensing |
| Safety | |
| Safety rating | Not a safety or obstruction sensor |
| Warranty | |
| Manufacturer warranty | 5 years |
| Fit | |
| Operator brand | Any |
Gates built in our San Jose shop and installed on real driveways.
Questions & Answers
How is this different from a saw-cut exit loop?
How is this different from a saw-cut exit loop?
You drill one hole about 1½ in wide and cut a single straight ¼ in slot to the edge of the drive, instead of cutting a whole loop pattern. Diablo notes the probe sits below traffic wear and pavement movement, so it tends to outlast a surface loop.
How big a hole do I drill?
How big a hole do I drill?
1½ to 2 in wide and 6 to 12 in deep. Set the probe upright, backfill with dry sand to 1 in below the surface, and cap it with loop sealant.
Does it work in gravel, dirt, asphalt or concrete?
Does it work in gravel, dirt, asphalt or concrete?
Yes. Diablo lists asphalt, concrete, cobblestone, poor pavement, dirt and gravel roads. In loose soil you can sleeve the probe in PVC pipe, never steel.
Where does the probe go, and how far from the gate?
Where does the probe go, and how far from the gate?
In the center of the exit lane, typically 50 to 100 ft before the gate so it's opening as the car arrives, and at least 15 ft from manhole covers or other metal lids. The 75 ft lead-in has to reach from there to the operator.
Can I put it beside the driveway instead of drilling the pavement?
Can I put it beside the driveway instead of drilling the pavement?
On drives under 11 ft wide, possibly, with less sensitivity; the probe can be tilted 45° toward the lane. Test with your smallest vehicle across the full width. If coverage falls short, add a second probe on its own XLP-8.
Will it open for people, bikes or animals?
Will it open for people, bikes or animals?
It's designed to sense vehicles, over a small point-sized zone. Diablo doesn't publish a rating for people, animals or bicycles, so test on site and adjust the sensitivity (default 5; lower it if needed).
Can it keep the gate from closing on a car?
Can it keep the gate from closing on a car?
No. In probe mode it only pulses when a vehicle arrives and can't sense a stopped car, and Diablo says it must never be used as an obstruction or safety sensor. Use monitored photo eyes or edges, or a saw-cut loop in presence mode, for that.
How do I wire it to a LiftMaster gate operator?
How do I wire it to a LiftMaster gate operator?
Power the XLP-8 from the operator's 24 V always-on accessory terminals and wire the relay COM and NO to the operator's EXIT input, which LiftMaster names for an exit probe. Don't use the operator's Exit Loop ports; those take LiftMaster's plug-in loop detector.
Does it work with other gate operators?
Does it work with other gate operators?
Yes. The relay contacts are isolated and have no polarity, so they connect to any operator's open or exit input, and the detector runs on 8–40 V DC or 8–28 V AC.
Is it OK on a solar gate?
Is it OK on a solar gate?
Yes. It draws 0.85 mA or less at idle (sensitivity 1–6) and about 30 mA only while the relay is active. Below 8 V the relay may not energize.
Is 75 ft of lead-in enough, and can I extend it?
Is 75 ft of lead-in enough, and can I extend it?
It usually sets how far from the operator the probe can go; Diablo also makes a 100 ft kit (XLP-8-100). If you must splice, use a junction box with soldered, weatherproofed joints, never wire nuts, and keep the pair tightly twisted.
How do I set up the detector?
How do I set up the detector?
Turn DIP switch 2 on for Probe. Probe mode is always fail-secure. Start at sensitivity 5 and move one step at a time. To check the probe itself, its two wires should read 1.5 to 7 ohms.
What is the warranty?
What is the warranty?
Diablo Controls covers its products for 5 years from the date of purchase.
About
- No saw-cut loop to install
- 0.85 mA idle, solar-friendly
- Detector + probe, 75 ft lead-in
The Diablo Controls XLP-8-75 gives an automatic gate free exit: a car driving out passes over a buried probe, and the gate opens on its own. Instead of grinding a wire loop into the driveway, you drill one small hole for the probe and cut a single narrow slot for its cable.
8–40 V DC / 8–28 V ACNO + NC relay, 1 A−35°F to 165°FSolar-friendly
The kit pairs Diablo's Free Exit Probe on a 75 ft lead-in with the XLP-8, an extreme-low-power detector that suits solar gates.
What's in the box
- XLP-8 vehicle detector with a pluggable 7-pin terminal
- Free Exit Probe with 75 ft of lead-in cable attached
What you'll still need
- A hammer or core drill for a 1½–2 in hole, 6–12 in deep
- A saw for a ¼ in × 1 in slot from the hole to the edge of the drive
- Dry sand to backfill the hole, plus loop sealant and backer rod
- 8–40 V DC or 8–28 V AC power, such as your operator's accessory output
- A weatherproof spot for the detector, usually inside the operator
- Optional: conduit from the edge of the drive to the operator
Where the probe goes
Diablo's manual puts the probe in the center of the exit lane, typically 50–100 ft before the gate, so the gate is already opening as the car arrives, and at least 15 ft from manhole covers or other metal lids. On a drive under 11 ft wide you can set it beside the pavement instead, with less sensitivity; test with your smallest vehicle. Wider drives can add a second probe on its own detector.
Probe or saw-cut loop?
| Probe kit | Saw-cut loop | |
|---|---|---|
| Cutting | 1 hole + 1 slot | Full loop |
| Holds open | No, pulse only | Yes (presence) |
| Solar draw | 0.85 mA idle | Per detector |
Wiring to a LiftMaster operator
- Power the detector. Feed the XLP-8 from the operator's always-on 24 V accessory terminals.
- Wire the relay to EXIT. Connect its relay COM and NO to the operator's two-terminal EXIT input, which LiftMaster's CSL24UL manual names for an exit probe. Don't connect the probe to the operator's loop-wire ports: those feed LiftMaster's own plug-in loop detector.
- Set probe mode. Set DIP switch 2 to Probe.
5-year warranty from the date of purchase, from Diablo Controls.
Buy with confidence
30-day returns
Return it within 30 days of delivery. Change-of-mind returns carry a 25% restocking fee; damage and defects are always on us.
- Priced live for your ZIP by USPS, UPS and FedEx. Ships free in the crate when ordered with a gate from the same seller.
- Free tech support
- Nationwide shipping
- Questions? Call (408) 260-5145